2901527
EM-RS485-GATEWAY-IFS
For more complex applications with Interface system devices (IFS), the extension module offers digital inputs and outputs for processing additional signals in the field. Easy connection to IFS gateway via the DIN rail connector as the slave. PLC logic set consisting of: plug-in basic logic module (BM2) and eight relay terminal blocks with Push-in connection (1 changeover contact, 250 V AC/DC, max.6 A). Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via Modbus/RS-485. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. PLC logic starter kit 3, consisting of: plug-in stand-alone logic module (SAM 2), eight relay output terminal blocks with Push-in connection (250 V AC/DC, max. 6 A), and micro USB programming cable. Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via PROFIBUS DP. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. Connecting cable, for connecting the controller to a PC for PC Worx and LOGIC+, USB A to micro USB B, 2 m in length. Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via EtherNet/IP™. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. Multi-functional memory block for the INTERFACE systemf for easy storage and backup of the configuration. Gateway for the connection of up to 32 INTERFACE system devices via PROFINET to a higher-level controller. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. Gateway for the connection of up to 32 INTERFACE system devices to a higher-level controller via CANopen. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. Gateway for the connection of up to 32 INTERFACE system devices via Modbus/TCP to a higher-level controller. The INTERFACE system devices are connected to the Gateway via DIN rail connectors, the DIN rail connectors are provided. Configuration package for the EMM .. IFS, comprising CONTACTRON-DTM-IFS, USB programming adapter, and user manual on CD. Multi-functional memory block with handle for the INTERFACE system; for easy storage and back up of the configuration. The voltage transducer set makes it possible to insert the electronic motor management module (EMM 3-.../500AC-IFS) in 690 V mains.
| Width: | 22.5 mm |
| Height: | 99 mm |
| Depth: | 114.5 mm |
| Ambient temperature (operation): | -25 °C ... 50 °C |
| Ambient temperature (storage/transport): | -35 °C ... 80 °C |
| Degree of protection: | IP20 |
| Rated control circuit supply voltage US: | 24 V DC -20 % ... +25 % |
| Rated control supply current IS: | 85 mA (plus load current of the outputs) |
| Protective circuit: | Reverse polarity protection |
| Number: | 8 |
| Rated actuating voltage UC: | 24 V DC ±20 % |
| Rated actuating current IC: | 3 mA |
| Protective circuit: | Reverse polarity protection |
| Designation: | Switching outputs |
| Number: | 4 |
| Residual voltage: | 1 V |
| Maximum switching voltage: | 23 V DC (UB - Uresid. of the output) |
| Max. switching current: | 500 mA |
| Protective circuit: | Parallel protection against polarity reversal, pay attention to the fuse Fusing with max. 8 A F-fuse |
| Operating mode: | 100% operating factor |
| Mounting position: | any |
| Assembly instructions: | In rows with zero spacing |
| Mounting type: | DIN rail mounting |
| Housing material: | Polyamide PA non-reinforced |
| Color: | green |
| Interface 1: | Interface-System |
| Serial transmission speed: | 76.8 kbps |
| Connection method: | DIN rail bus connectors |
| Interface 2: | RS-485 |
| Serial transmission speed: | 9.6 k ... 115 kbaud |
| Connection method: | MSTB plug entry |
| Connection name: | Supply |
| Connection method: | Screw connection |
| Stripping length: | 8 mm |
| Screw thread: | M3 |
| Conductor cross section solid: | 0.2 mm² ... 2 mm² |
| Conductor cross section flexible: | 0.2 mm² ... 2.5 mm² |
| Conductor cross section AWG: | 24 ... 12 |
| Connection name: | Programming connection |
| Connection method: | S-PORT (socket) |
| Number of connections: | 1 |
| Number of positions: | 12 |
| Connection name: | INTERFACE system |
| Connection method: | DIN rail bus connectors |
| Number of connections: | 1 |
| Number of positions: | 5 |
| Connection name: | RS-485 |
| Connection method: | Screw connection |
| Number of connections: | 1 |
| Number of positions: | 5 |
| Standards/regulations: | EN 50178 |
| Pollution degree: | 2 |
| Overvoltage category: | III |
| REACh SVHC: | Lead 7439-92-1 |
| China RoHS: | Environmentally Friendly Use Period = 50 years |
| eCl@ss 10.0.1: | 27242608 |
| eCl@ss 4.0: | 27371100 |
| eCl@ss 4.1: | 27371100 |
| eCl@ss 5.0: | 27371600 |
| eCl@ss 5.1: | 27371600 |
| eCl@ss 6.0: | 27242600 |
| eCl@ss 7.0: | 27242608 |
| eCl@ss 8.0: | 27242608 |
| eCl@ss 9.0: | 27242608 |
| ETIM 3.0: | EC001604 |
| ETIM 4.0: | EC001604 |
| ETIM 5.0: | EC001604 |
| ETIM 6.0: | EC001604 |
| ETIM 7.0: | EC001604 |
| UNSPSC 6.01: | 30211915 |
| UNSPSC 7.0901: | 39121514 |
| UNSPSC 11: | 39121514 |
| UNSPSC 12.01: | 39121514 |
| UNSPSC 13.2: | 32151602 |
| UNSPSC 18.0: | 32151602 |
| UNSPSC 19.0: | 32151602 |
| UNSPSC 20.0: | 32151602 |
| UNSPSC 21.0: | 32151602 |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 0,00 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |