419061
RL91-6-IR/25/38a/115
Retroreflective sensor
Retroreflective sensor for single-beam closing edge protection, Narrow housing suitable for small gaps, Sturdy plastic housing, Various possibilities for mounting, Version with infrared light, Housing: Luran®, Light type: modulated infrared light, Operating voltage: 12 .. 30 V DC / 18 .. 28 V AC, Signal output: Weak current relay, 1 alternator, Degree of protection: IP65fa. Concentration on the essentials is the hallmark of the 91 series. As ac/dc supply devices, these economical, reliable and easy-to-use photoelectric sensors can be used almost universally. Their narrow design means that they can be used in any environment. The single-beam photoelectric sensors of the 91 series are suitable for closing-edge monitoring for elevators, barriers and doors, as well as for object detection and object tracking in material handling systems.
| Effective detection range: | 0 ... 6 m |
| Reflector distance: | 0 ... 6 m |
| Threshold detection range: | 9 m |
| Reference target: | H85-2 reflector |
| Light source: | LED |
| Light type: | modulated infrared light |
| Diameter of the light spot: | approx. 230 mm at a distance of 6000 mm |
| Angle of divergence: | approx. 2.5 ° |
| Ambient light limit: | 90000 Lux |
| MTTFd: | 1083.4 a |
| Function indicator: | LED red, flashes when falling short of the stability control |
| Operating voltage: | 12 ... 30 V DC / 18 ... 28 V AC |
| No-load supply current: | < 100 mA |
| Switching type: | light on |
| Signal output: | Weak current relay, 1 alternator |
| Switching voltage: | ≤ 55 V AC / 24 V DC |
| Switching current: | 1 A /24 V DC, 0.5 A /110 V AC |
| Switching power: | max. 24 W / 55 VA |
| Switching frequency: | 25 Hz |
| Response time: | 20 ms |
| Product standard: | EN 60947-5-2 |
| UL approval: | cULus For overcurrent protection, install a fuse with a rated current of max. 5 A and min. 55 V AC |
| CCC approval: | CCC approval / marking not required for products rated ≤36 V |
| Ambient temperature: | -20 ... 55 °C (-4 ... 131 °F) |
| Storage temperature: | -20 ... 75 °C (-4 ... 167 °F) |
| Degree of protection: | IP65 |
| Connection: | 5 m fixed cable |
| Material: Housing: | Luran® |
| Material: Optical face: | Luran® |
| Mass: | 100 g |
| Note: | Safety fuse ≤ 315 mA (slow-blow) according to IEC 60127-2 Sheet 1 Recommendation: after a short circuit, check that the device is functioning correctly. |
| ECCN: | |
| Kraj pochodzenia: | VN |
| EAN: | |
| Waga: | 0,00 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |