Pepperl+Fuchs 283822

HD2-GTR-4PA.PN

PROFINET Power Hub, Gateway Module

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Gateway PROFINET RT to 4 x PROFIBUS PA segments, Up to 32 devices per PROFIBUS PA segment, Installation in Zone 2/Class I, Div. 2, Ring and system redundancy, Integrated webserver for diagnosticspa. The PROFINET to PROFIBUS PA gateway integrates communication of 4 PA segments into PROFINET I/O systems. The gateway is part of the FieldConnex. Power Hub system. The gateway operates with power supply modules connected to the same or a separate motherboard. The gateway provides a PA master for each segment and thus enables short bus cycle times. One single gateway supports S2 system redundancy and ring redundancy. A complete toolchain supports the engineering for system integration. A gateway device type manager (DTM) and a webserver enable access to both status and diagnostics of the gateway. The gateway DTM enables communication for parameterization, diagnostics, and status information to PROFIBUS PA devices through vendors’ DTMs. A library of STEP 7 software modules for integration into Siemens PCS7 is available. The PROFINET gateway is an ideal solution for new plants and for upgrading existing PROFIBUS PA installations from PROFIBUS DP to PROFINET.

Parametry techniczne

Design / Mounting: Motherboard based
Rated voltage: 19.2 ... 35 V SELV/PELV
Rated current: typ. 135 mA
Power dissipation: approx. 3.5 W
Number of segments: 4
Number of devices per segment: max. 32
Fieldbus type: PROFIBUS PA
Number of ports: 2
Protocol: PROFINET
Ethernet Interface: Connector , 2x RJ45
Transfer rate: 100 MBit/s
Redundancy: Ring (MRP) , System S2
LED ETH1 LINK 2: green: link status
LED ETH1 ACT: yellow: activity status
LED ETH2 LINK: green: link status
LED ETH2 ACT: yellow: activity status
LED ERR: red 2 Hz flashing: Ethernet error
LED Seg 1...4: red 2 Hz flashing: PA error, red and LED DP/ERR red: MAU error
LED PWR: green: Power on
LED DP/ERR: red 2 Hz flashing: DP error ; red: Hardware error
LED Red.: yellow: redundant operation primary device ; yellow 2 Hz flashing: synchronization or redundancy not available
CH/PROFIBUS DP: functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff
PROFIBUS DP/Supply: functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff
CH/CH: functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff
CH/Ethernet: functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff
All circuits/FE: functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff
Ethernet/Supply: functional insulation acc. to IEC 61010, rated insulation voltage 50 Veff
Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1:2013
Electromagnetic compatibility: NE 21:2011
Degree of protection: IEC 60529
Fieldbus standard: IEC 61158-2
Shock resistance: EN 60068-2-27
Vibration resistance: EN 60068-2-6
Ambient temperature: -40 ... 60 °C (-40 ... 140 °F) vertically mounted , -40 ... 70 °C (-40 ... 158 °F) horizontally mounted
Storage temperature: -40 ... 85 °C (-40 ... 185 °F)
Relative humidity: < 95 % non-condensing
Shock resistance: 15 g 11 ms
Vibration resistance: 1 g , 10 ... 150 Hz
Pollution degree: max. 2, according to IEC 60664
Corrosion resistance: acc. to ISA-S71.04-1985, severity level G3
Housing material: Polycarbonate
Housing width: 40 mm
Housing height: 106 mm
Housing depth: 128 mm
Degree of protection: IP20
Mass: 250 g
Mounting: motherboard mounting
Statement of conformity: TÜV 15 ATEX 7735 X
Electromagnetic compatibility: Group, category, type of protection, temperature class: II 3 G Ex ec IIC T4 Gc
Directive conformity: Directive 2014/34/EU: EN 60079-0:2012 , EN 60079-7:2015 , EN 60079-11:2012
IECEx approval: IECEx TUR 16.0007X
Directive conformity: Approved for: Ex ec IIC T4 Gc
Marine approval: pending

Parametry logistyczne

ECCN:
Kraj pochodzenia: SG
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m