276400
S1SD-1TI-1U
Temperature Converter
This signal conditioner provides the galvanic isolation between field circuits and control circuits. 1-channel signal conditioner, 24 V DC supply, Thermocouple, RTD, potentiometer or mV input, Input for PTC thermistor, Current and voltage output, Line fault (LFD) and sensor burnout detection, Accuracy 0.1 %, Connection via screw terminalspa. The device has an input for signals of the following field devices:, resistance thermometers, thermocouples. PTC thermistors, potentiometers, voltage sources, field device with its own characteristic. The device provides the following standard signals at the output:. 0/2 mA ... 10 mA signal. 0/4 mA ... 20 mA signal. 0/1 V ... 5 V signal. 0/2 V ... 10 V signal. This device has an integrated cold junction compensation. You can also implement external cold junction compensation. A fault is signalized by LEDs. The device is easily configured by the use of DIP switches. The Teach-In function can be used to teach in the potentiometer start value and end value. The device can be powered via terminals or Power Bus.
| Signal type: | Analog input |
| Operation time: | MTBF: 353 a acc. to SN 29500 stationary continuous operating, average ambient temperature 40 °C (104 °F) |
| Connection: | Power Bus or terminals 1-, 2+ |
| Rated voltage: | 16.8 ... 31.2 V DC |
| Power dissipation: | 0.7 W |
| Power consumption: | 0.8 W |
| Programming interface: | programming socket |
| Connection side: | field side |
| Connection: | terminals 5, 6, 7, 8 |
| PTC: | type KT, KTY, ST |
| : Measuring current: | approx. 200 µA |
| : Types of measuring: | 2-, 3-, 4-wire connection |
| : Lead resistance: | ≤ 100 Ω per line |
| : Measurement loop monitoring: | sensor breakage, lead breakage, short circuit |
| RTD: | type Pt100, Pt200, Pt500, Pt1000 (EN 60751: 1995) type Ni100, Ni200, Ni500, Ni1000 (DIN 43760) |
| : Measuring current: | approx. 200 µA |
| : Types of measuring: | 2-, 3-, 4-wire connection |
| : Lead resistance: | max. 100 Ω per line |
| : Measurement loop monitoring: | sensor breakage, lead breakage, short circuit |
| Thermocouples: | type B, E, J, K, N, S, T (IEC 584-1:1995) type L, U (DIN 43710:1985) type C, D (ASTM E988) |
| : Cold junction compensation: | external (Pt100) and internal , manually |
| : Lead resistance: | max. 10 kΩ |
| : Measurement loop monitoring: | sensor breakage, lead breakage |
| Resistor: Measurement range: | 0 ... 5 kΩ |
| Potentiometer: | 0.2 ... 50 kΩ |
| Resistor: Types of measuring: | 3-wire connection |
| Voltage: | -100 ... 100 mV -1000 ... 1000 mV |
| Input resistance: | ≥ 1 MΩ |
| Connection side: | control side |
| Connection: | terminals 3-, 4+ |
| Analog voltage output: | 0/1 ... 5 V , 0/2 ... 10 V , load ≥ 2 kΩ |
| Analog current output: | 0/2 ... 10 mA, 0/4 ... 20 mA, load ≤ 600 Ω |
| Ripple: | ≤ 10 mV eff |
| Fault signal: | downscale or upscale |
| Accuracy: | max. 0.1 % of full-scale value |
| Measuring time: | ≤ 300 ms |
| Deviation: RTD: | < 0.1 K/0.05 % of the measured value |
| Deviation: Thermocouples: | < 0.3 K/0.1 % of the measured value |
| Deviation: Voltage: | < 0.1 % of the measured value |
| Deviation: Potentiometer: | < 0.02 % of the measured value |
| Influence of ambient temperature: | < 100 ppm/K of full-scale value |
| Output/power supply: | safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min |
| Input/Other circuits: | safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min |
| Control elements: | DIP-switch keys |
| Configuration: | via DIP switches via keys via software |
| Labeling: | space for labeling at the front |
| Electromagnetic compatibility: Directive 2014/30/EU: | EN 61326-1:2013 (industrial locations) |
| Degree of protection: | IEC 60529:2001 |
| Protection against electrical shock: | EN 61010-1:2010 |
| Ambient temperature: | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature: | -40 ... 85 °C (-40 ... 185 °F) |
| Damaging gas: | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
| Degree of protection: | IP20 |
| Connection: | screw terminals |
| Core cross-section: | 0.5 ... 2.5 mm2 (20 ... 14 AWG) |
| Mass: | approx. 70 g |
| Dimensions: | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) , housing type S1 |
| Mounting: | on 35 mm DIN mounting rail acc. to EN 60715:2001 |
| Certificate: | DEMKO 16 ATEX 1750X |
| Electromagnetic compatibility: Marking: | II 3G Ex nA IIC T4 Gc |
| Directive conformity: Directive 2014/34/EU: | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 |
| UL approval: | E106378 |
| IECEx approval: | IECEx UL 16.0116X |
| Directive conformity: Approved for: | Ex nA IIC T4 Gc |
| Supplementary information: | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 0,00 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |