Pepperl+Fuchs 238426

UCC500-30GH70-IE2R2-K-V15

Ultrasonic sensor

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Ultrasonic diffuse sensor with separate transducer, Analog output 4 .. 20 mA, 1 switch output, Temperature compensation, Series: -30GM, Construction type: Cylindrical, Housing: Stainless steel 1.4571 / AISI 316Ti plastic PBT, Connection type: Connector plug M12 x 1 , 5-pinfa

Parametry techniczne

Sensing range: 45 ... 500 mm
Adjustment range: 50 ... 500 mm
Dead band: 0 ... 45 mm
Standard target plate: 100 mm x 100 mm
Transducer frequency: approx. 300 kHz
Response delay: ≤ 60 ms
Temperature drift: ≤ ± 1.5 % of full-scale value
Time delay before availability: ≤ 85 ms
Permissible cable length: max. 300 m
LED yellow: switching state switch output
LED green/yellow: yellow: object in evaluation range green: Teach-In
Potentiometer: switch output adjustable
Rated operating voltage: 24 V DC
Operating voltage: 20 ... 30 V DC (including ripple)
Ripple: ≤ 10 %
No-load supply current: ≤ 50 mA
Interface type: Infrared
Mode: point-to-point connection
Input/output type: 1 synchronization connection, bidirectional ( Factory setting: synchronized mode ) / Teach-In input
: 0 Level: ≤ 3 V
: 1 Level: ≥ 15 V
: Input impedance: typ. 900 Ω
: Number of sensors: max. 10
Output type: 1 switch output PNP, NO ( NC contact programmable )
Default setting: 50 ... 500 mm ( adjustable via potentiometer )
Repeat accuracy: ± 0.5 mm
Operating current: 300 mA , short-circuit/overload protected
Switching frequency: ≤ 5 Hz
Switching hysteresis: 5 mm ( programmable )
Voltage drop: ≤ 3 V
Off-state current: ≤ 10 µA
Output type: 1 current output 4 ... 20 mA , ascending/descending programmable
Default setting: rising ramp ; evaluation limit A1: 50 mm ; evaluation limit A2: 500 mm
Load resistor: ≤ 500 Ω
Standard conformity: Standards: EN 60947-5-2:2007+A1:2012 IEC 60947-5-2:2007 + A1:2012 EN 60947-5-7:2003 IEC 60947-5-7:2003
UL approval: cULus Listed, General Purpose
CSA approval: cCSAus Listed, General Purpose
CCC approval: CCC approval / marking not required for products rated ≤36 V
Ambient temperature: -25 ... 70 °C (-13 ... 158 °F)
Storage temperature: -40 ... 85 °C (-40 ... 185 °F)
Shock resistance: 30 g , 11 ms period
Vibration resistance: 10 ... 55 Hz , Amplitude ± 1 mm
Connection type: Connector plug M12 x 1 , 5-pin
Degree of protection: IP65
Material: Housing: Stainless steel 1.4571 / AISI 316Ti plastic PBT
Material: Cable: PVC
Material: Transducer: FEP coated; epoxy resin/hollow glass sphere mixture; polyurethane foam
Installation position: any position
Mass: 190 g
Construction type: Cylindrical
Cable length: 165 cm

Parametry logistyczne

ECCN:
Kraj pochodzenia: SG
EAN:
Waga: 0,28 kg
Długość: 0,00 m
Szerokość: 0,00 m