256918
M-LB-EX-5113
Protection Module
The protection module limits induced transients of different causes, e. g. lightning or switching operations. The limitation is achieved by diverting the current to earth and limiting the signal circuit voltage during the duration of the overvoltage pulse. Surge protection for 1 signal line, Nominal voltage 1 V DC, Protection module for grounded signal lines, Max. surge current (8/20 µs) 10 kA, Uninterruptable operation (auto reset), Mounting on base module, pluggable, Up to SIL 3 acc. to IEC 61508pa. The device is used in applications where more than 2 signal lines have to be protected, e. g. in applications with 3-wire resistance thermometers or 4-/6-wire measuring bridges. The device is HART transparent. The device is inserted onto the base module and forms the surge protection barrier together with the base module. The device can be replaced without tools by a locking lever.
| Number of protected signal lines: | 1 |
| Topology: | grounded |
| Safety Integrity Level (SIL): | SIL 3 |
| Connection: | protected area: terminal 4 unprotected area: terminals 1, 3 |
| Rated current: | 500 mA , restrictions see derating characteristics |
| Leakage current: | < 5 µA x (number of used modules - 1) at 1 V and 25 °C (77 °F) . line-line |
| Nominal voltage: | 1 V DC |
| Maximum continuous operating voltage: | 6 V DC |
| Series resistance: | ≤ 0.6 Ω per line |
| Impulse rating: | 1 kV/0.5 kA (category C1) 10 kV/5 kA (category C2) 1 kA (category D1) |
| Impulse discharge current (10/350 µs): | 1 kA per line (2x) |
| Nominal discharge current (8/20 µs): | 5 kA per line (10x) |
| Rated surge current (8/20 µs): | 10 kA per line (1x) |
| Total discharge current (8/20 µs): | 10 kA (1x) |
| Voltage protection level: | max. 22 V line-line for nominal discharge current In max. 31 V line-earth for nominal discharge current In |
| Impulse reset time: | < 500 ms |
| Insertion loss: | ≤ 0.05 dB, at 0 ... 4 kHz, in 600 Ω-System ≤ 3 dB, at 0 ... 350 kHz, in 100 Ω-System |
| Degree of protection: | IEC 60529:2013 |
| Functional safety: | IEC/EN 61508:2010 |
| Surge protective devices for low voltage: | EN 61643-21:2001+A1:2009+A2:2013 IEC 61643-21:2001+A1:2008+A2:2012 |
| Ambient temperature: | -40 ... 80 °C (-40 ... 176 °F) Observe the temperature range limited by derating, see section derating. |
| Storage temperature: | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity: | max. 95 % , without condensation |
| Degree of protection: | IP20 |
| Mass: | approx. 20 g |
| Dimensions: | 6.2 x 77 x 79 mm |
| Mounting: | pluggable in base module for mounting on 35 mm DIN mounting rail |
| EU-type examination certificate: | BVS 17 ATEX E 069 X |
| : Marking: | II 2(1)G Ex ia [ia Ga] IIC T6...T4 Gb II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I |
| : Temperature class: | T6 for ambient temperature ≤ 60 °C T5 for ambient temperature ≤ 70 °C T4 for ambient temperature ≤ 80 °C |
| : Voltage: | 6 V |
| : Current: | 500 mA , restrictions see derating characteristics |
| : Internal capacitance: | negligible |
| : Internal inductance: | 18 µH |
| Directive conformity: Directive 2014/34/EU: | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 |
| IECEx approval: IECEx certificate: | IECEx BVS 17.0061X |
| IECEx approval: IECEx marking: | Ex ia [ia Ga] IIC T6...T4 Gb [Ex ia Da] IIIC [Ex ia Ma] I |
| Supplementary information: | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |
| Designation: | system components: - base module with screw terminals M-LB-Ex-5000 - base module with spring terminals M-LB-Ex-5000.SP - place holder module M-LB-Ex-5900 - separation wall M-UPR-I |
| ECCN: | |
| Kraj pochodzenia: | Singapur |
| EAN: | 4050143064465 |
| Waga: | 0,04 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |