Pepperl+Fuchs 272713

VBA-4E3A-G20-ZEL/M1L-P2

AS-Interface I/O module

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

The AS-Interface connecting module is a field module with two sensor inputs and two electronic outputs for controlling DC roller motors of the type Interroll EC310 and Rulmeca BL3 or compatible. G20 motor control module for Interroll EC310 and EC5000, Rulmeca BL3 and Itoh Denki PM500XKfa. The compact housing can be installed directly in support profiles or conduits. The connection to the AS-Interface network and power supply is made using the AS-Interface flat cable and insulation-piercing technology. The pivoted flat cable guide is secured using a snap fit. No tools are required. The sensor inputs and motor outputs are connected via cable outputs with M8 round plug connectors (inputs 4-pole female cordset with knurled thumb screw, outputs 5-pole snap-on female cordset). Power for the inputs and motors is provided by the external auxiliary voltage UAUX. The current switching state of the sensor inputs is indicated by the IN LEDs. The FUSE LEDs show that the power supply is applied to both motors. The MOT LEDs indicate when the motors are in operation (stop/operation). The DIR LED indicates the status of the rotation signal. The activation of the fault signal by a motor is displayed with the ERR LEDs. The motors can be switched on and off individually by means of AS-Interface databits D0 and D1. D2 controls the rotation signal. The AS-Interface parameters P0 .. P2 select the voltage for the speed signal. The rotation and speed apply to both motors. A start/stop ramp can be set for the speed signal for the controlled acceleration and stopping of the motors. The ramp duration can be selected from eight default values and can be configured over a defined sequence of data and parameters. The ramp selected in this way is saved permanently and is activated automatically after each power-on. The number of the ramp is displayed by a short flash of the ERR2, IN1, and IN2 LEDS in binary code. If the ramp number is set as 0 (no ramp), the six LEDs MOT1 to IN2 flash to show this. The ramp is not effective if the rotation signal is switched while the motor is running. In other words, the reversal of rotation direction occurs immediately. Note:. The communication monitor of the module deactivates the outputs if there is no communictaion between the AS-Interface and the module for more than 40 ms. The IN1 and IN2 inputs suppress impulses of less than than 2 ms. A signal indicating an overload of the input supply , an overload of the speed signal, or the absence of the external auxiliary voltage is also transmitted to the AS-Interface master via the "peripheral fault" function. Communication via the AS-Interface continues.

Parametry techniczne

Slave type: A/B slave
AS-Interface specification: V3.0
Required master specification: ≥ V2.1
UL File Number: E223772 "For use in NFPA 79 Applications only"
MTBF: 98 a
Compatible roller motors: Interroll EC310, Interroll EC5000 (24V: 20W / 35W / 50W), Itoh Denki PM500XK, Rulmeca BL3
LED FAULT: error display; LED red red: communication error or address is 0 red flashing: overload of sensor supply or speed signal overload or external auxiliary voltage UAUX missing
LED ERR: Motor fault: 2 LED yellow
LED PWR: AS-Interface voltage; green LED green: voltage OK green flashing: address 0 or sensor supply overload or speed signal overload or external auxiliary voltage UAUX missing
LED AUX: ext. auxiliary voltage UAUX; dual LED green/red green: voltage OK red: reverse voltage
LED IN: switching state (input); 2 LED yellow
LED FUSE: Motor power supply; 2 green LEDs
LED DIR: Motor rotation direction; yellow LED
LED MOT: Motor active; 2 yellow LEDs
Auxiliary voltage (output): 18 ... 30 VDC PELV
Rated operating voltage: 26.5 ... 31.6 V from AS-Interface
Rated operating current: ≤ 35 mA
Number/Type: 2 Inputs for 3-wire sensors (PNP), DC
Supply: from external auxiliary voltage UAUX
Current loading capacity: 500 mA , overload and short-circuit protected
Input current: ≤ 8 mA (limited internally)
Switching point: according to DIN EN 61131-2 0 (undamped) ≤ 0.5 mA 1 (damped) ≥ 2.0 mA
Signal delay: < 1 ms (input/AS-Interface)
Input filter: 2 ms
Number/Type: 2 outputs for DC roller motors (MOT1, MOT2)
Supply: from external auxiliary voltage UAUX
Current: 3.5 A continuous current , 5 A (<2 s) , max. 7.5 A (<0,3 s) per motor
Overload protection: fuse , I2t = 53.7 A2s
Velocity signal: 1.4 … 13 V at no-load Ri = 5.6 kΩ, RLOAD ≥ 35 kΩ Control via parameter P2:0
Rotation direction signal: Off / ≥ (UAUX - 1.0 V) at no-load Ri = 5.6 kΩ, RLOAD ≥ 5 kΩ AS-Interface data bit D2 = 0: UD = Off
Motor fault: Digital input NPN, U0 = 3.3 V, Ri = 52 kΩ 0 (no error) ≥ 40 µA 1 (error) ≤ 30 µA
Electromagnetic compatibility: Directive 2014/30/EU: EN 62026-2:2013
Degree of protection: EN 60529:2000
Fieldbus standard: EN 62026-2:2013
Input: EN 61131-2:2007
Emitted interference: EN 61000-6-4:2007
AS-Interface: EN 62026-2:2013
Noise immunity: EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013
Profile: S-7.A.E
IO code: 7
ID code: A
ID1 code: 6
ID2 code: E
Data bits (function via AS-Interface): input output
Electromagnetic compatibility: D0: MOT1 fault MOT1 operation
Electromagnetic compatibility: D1: MOT2 fault MOT2 operation
Electromagnetic compatibility: D2: IN1 MOT1/MOT2 rotation direction
Electromagnetic compatibility: D3: IN2 -
Ambient temperature: -25 ... 60 °C (-13 ... 140 °F)
Storage temperature: -25 ... 85 °C (-13 ... 185 °F)
Degree of protection: IP54 according to EN 60529
Connection: AS-Interface, AUX: Insulation piercing technology Yellow flat cable/black flat cable Inputs/outputs: M8 round plug connector in accordance with EN 61076-2-104 Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded) Matching connector: LM004-Gx1-A or similar Outputs: NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded). Matching connector: NM005-Sx1-B or similar
Mass: 220 g
Mounting: 2 clips with ∅ 8 mm drill hole
Cable length: 1 m
Note: The flat cable routing is designed for 100 actuation cycles

Parametry logistyczne

ECCN:
Kraj pochodzenia: ID
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m