4 channels, Inputs Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Converter for 2-, 3- and 4-wire RTDs (Pt100 .. Pt1000), slide wire sensors etc.pa. The RTD converter accepts 2-, 3-, 4-wire RTD signals (Pt100 .. Pt1000) and slide-wire sensors from the field. Ni100 through Ni1000 can also be connected. Open and short-circuit line faults are detected. The intrinsically safe inputs are galvanically isolated from the bus and the power supply.

Parametry techniczne

Occupied slots: 2
Connection: backplane bus
Rated voltage: 12 V DC , only in connection with the power supplies LB9***
Power dissipation: 0.35 W
Power consumption: 0.35 W
Connection: backplane bus
Interface: manufacturer-specific bus to standard com unit
Number of channels: 4
Suitable field devices: Field device: resistance thermometer
Suitable field devices: Field device [2]: slide-wire sensors
Suitable field devices: Field device [3]: potentiometer
Field device interface: Connection: 2-wire sensor
Field device interface: Connection [2]: 3-wire sensor
Field device interface: Connection [3]: 4-wire sensor
Connection: channel I: resistance/potentiometer input 1 ... 4 channel II: resistance/potentiometer input 5 ... 8 channel III: resistance/potentiometer input 9 ... 12 channel IV: resistance/potentiometer input 13 ... 16
Measurement range: Pt100 (18-390 Ω) (500 Ω incl. line resistance) Pt200 (37-780 Ω) Pt500 (92-1952 Ω) Pt1000 (185-3905 Ω) Ni100 (69-270 Ω) Ni500 (345-1350 Ω) Ni1000 (690-2700 Ω)
Slide-wire sensor: 0 ... 10 kΩ
Measuring current: 200 µA
Smallest span: 50 Ω for 0.1 % accuracy
Linearity error: 0.1 %
Conversion time: max. 500 ms (4 channels) max. 1 s (for 4x 3-wire Pt100)
Busy after download: 5 ... 15 s
Lead resistance: max. 50 Ω per strand
Line fault detection: can be switched on/off for each channel via configuration tool
Field device interface: Short-circuit: < 10 Ω
Field device interface: Open-circuit: > 1 kΩ
Deviation: Influence of ambient temperature: max. 0,1 %/10 K
LED indication: Power LED (P) green: supply Status LED (I) red: line fault (collective alarm) , red flashing: communication error
Coding: optional mechanical coding via front socket
Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1
Electromagnetic compatibility: NE 21
Degree of protection: IEC 60529
Environmental test: EN 60068-2-14
Shock resistance: EN 60068-2-27
Vibration resistance: EN 60068-2-6
Damaging gas: EN 60068-2-42
Relative humidity: EN 60068-2-56
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
Storage temperature: -25 ... 85 °C (-13 ... 185 °F)
Relative humidity: 95 % non-condensing
Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Degree of protection: IP20 when mounted on backplane
Connection: removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Mass: approx. 150 g
Dimensions: 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch)
EU-type examination certificate: PTB 03 ATEX 2042 X
Electromagnetic compatibility: Marking: II (1) G [Ex ia] IIC II (1) D [Ex ia] IIIC
Input: Voltage: 7.14 V
Input: Current: 70 mA
Input: Power: 123 mW (linear characteristic)
Certificate: PF 08 CERT 1234 X
Input: Marking: II 3 G Ex nA IIC T4 Gc
Galvanic isolation: Input/power supply, internal bus: safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EU: EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010 EN 61241-11:2006
ATEX approval: PTB 03 ATEX 2042 X
UL approval: E106378
Directive conformity: Control drawing: 116-0322
IECEx approval: BVS 09.0037X
Directive conformity: Approved for: Ex nA [ia Ga] IIC T4 Gc [Ex ia Da] IIIC
Marine approval: Lloyd Register: 15/20021
Marine approval: DNV GL Marine: TAA0000034
Marine approval: Bureau Veritas Marine: 22449/B0 BV
System information: The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Parametry logistyczne

ECCN:
Kraj pochodzenia: SG
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m