Pepperl+Fuchs 272955

KCD2-STC-Ex1.2O

SMART Transmitter Power Supply

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

This isolated barrier is used for intrinsic safety applications. 1-channel isolated barrier, 24 V DC supply (Power Rail), Input for 2-wire SMART transmitters and current sources, Signal splitter (1 input and 2 outputs), Dual output 0/4 mA .. 20 mA or 0/1 V .. 5 V, Terminal blocks with test sockets, Up to SIL 2 acc. to IEC 61508pa. The device supplies 2-wire transmitters in the hazardous area, and can also be used with current sources. It transfers the analog input signal to the safe area as two isolated output signals. Bi-directional communication is supported for SMART transmitters that use current modulation to transmit data and voltage modulation to receive data. The output is selected as a current source, current sink, or voltage source via switches. Test sockets for the connection of HART communicators are integrated into the terminals of the device.

Parametry techniczne

Signal type: Analog input
Safety Integrity Level (SIL): SIL 2
Connection: Power Rail or terminals 9+, 10-
Rated voltage: 18 ... 30 V DC
Ripple: within the supply tolerance
Power dissipation: approx. 1.4 W at 20 mA transfer current, 250 Ω in both outputs
Power consumption: 2 W
Connection side: field side
Connection: terminals 1+, 2- (sink); 3+, 4- (source)
Input signal: 0/4 ... 20 mA
Voltage drop: terminals 3, 4: ≤ 6.1 V at 20 mA
Short-circuit current: terminals 1+, 2-: 25 mA
Input resistance: terminals 1+, 2-: max. 500 Ω (BRAIN) (250 Ω load)
Available voltage: terminals 1+, 2-: ≥ 16 V at 20 mA , ≥ 18.5 V at 4 mA
Connection side: control side
Connection: source: terminals 5-, 6+; 7-, 8+ sink: terminals 5+, 6-, 7+, 8-
Load: channel 1: 0 ... 500 Ω (20 mA)/> 1 MΩ (5 V) channel 2: 0 ... 500 Ω (20 mA)/> 1 MΩ (5 V)
Output signal: 0/4 ... 20 mA or 0/1 ... 5 V
Ripple: max. 50 µA rms
Deviation: Iout < 20 µA (0.1 %); Vout < 10 mV (0.2 %) incl. calibration, linearity, hysteresis and fluctuation of supply voltage, at 20 °C (68 °F), 0/4 ... 20 mA, 0/1 ... 5 V
: Influence of ambient temperature: current output: 0.25 µA/K voltage output: 80 µV/K
Frequency range: field side into the control side: bandwidth with 0.5 Vpp signal 0 ... 6 kHz (-3 dB) control side into the field side: bandwidth with 0.5 Vpp signal 0.3 ... 6 kHz (-3 dB)
Settling time: 6 ms
Rise time/fall time: 2 ms
Output/power supply: functional insulation, rated insulation voltage 50 V AC
Output/Output: functional insulation, rated insulation voltage 50 V AC
Display elements: LED
Control elements: DIP-switch
Configuration: via DIP switches
Labeling: space for labeling at the front
Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1:2013 (industrial locations)
Electromagnetic compatibility: NE 21:2012 EN 61326-3-2:2008
Degree of protection: IEC 60529:2001
Protection against electrical shock: UL 61010-1:2012
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
Degree of protection: IP20
Connection: screw terminals
Mass: approx. 100 g
Dimensions: 12.5 x 114 x 122 mm (0.5 x 4.5 x 4.8 inch) , housing type A2
Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001
EU-type examination certificate: BASEEFA 13 ATEX 0077 X
Electromagnetic compatibility: Marking: II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I
Electromagnetic compatibility: Input: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Supply: Maximum safe voltage: 250 V (Attention! The rated voltage can be lower.)
Equipment: terminals 1+, 2-
Supply: Voltage Uo: 25.2 V
Supply: Voltage Uq: 28.2 V
Supply: Current Io: 93 mA
Supply: Power Po: 656 mW
Supply: Internal capacitance Ci: 10 nF
Supply: Internal inductance Li: 0 mH
Equipment: terminals 3+, 4-
Supply: Voltage Ui: 30 V
Supply: Current Ii: 115 mA
Supply: Power Pi: 700 mW
Supply: Voltage Uo: 5 V
Supply: Current Io: 6.8 mA
Supply: Power Po: 1.6 mW
Output: Maximum safe voltage: 250 V (Attention! The rated voltage can be lower.)
Certificate: BASEEFA 13 ATEX 0078 X
Output: Marking: II 3G Ex nA II T4 Gc [device in zone 2]
Galvanic isolation: Input/Output: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Galvanic isolation: Input/power supply: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
UL approval: Control drawing: 116-0380 (cULus)
IECEx approval: IECEx BAS 13.0043X
UL approval: Approved for: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Note: Both output loads must be connected to ensure complete and correct operation within the technical specification.
Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.
Optional accessories: - power feed module KFD2-EB2(.R4A.B)(.SP) - universal power rail UPR-03(-M)(-S) - profile rail K-DUCT-BU(-UPR-03)

Parametry logistyczne

ECCN:
Kraj pochodzenia: SG
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m