244407
LB1009A
Digital Input
8-channel, Inputs Ex ic, Installation in Zone 2 or safe area, Dry contact or NAMUR inputspa. The device accepts digital input signals of NAMUR sensors or mechanical contacts from the field. Furthermore it can accept active signals with 24 V or 5 V DC in the safe area. Open and short circuit line faults are detected. This does not apply for active signals. The inputs are galvanically isolated from the bus and the power supply.
| Occupied slots: | 1 |
| Connection: | backplane bus |
| Rated voltage: | 12 V DC , only in connection with the power supplies LB9*** |
| Power dissipation: | 1.55 W |
| Power consumption: | 1.55 W |
| Connection: | backplane bus |
| Interface: | manufacturer-specific bus to standard com unit |
| Number of channels: | 8 |
| Sensor interface: Connection: | NAMUR sensor |
| Sensor interface: Connection [2]: | volt-free contact |
| Sensor interface: Connection [3]: | Usage without connection to areas where there is a risk of explosion: active signals, mechanical contacts, NAMUR proximity switches, 2-wire sensors If the device has been operated in general electrical systems that are not connected to areas where there is a risk of explosion, the device cannot then be used in electrical systems that are connected to areas where there is a risk of explosion. Usage with connection to areas where there is a risk of explosion: mechanical contacts, NAMUR proximity switches |
| Connection: | Terminals 1+, 2-, 3+, 4-, 5+, 6-, 7+, 8-, 9+, 10-, 11+, 12-, 13+,14-, 15+, 16- |
| Rated values: | acc. to EN 60947-5-6 (NAMUR) |
| Switching point/switching hysteresis: | 1.2 ... 2.1 mA / ± 0.2 mA |
| Voltage: | 8.2 V |
| Internal resistor: | 1 kΩ |
| Line fault detection: | can be switched on/off for each channel via configuration tool , active signals (24 V, 5 V) without line fault detection |
| Sensor interface: Connection: | mechanical switch with additional resistors (see connection diagram) proximity switches without additional wiring |
| Sensor interface: Short-circuit: | < 360 Ω |
| Sensor interface: Open-circuit: | < 0.35 mA |
| Digital signals (active): | Use in safe area: configurable 24 V 5 V |
| Sensor interface: Switching point: ON: | > 8 V > 2.7 V |
| Sensor interface: Switching point: OFF: | < 3 V < 2.3 V |
| Minimum pulse duration: | 15 ms |
| LED indication: | Power LED (P) green: supply Diagnostic LED (I) red: module fault , red flashing: communication error , white: fixed parameter set (parameters from com unit are ignored) , white flashing: requests parameters from com unit Status LED (1-8) red: line fault (lead breakage or short circuit) , yellow: signal (per channel) |
| Coding: | optional mechanical coding via front socket |
| Electromagnetic compatibility: Directive 2014/30/EU: | EN 61326-1 |
| Electromagnetic compatibility: | NE 21 |
| Degree of protection: | IEC 60529 |
| Environmental test: | EN 60068-2-14 |
| Shock resistance: | EN 60068-2-27 |
| Vibration resistance: | EN 60068-2-6 |
| Damaging gas: | EN 60068-2-42 |
| Relative humidity: | EN 60068-2-56 |
| Ambient temperature: | -20 ... 60 °C (-4 ... 140 °F) , 70 °C (non-Ex) |
| Storage temperature: | -25 ... 85 °C (-13 ... 185 °F) |
| Relative humidity: | 95 % non-condensing |
| Shock resistance: | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 |
| Vibration resistance: | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance |
| Damaging gas: | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
| Degree of protection: | IP20 when mounted on backplane |
| Connection: | removable front connector with spring terminal (0.14 ... 0.5 mm2) |
| Mass: | approx. 90 g |
| Dimensions: | 16 x 100 x 102 mm (0.63 x 3.9 x 4 inch) |
| Input: Voltage: | 10 V |
| Input: Current: | 12 mA |
| Input: Power: | 30 mW (linear characteristic) |
| Certificate: | EXA 13 ATEX 0037X |
| Input: Marking: | II 3 G Ex nA [ic] IIC T4 Gc |
| Galvanic isolation: Input/power supply, internal bus: | safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V |
| Directive conformity: Directive 2014/34/EU: | EN 60079-0:2011 EN 60079-11:2011 EN 60079-15:2010 |
| ATEX approval: | EXA 13 ATEX 0037X |
| IECEx approval: | EXA 13.0003X |
| Directive conformity: Approved for: | Ex nA [ic] IIC T4 Gc |
| Marine approval: Lloyd Register: | 15/20021 |
| Marine approval: Bureau Veritas Marine: | 22449/B0 BV |
| System information: | The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2 or Zone 22) the module must be installed in an appropriate enclosure. |
| Supplementary information: | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |