Pepperl+Fuchs 231200

KFD2-UFT-Ex2.D

Frequency Converter with Direction and Synchronization Monitor

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

2-channel isolated barrier, 24 V DC supply (Power Rail), Dry contact or NAMUR inputs, Input frequency 1 mHz .. 1 kHz, Current output 0/4 mA ... 20 mA, Relay contact and transistor output, Start-up override, Configurable by PACTware or keypad, Line fault detection (LFD)pa. This isolated barrier is used for intrinsic safety applications. It analyzes 2 digital signals (NAMUR sensor/mechanical contact) from a hazardous area and functions as a rotation direction indicator, slip monitor, frequency monitor or synchronization monitor. Each proximity sensor or switch controls a passive transistor output. The 2 relay outputs indicate if the input signal is above or below the trip value or the rotational direction. The analog output can be programmed to be proportional to the input frequency or slip differential. The unit is easily programmed by the use of a keypad located on the front of the unit or with the PACTware™ configuration software. Line fault detection of the field current is indicated by a red LED. For additional information, refer to the manual and www.pepperl-fuchs.com.

Parametry techniczne

Signal type: Digital Input
Connection: terminals 23+, 24- or power feed module/Power Rail
Rated voltage: 20 ... 30 V DC
Rated current: approx. 130 mA
Power dissipation: 2.2 W
Power consumption: 2.5 W
Programming interface: programming socket
Connection side: field side
Connection: input I: terminals 1+, 3- input II: terminals 4+, 6- input III: terminals 13+, 14- (control input 1) input IV: terminals 15+, 14- (control input 2)
Input I, II: 2-wire sensor, sensor acc. to EN 60947-5-6 (NAMUR) or mechanical contact
: Open circuit voltage/short-circuit current: 8.2 V / 10 mA
: Pulse duration: min. 250 µs , overlap on direction of rotation signal: ≥ 125 µs
: Input frequency: rotation direction monitoring 0.001 ... 1000 Hz slip monitoring 10 ... 1000 Hz
: Line fault detection: breakage I ≤ 0.15 mA; short-circuit I > 6.5 mA
Input III, IV: Active/Passive: I > 4 mA (for min. 100 ms) / I < 1.5 mA
Input III, IV: Open circuit voltage/short-circuit current: 18 V / 5 mA
Connection side: control side
Connection: output I: terminals 10, 11, 12 output II: terminals 16, 17, 18 output III: terminals 19+, 20- output IV: terminals 21+, 20- output V: terminals 7-, 8+
Output I, II: signal , relay
Input III, IV: Contact loading: 250 V AC / 2 A / cos φ ≥ 0.7 ; 40 V DC / 2 A
Input III, IV: Mechanical life: 5 x 107 switching cycles
Input III, IV: Energized/De-energized delay: approx. 20 ms / approx. 20 ms
Output III and IV: signal , electronic output, passive
Input III, IV: Contact loading: 40 V DC
Input III, IV: Signal level: 1-signal: (external voltage) - 2.5 V max. for 10 mA or 3 V max. for 100 mA (100 mA, short-circuit proof) -2.5 V (50 mA, short-circuit/overload proof) 0-signal: switched off (off-state current ≤ 10 µA)
Output V: analog
Input III, IV: Current range: 0 ... 20 mA or 4 ... 20 mA
Input III, IV: Open loop voltage: max. 24 V DC
Input III, IV: Load: max. 650 Ω
Input III, IV: Fault signal: downscale I ≤ 3.6 mA, upscale I ≥ 21.5 mA (acc. NAMUR NE43)
Collective error message: Power Rail
Input I and II: Measurement range: 0.001 ... 1000 Hz
Input I and II: Resolution: slip monitoring: 1% frequency measurement: 0,1% of measured value; but >0.001Hz
Input I and II: Accuracy: slip monitoring: 1% frequency measurement: 0.5% of measured value; but >0.001Hz
Input I and II: Measuring time: frequency measurement: < 100 ms
Input I and II: Influence of ambient temperature: 0.003 %/K (30 ppm)
Output I, II: Response delay: ≤ 200 ms
Output V: Resolution: < 10 µA
Output V: Accuracy: < 30 µA
Output V: Influence of ambient temperature: 0.005 %/K (50 ppm)
Input I, II/other circuits: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Input III, IV/power supply and collective error: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Output I, II/other circuits: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Mutual output I, II, III: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Mutual output I, II, IV: reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff
Output III, IV/power supply and collective error: basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output III, IV/input III, IV: basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output III, IV/V: basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Output V/power supply and collective error: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Interface/power supply and collective error: functional insulation acc. to IEC 62103, rated insulation voltage 50 Veff
Interface/output III, IV: basic insulation according to IEC/EN 61010-1, rated insulation voltage 50 Veff
Display elements: LEDs , display
Control elements: Control panel
Configuration: via operating buttons via PACTware
Labeling: space for labeling at the front
Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1:2013 (industrial locations)
Low voltage: Directive 2014/35/EU: EN 61010-1:2010
Electromagnetic compatibility: NE 21:2006
Degree of protection: IEC 60529:2001
Input: EN 60947-5-6:2000
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
Degree of protection: IP20
Connection: screw terminals
Mass: 300 g
Dimensions: 40 x 119 x 115 mm (1.6 x 4.7 x 4.5 inch) , housing type C3
Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001
EU-type examination certificate: TÜV 99 ATEX 1471
Low voltage: Marking: II (1)G [Ex ia Ga] IIC II (1)D [Ex ia Da] IIIC I (M1) [Ex ia Ma] I
Supply: Maximum safe voltage: 40 V DC (Attention! Um is no rated voltage.)
Input I and II: terminals 1+, 3-; 4+, 6-: Ex ia
Supply: Voltage Uo: 10.1 V
Supply: Current Io: 13.5 mA
Supply: Power Po: 34 mW (linear characteristic)
Input III and IV: terminals 13+, 14-; 15+, 14- non-intrinsically safe
Supply: Maximum safe voltage Um: 40 V (Attention! Um is no rated voltage.)
Output I, II: terminals 10, 11, 12; 16, 17, 18 non-intrinsically safe
Supply: Maximum safe voltage: 253 V (Attention! The rated voltage can be lower.)
Supply: Contact loading: 253 V AC/2 A/cos φ > 0.7; 40 V DC/2 A resistive load (TÜV 99 ATEX 1471)
Output III and IV: terminals 19, 20, 21 non-intrinsically safe
Supply: Maximum safe voltage Um: 40 V DC (Attention! Um is no rated voltage.)
Output V: terminals 8+, 7- non-intrinsically safe
Supply: Maximum safe voltage Um: 40 V DC (Attention! Um is no rated voltage.)
Interface: RS 232
Supply: Maximum safe voltage: 40 V (Attention! Um is no rated voltage.)
Certificate: TÜV 02 ATEX 1885 X
Supply: Marking: II 3G Ex nA nC IIC T4 Gc
Output I, II: Contact loading: 50 V AC/2 A/cos φ > 0.7; 40 V DC/1 A resistive load
Galvanic isolation: Input I, II/other circuits: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
FM approval: Control drawing: 16-538FM-12
UL approval: E223772
IECEx approval: IECEx TUN 04.0007
FM approval: Approved for: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.