Pepperl+Fuchs 261493

VAS-2A8L-KE4-8SE

AS-Interface Sicherheitsmonitor VAS-2A8L-KE4-8SE

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

The AS-Interface safety monitor compact VAS-2A8L-KE4-8SE- is a control cabinet module with up to 8/4 local safe inputs and up to 8 independent outputs. The safe inputs can optionally be configured as standard inputs and signalling outputs. Two of the safe inputs are also suitable as inputs for OSSDs, the others only for potentialfree contacts. Each safe input can also be configured as two standard inputs. 8 independent AS-Interface release circuits support multiple safe AS-Interface outputs on a single address. In addition, the test pulse outputs can be switched as diagnostic outputs (not control- safe). The safe circuit for the connected consumers is created using two safety relays. The housing, which is only 22.5 mm wide, requires little space in the switch cabinet. The module is mounted by clicking it onto the 35 mm mouting rail, compliant with EN 50022. The AS-Interface and external power supply are each connected by means of a 2-station terminal block. Connection of the inputs and outputs is by means of multiple 4-station terminal blocks. This permits the simple removal of the supply during commissioning or servicing. The supply to the connected slaves is fed either internally via the module from the AS-interface or via an external supply. The current status of the inputs and outputs is indicated via yellow LEDs. Communication faults are indicated via red LEDs. The display of the operating voltage and the address 0 is provided by a green LED. A Micro-USB interface is used for configuration with the AS-i-Control Tools via ASIMON. The configuration can be transferred to a replacement device using a chip card.

Parametry techniczne

AS-Interface specification: V3.0
UL File Number: E223772
Safety Integrity Level (SIL): SIL 3
Performance level (PL): PL e
Mission Time (TM): 20 a
PFHd: 5.08 E-9
LED SM: Status of safety monitor, multicolored LED green: Safety monitor OK
LED S1 ... S8: Status of inputs S1 ... S8, yellow LED yellow: Contact open
LED O1, O2: Status of outlputs, multicolored LED yellow: Output on
Auxiliary voltage (input): 20 ... 30 VDC PELV
Insulation voltage: 500 V AS-Interface/UAUX:
Rated operating voltage: 18,0 ... 31.6 V from AS-Interface
Rated operating current: ≤ 200 mA from AS-Interface; ≤ 4 A from AUX
Interface type: Chip card slot
Interface type: Micro USB Programming interface
Number/Type: 8 / 4 safe inputs cat. 4 or 8 standard inputs
Supply: 24 V UAUX
Current loading capacity: 10 mA per signal output 1.4 A OSSD supply output
Input current: Static switching current 4 mA at 24 V, dynamic 30 mA at 24 V (T=100 μs)
Number/Type: Output circuits 1 and 2 max. contact rating: 700 m ADC-13 at 24  V
Supply: 24 V UAUX
Electromagnetic compatibility: Directive 2014/30/EU: EN 62026-2:2013 EN 61000-6-2:2005/AC:2005 EN 61000-6-4:2007/A1:2011
Machinery Directive: Directive 2006/42/EC: EN 13849-1:2008/AC:2009 EN 62061:2005
Electromagnetic compatibility: EN 50295:1999 EN 61000-6-2:2005/AC:2005 EN 61000-6-4:2007/A1:2011
Degree of protection: EN 60529:2000
Electrical safety: IEC 61508:2010 and EN 62061:2005 (up to SIL3) EN 13849-1:2008/AC:2009 EN 61326-3-1:2008
AS-Interface: EN 62026-2:2013
Profile: S-0.B.E
IO code: 0
ID code: B
ID1 code: F
Ambient temperature: 0 ... 55 °C (32 ... 131 °F)
Storage temperature: -25 ... 85 °C (-13 ... 185 °F)
Degree of protection: IP20
Connection: removable terminals rated connection capacity: rigid/flexible (with and without wire-end ferrules): 0.25 mm2 ... 2.5 mm2 for multiple-wire connection with two wires of equal cross-section: flexible with twin wire-end ferrules: 0.5 mm2 ... 1.5 mm2
Material: Housing: PA 66-FR
Mounting: DIN mounting rail

Parametry logistyczne

ECCN:
Kraj pochodzenia: TR
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m