239818
KT-MB-GT2AD.FF
Advanced Diagnostic Gateway with Ethernet and FF-H1 Interface
The FieldConnex. Diagnostic Gateway is the interface between stationary Advanced Diagnostic Modules (ADM) and the control system. It offers access to all ADM data in two ways: via Ethernet and the Diagnostic Manager software or via FOUNDATION Fieldbus H1 and DTM/EDD or both. System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, System integration kit for Advanced Diagnostics, PCS integration via Diagnostic Manager or device DTM, Simple automatic setup of Advanced Diagnostics, Common alarm handling, For FOUNDATION Fieldbus and PROFIBUS PApa. The gateway configures itself and automatically detects the ADMs. The Diagnostic Manager automatically finds gateways on the same subnet. The setup of the diagnostic bus and all connected modules is automatic. This significantly simplifies engineering of FieldConnex. Advanced Diagnostics.
| Design / Mounting: | Motherboard based |
| Rated voltage: | 19.2 ... 35 V DC SELV/PELV |
| Rated current: | 120 ... 70 mA |
| Power dissipation: | max. 2.5 W |
| Fieldbus type: | FOUNDATION Fieldbus |
| Physical layer profile: | profile type 114 |
| ITK version: | 6 |
| Implementation: | resource block 1x RS function block 4x MDI, 1x MDO, 1x MAI, 1x DI transducer block 16x ADM TB, 1x IO TB |
| Firmware update: | Ethernet |
| Polarity: | polarity-sensitive |
| Rated voltage: | 9 ... 35 V SELV/PELV |
| Rated current: | 0 mA |
| Port: | 100 BASE-TX |
| Protocol: | TCP/IP and UDP/IP |
| Services: | ICMP , DHCP , AutoIP , HTTP |
| Connection type: | RJ-45 socket, 8-pin |
| Transfer rate: | 100 MBit/s |
| Number of Diagnostic Bus Channels: | 2 |
| Number of Diagnostic Modules/Channel: | 31 Using Ethernet Interface , 8 Using Fieldbus Interface |
| Termination: | integrated |
| Cable length/Channel: | 30 m |
| LED ERR: | red: Hardware fault |
| LED PWR: | green: Power on |
| LINK/ACT: | yellow |
| CH1, CH2: | yellow: diagnostic bus activity |
| Output I: | alarm output diagnostic bus channel 1 , volt-free contact , NC contact |
| : Voltage: | 50 V DC |
| : Current: | max. 1 A |
| Output II: | alarm output diagnostic bus channel 2 , volt-free contact , NC contact |
| : Voltage: | 50 V DC |
| : Current: | max. 1 A |
| Output III: | common alarm , volt-free contact , NC contact |
| : Voltage: | 50 V DC |
| : Current: | max. 1 A |
| All circuits/FE: | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Output I, II/other circuits: | functional insulation acc. to IEC 62103, rated insulation voltage 250 Veff |
| Ethernet/Supply: | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Ethernet/other circuits: | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Fieldbus/other circuits: | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Diagnostic Bus/other circuits: | functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff |
| Electromagnetic compatibility: Directive 2014/30/EU: | EN 61326-1:2013 |
| Galvanic isolation: | IEC 62103 |
| Electromagnetic compatibility: | NE 21 |
| Degree of protection: | IEC 60529 |
| Fieldbus standard: | IEC 61158-2 |
| Climatic conditions: | DIN IEC 721 |
| Shock resistance: | EN 60068-2-27 |
| Vibration resistance: | EN 60068-2-6 |
| Ethernet: | IEEE 802.3 |
| Ambient temperature: | -40 ... 60 °C (-40 ... 140 °F) hazardous area -40 ... 70 °C (-40 ... 158 °F) safe area horizontal DIN rail mounting |
| Storage temperature: | -40 ... 85 °C (-40 ... 185 °F) |
| Relative humidity: | < 95 % non-condensing |
| Shock resistance: | 15 g 11 ms |
| Vibration resistance: | 1 g , 10 ... 150 Hz |
| Pollution degree: | max. 2, according to IEC 60664 |
| Corrosion resistance: | acc. to ISA-S71.04-1985, severity level G3 |
| Housing material: | Polycarbonate |
| Housing width: | see dimensions |
| Housing height: | see dimensions |
| Housing depth: | see dimensions |
| Degree of protection: | IP20 |
| Mass: | 470 g |
| Mounting: | DIN rail mounting |
| Certificate: | TÜV 14 ATEX 115980 X |
| Electromagnetic compatibility: Marking: | II 3 G Ex nA IIC T4 Gc |
| Directive conformity: Directive 2014/34/EU: | EN 60079-0:2012 , EN 60079-11:2012 , EN 60079-15:2010 |
| IECEx approval: | IECEx TUN 14.0003X |
| Directive conformity: Approved for: | Ex nA IIC T4 Gc |
| Supplementary information: | Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
| ECCN: | |
| Kraj pochodzenia: | SG |
| EAN: | |
| Waga: | 0,00 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |