| Length of cable: | 1.5 m |
| Ambient temperature (operation): | -25 °C ... 85 °C (Plug / socket) |
| Degree of protection: | IP65 |
| Rated current at 40°C: | 12 A |
| Rated voltage: | 690 V AC |
| Number of positions: | 4 |
| Color handle area: | black |
| Insulation resistance: | ≥ 100 MΩ |
| Coding: | S power |
| Standards/regulations: | M12 connector IEC 61076-2-111 |
| Status display: | No |
| Protective circuit/component: | unwired |
| Overvoltage category: | III |
| Degree of pollution: | 3 |
| Insertion/withdrawal cycles: | > 100 |
| Torque: | 0.4 Nm (M12 connector) |
| Flammability rating according to UL 94: | V0 |
| Contact material: | CuZn |
| Contact surface material: | Ni/Au |
| Contact carrier material: | PA |
| Material of grip body: | PP |
| Material, knurls: | Zinc die-cast, nickel-plated |
| Standards/specifications: | M12 connector IEC 61076-2-111 |
| Flammability rating according to UL 94: | V0 |
| Cable type: | PUR halogen-free orange shielded |
| Cable type (abbreviation): | PUR |
| Cable abbreviation: | 9YSLC11Y-JZ |
| UL AWM style: | 20234 / 10492 (80°C/1000 V) |
| Conductor cross section: | 4x 1.5 mm² |
| AWG power supply: | 16 |
| Conductor structure, voltage supply: | 78x 0.15 mm |
| Core diameter including insulation: | ≤ 2.5 mm |
| Thickness, insulation: | 0.4 mm |
| Wire colors: | Black 1, black 2, black 3, green/yellow |
| Overall twist: | 4 wires optimally twisted |
| Shielding: | Tinned copper-braided shield, approx. 85% covering |
| External sheath, color: | orange RAL 2003 |
| Outer sheath thickness: | 1.2 mm |
| External cable diameter D: | 9.7 mm ±0.3 mm |
| Minimum bending radius, fixed installation: | 5 x D |
| Minimum bending radius, flexible installation: | 7.5 x D |
| Number of bending cycles: | 4000000 |
| Minimum bending radius, drag chain applications: | 10 x D |
| Traversing path: | 10 m |
| Traversing rate: | 3 m/s |
| Acceleration: | 10 m/s² |
| Torsion force: | ± 25 °/m |
| Outer sheath, material: | PUR |
| Material conductor insulation: | PP |
| Conductor material: | Bare Cu litz wires |
| Insulation resistance: | ≥ 10 MΩ*km (at 20 °C) |
| Conductor resistance: | ≤ 13.3 Ω/km (at 20 °C) |
| Nominal voltage, cable: | 1000 V AC |
| Test voltage, cable: | 4260 V AC (5 min.) |
| Flame resistance: | according to EN 60332-1-2 |
| Halogen-free: | according to VDE 0282-13 Appendix C |
| Resistance to oil: | in accordance with DIN EN 60811-2-1 |
| Other resistance: | UV resistant |
| Ambient temperature (operation): | -40 °C ... 90 °C (cable, fixed installation) |
| REACh SVHC: | Lead 7439-92-1 |
| China RoHS: | Environmentally Friendly Use Period = 50 years |
| eCl@ss 10.0.1: | 27060311 |
| eCl@ss 4.0: | 27140800 |
| eCl@ss 4.1: | 27140800 |
| eCl@ss 5.0: | 27143400 |
| eCl@ss 5.1: | 27143400 |
| eCl@ss 6.0: | 27279200 |
| eCl@ss 7.0: | 27279218 |
| eCl@ss 8.0: | 27279218 |
| eCl@ss 9.0: | 27060311 |
| ETIM 3.0: | EC002061 |
| ETIM 4.0: | EC001855 |
| ETIM 5.0: | EC001855 |
| ETIM 6.0: | EC001855 |
| ETIM 7.0: | EC001855 |
| UNSPSC 6.01: | 31251501 |
| UNSPSC 7.0901: | 31251501 |
| UNSPSC 11: | 31251501 |
| UNSPSC 12.01: | 31251501 |
| UNSPSC 13.2: | 31251501 |
| UNSPSC 19.0: | 31251501 |
| UNSPSC 20.0: | 31251501 |
| UNSPSC 21.0: | 31251501 |
| ECCN: | |
| Kraj pochodzenia: | PL |
| EAN: | |
| Waga: | 0,25 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |