263759
PMI14V-F112-2EP-IO-V31
Inductive positioning system
Parameterization and diagnosis via IO-Link, 2 configurable switching frames, Measuring range 0 ... 14 mm, Housing material: diecast zinc, not laquered or coated, Connection type: M8 x 1 connector, 4-pin, Type of voltage: DC, Degree of protection: IP67fa
| Installation: | flush |
| Object distance: | max. 2.5 mm |
| Measurement range: | 0 ... 14 mm |
| Operating voltage: | 10 ... 30 V |
| Reverse polarity protection: | reverse polarity protected |
| Linearity error: | ± 0.3 mm |
| Repeat accuracy: | ± 0.05 mm |
| Resolution: | 33 µm |
| Temperature drift: | ± 0.5 mm |
| No-load supply current: | ≤ 20 mA |
| Operating voltage indicator: | LED green |
| MTTFd: | 490 a |
| Mission Time (TM): | 20 a |
| Diagnostic Coverage (DC): | 0 % |
| Interface type: | IO-Link |
| Mode: | COM 2 (38.4 kBaud) |
| Value range: | 0000h ... 7000h |
| Output type: | 2 Push-pull (4 in 1) outputs , short-circuit protected , reverse polarity protected , overvoltage protected , programmable |
| Operating current: | ≤ 100 mA / output |
| Switching hysteresis: | 3-step, adjustable 0.2 m ... 0.8 mm |
| Voltage drop: | ≤ 3 V |
| Short-circuit protection: | pulsing |
| Standard conformity: Standards: | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 IEC 61131-9:2013 |
| UL approval: | cULus Listed, Class 2 Power Source, Type 1 enclosure |
| CCC approval: | CCC approval / marking not required for products rated ≤36 V |
| Ambient temperature: | -25 ... 70 °C (-13 ... 158 °F) |
| Connection type: | M8 x 1 connector, 4-pin |
| Housing material: | diecast zinc, not laquered or coated |
| Degree of protection: | IP67 |
| Material: Target: | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) |
| Note: | The data relating to accuracy only apply to a distance to the object to be detected of 1 ... 2.5 mm. |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 0,00 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |