276338
FB6211BR
Digital Output
The digital output features 4 independent channels. 4-channel, Outputs Ex ia, Installation in suitable enclosures in Zone 1, Module can be exchanged under voltage (hot swap)pa. The device can be used to drive solenoids, sounders, or LEDs. Open and short-circuit line faults are detected. The outputs are galvanically isolated from the bus and the power supply.
| Occupied slots: | 2 |
| Connection: | backplane bus / 24 V booster via wire ends |
| Rated voltage: | 12 V DC , only in connection with the power supplies FB92** |
| Input voltage range: | 18.5 ... 32 V DC (SELV/PELV) booster voltage |
| Power dissipation: | 3 W |
| Power consumption: | 0.15 W |
| Connection: | backplane bus |
| Interface: | manufacturer-specific bus to standard com unit |
| Number of channels: | 4 |
| Suitable field devices: Field device: | Solenoid Valve |
| Suitable field devices: Field device [2]: | audible alarm |
| Suitable field devices: Field device [3]: | visual alarm |
| Connection: | channel I: 9+, 10-; channel II: 11+, 12-; channel III: 13+, 14-; channel IV: 15+, 16- |
| Current limit: | 40 mA |
| Internal resistor: | max. 320 Ω |
| Open loop voltage: | 24.5 V |
| Line fault detection: | can be switched on/off for each channel via configuration tool also when turned off (every 2.5 s the valve is turned on for 2 ms) |
| Suitable field devices: Short-circuit: | < 100 Ω |
| Suitable field devices: Open-circuit: | > 15 kΩ |
| Response time: | 10 ms (depending on bus cycle time) |
| Watchdog: | within 0.5 s the device goes in safe state, e.g. after loss of communication |
| Reaction time: | 10 s |
| LED indication: | LED green: supply LED red: line fault , red flashing: communication error |
| Coding: | optional mechanical coding via front socket |
| Electromagnetic compatibility: Directive 2014/30/EU: | EN 61326-1 |
| Electromagnetic compatibility: | NE 21 |
| Degree of protection: | IEC 60529 |
| Environmental test: | EN 60068-2-14 |
| Shock resistance: | EN 60068-2-27 |
| Vibration resistance: | EN 60068-2-6 |
| Damaging gas: | EN 60068-2-42 |
| Relative humidity: | EN 60068-2-56 |
| Ambient temperature: | -20 ... 60 °C (-4 ... 140 °F) |
| Storage temperature: | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity: | 95 % non-condensing |
| Shock resistance: | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance: | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas: | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
| Degree of protection: | IP20 (module) , a separate housing is required acc. to the system description |
| Connection: | removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2) |
| Mass: | approx. 750 g |
| Dimensions: | 57 x 107 x 132 mm (2.2 x 4.2 x 5.2 inch) |
| EU-Type Examination Certificate: | PTB 97 ATEX 1074 U |
| Electromagnetic compatibility: Marking: | II 2(1) G Ex d [ia Ga] IIC Gb II (1) D [Ex ia Da] IIIC |
| Output: Voltage: | 27.8 V |
| Output: Current: | 107 mA |
| Output: Power: | 744 mW |
| Output: Internal capacitance: | 2.5 nF |
| Output: Internal inductance: | 0 mH |
| Galvanic isolation: Output/power supply, internal bus: | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V |
| Directive conformity: Directive 2014/34/EU: | EN 60079-0:2009 EN 60079-1:2007 EN 60079-11:2007 EN 60079-26:2007 EN 61241-11:2006 |
| ATEX approval: | PTB 97 ATEX 1075 ; PTB 97 ATEX 1074 U |
| EAC approval: | Russia: RU C-IT.MIII06.B.00129 |
| Marine approval: Lloyd Register: | 15/20021 |
| Marine approval: DNV GL Marine: | TAA0000034 |
| Marine approval: American Bureau of Shipping: | T1450280/UN |
| Marine approval: Bureau Veritas Marine: | 22449/B0 BV |
| System information: | The module has to be mounted in appropriate backplanes and housings (FB92**) in Zone 1, 2, 21, 22 or outside hazardous areas (gas or dust). Here, observe the corresponding EC-type examination certificate. |
| Supplementary information: | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 0,00 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |