Pepperl+Fuchs 419077

RLK91-54-RT/31/59/115

Retroreflective sensor

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Concentration on the essentials is the hallmark of the 91 series. As ac/dc supply devices, these economical, reliable and easy-to-use photoelectric sensors can be used almost universally. Their narrow design means that they can be used in any environment. Retroreflective sensor for single-beam closing edge protection, Narrow housing suitable for small gaps, Sturdy plastic housing, Various possibilities for mounting, Version with red light, Housing: Luran®, Light type: modulated visible red light, Signal output: Weak current relay, 1 alternator, Degree of protection: IP65fa. The single-beam photoelectric sensors of the 91 series are suitable for closing-edge monitoring for elevators, barriers and doors, as well as for object detection and object tracking in material handling systems.

Parametry techniczne

Effective detection range: 0 ... 4 m
Reflector distance: 0.2 ... 4000 mm
Threshold detection range: 8 m
Reference target: H85-2 reflector
Light source: LED
Light type: modulated visible red light
Diameter of the light spot: approx. 160 mm at a distance of 4000 mm
Angle of divergence: approx. 2.5 °
Ambient light limit: 90000 Lux
MTTFd: 1083.4 a
Function indicator: LED red, flashes when falling short of the stability control
Rated operating voltage: 96 ... 240 V AC
Power consumption: 12 VA
Contact ratings: according to UL 508 1/8 HP, 1.9 FLA, 240 V AC, Pilot Duty Code D150 6,000 1.5 FLA, 120 V AC, Pilot Duty 30,000 0.8 FLA, 240 V AC, Pilot Duty 30,000
Switching type: dark on
Signal output: Weak current relay, 1 alternator
Switching voltage: max. 240 V AC
Switching current: 2.5 A / 240 V AC
Switching power: max. 120 W / 600 VA
Switching frequency: 25 Hz
Response time: 20 ms
Product standard: EN 60947-5-2
EAC conformity: TR CU 020/2011 TR CU 004/2011
UL approval: cULus For overcurrent protection, install a fuse with a rated current of max. 5 A and min. 240 V AC
CCC approval: Certified by China Compulsory Certification (CCC)
Ambient temperature: -20 ... 55 °C (-4 ... 131 °F)
Storage temperature: -20 ... 75 °C (-4 ... 167 °F)
Degree of protection: IP65
Connection: 5 m fixed cable
Material: Housing: Luran®
Material: Optical face: glass pane
Mass: 100 g

Parametry logistyczne

ECCN:
Kraj pochodzenia: SG
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m