904966
NBB10-30GK60-AR-1M
Inductive sensor
Series: Relay output, Housing material: PBT, Output type: Relay output, Installation: flush, Type of voltage: DC, Connection type: 1-meter cable, PVC heavy jacket, 5-conductor, #18 AWG, Degree of protection: IP68fa
| Switching function: | change-over contact |
| Output type: | relay |
| Rated operating distance: | 10 mm |
| Installation: | flush |
| Output polarity: | DC |
| Reduction factor rAl: | 0.4 |
| Reduction factor rCu: | 0.3 |
| Reduction factor r304: | 0.85 |
| Output type: | Relay output |
| Mechanical life: | No load: 2 x 107 operations Full load: 1 x 105 switching cycles |
| Operating voltage: | 10 ... 30 V DC |
| Switching frequency: | 20 Hz |
| Hysteresis: | approx. 10 % |
| Reverse polarity protection: | yes |
| Short-circuit protection: | no |
| Operating current: | ≤ 50 mA |
| Switching state indicator: | LED, yellow |
| Switching voltage: | max 28 V DC |
| Switching current: | max 6 A DC resistive load |
| Switching power: | max 180 W |
| UL approval: | cULus Listed, General Purpose |
| CSA approval: | cCSAus Listed, General Purpose |
| Ambient temperature: | -40 ... 70 °C (-40 ... 158 °F) |
| Connection type: | 1-meter cable, PVC heavy jacket, 5-conductor, #18 AWG |
| Core cross-section: | 0.75 mm2 |
| Housing material: | PBT |
| Sensing face: | PBT |
| Degree of protection: | IP68 |
| ECCN: | |
| Kraj pochodzenia: | ID |
| EAN: | |
| Waga: | 0,00 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |