Pepperl+Fuchs 225696

KCD2-UT2-Ex1

Universal Temperature Converter

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

1-channel isolated barrier, 24 V DC supply (Power Rail), Thermocouple, RTD, potentiometer or voltage input, Current output 0/4 mA ... 20 mA, Sink or source mode, Configurable by PACTware, Line fault (LFD) and sensor burnout detection, Up to SIL 2 acc. to IEC 61508/IEC 61511pa. This isolated barrier is used for intrinsic safety applications. The device converts RTD input signals or thermocouple input signals in the hazardous area to 0/4 mA ... 20mA signals in the safe area. The removable terminal block KC-CJC-** is available for thermocouples when internal cold junction compensation is desired. A fault is indicated by an LED and by user-configured fault indication outputs. If the device is operated via Power Rail, additionally a collective error message is available. The device is easily configured by the use of the PACTware configuration software. For additional information, refer to the manual and www.pepperl-fuchs.com.

Parametry techniczne

Signal type: Analog input
Safety Integrity Level (SIL): SIL 2
Connection: terminals 9+, 10- or power feed module/Power Rail
Rated voltage: 19 ... 30 V DC
Ripple: within the supply tolerance
Power dissipation/power consumption: ≤ 0.98 W / 0.98 W
Programming interface: programming socket
Connection side: field side
Connection: terminals 1, 2, 3, 4
RTD: type Pt10, Pt50, Pt100, Pt500, Pt1000 (EN 60751: 1995) type Pt10GOST, Pt50GOST, Pt100GOST, Pt500GOST, Pt1000GOST (6651-94) type Cu10, Cu50, Cu100 (P50353-92) type Ni100 (DIN 43760)
: Measuring current: approx. 200 µA with RTD
: Types of measuring: 2-, 3-, 4-wire connection
: Lead resistance: max. 50 Ω per line
: Measurement loop monitoring: sensor breakage, sensor short-circuit
Thermocouples: type B, E, J, K, N, R, S, T (IEC 584-1: 1995) type L (DIN 43710: 1985) type TXK, TXKH, TXA (P8.585-2001)
: Cold junction compensation: external and internal
: Measurement loop monitoring: sensor breakage
Potentiometer: 0 ... 20 kΩ (2-wire connection), 0.8 ... 20 kΩ (3-wire connection)
Voltage: selectable within the range -100 ... 100 mV
Input resistance: ≥ 1 MΩ (-100 ... 100 mV)
Connection side: control side
Connection: terminal 5: source (-), terminal 6: source (+), terminal 7: sink(-), terminal 8: sink (+)
Output: Analog current output
: Current range: 0 ... 20 mA or 4 ... 20 mA
: Fault signal: downscale 0 or 2 mA, upscale 21.5 mA (acc. NAMUR NE43)
: Source: load 0 ... 550 Ω open-circuit voltage ≤ 18 V
: Sink: Voltage across terminals 5 ... 30 V. If the current is supplied from a source > 16.5 V, series resistance of ≥ (V - 16.5)/0.0215 Ω is needed, where V is the source voltage. The maximum value of the resistance is (V - 5)/0.0215 Ω.
Deviation: After calibration: Pt100: ± (0.06 % of measurement value in K + 0.1 % of span + 0.1 K (4-wire connection)) thermocouple: ± (0.05 % of measurement value in °C + 0.1 % of span + 1.5 K (1.7 K for types R and S)) this includes ± 1.3 K error of the cold junction compensation mV: ± (50 µV + 0.1 % of span) potentiometer: ± (0.05 % of full scale + 0.1 % of span, (excludes errors due to lead resistance))
Deviation: Influence of ambient temperature: deviation of CJC included: Pt100: ± (0.0015 % of measurement value in K + 0.006 % of span)/K ΔTamb*) thermocouple: ± (0.02 K + 0.005 % of measurement value in °C + 0.006 % of span)/K ΔTamb*) mV: ± (0.01 % of measurement value + 0.006 % of span)/K ΔTamb*) potentiometer: ± 0.006 % of span/K ΔTamb*) *) ΔTamb = ambient temperature change referenced to 23 °C (296 K)
Deviation: Influence of supply voltage: < 0.01 % of span
Deviation: Influence of load: ≤ 0.001 % of output value per 100 Ω
Reaction time: worst case value (sensor breakage and/or sensor short circuit detection enabled) mV: 1 s, thermocouples with CJC: 1.1 s, thermocouples with fixed reference temperature: 1.1 s, 3- or 4-wire RTD: 920 ms, 2-wire RTD: 800 ms, Potentiometer: 2.05 s
Output/supply, programming input: functional insulation, rated insulation voltage 50 V AC There is no electrical isolation between the programming input and the supply. The programming cable provides galvanic isolation so that ground loops are avoided.
Display elements: LEDs
Configuration: via PACTware
Labeling: space for labeling at the front
Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1:2013 (industrial locations)
Electromagnetic compatibility: NE 21:2012 EN 61326-3-2:2008
Degree of protection: IEC 60529:2001
Protection against electrical shock: UL 61010-1:2004
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
Degree of protection: IP20
Connection: screw terminals
Mass: approx. 100 g
Dimensions: 12.5 x 114 x 124 mm (0.5 x 4.5 x 4.9 inch) , housing type A2
Mounting: on 35 mm DIN mounting rail acc. to EN 60715:2001
EU-type examination certificate: BASEEFA 13 ATEX 0102 X
Electromagnetic compatibility: Marking: II (1)G [Ex ia Ga] IIC , II (1)D [Ex ia Da] IIIC , I (M1) [Ex ia Ma] I
Electromagnetic compatibility: Input: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Inputs: terminals 1, 2, 3, 4
Electromagnetic compatibility: Voltage Uo: 9 V
Electromagnetic compatibility: Current Io: 13.1 mA
Electromagnetic compatibility: Power Po: 30 mW
Analog outputs, power supply, collective error: Maximum safe voltage: 250 V (Attention! This is not the rated voltage.)
Interface: Maximum safe voltage: 250 V (Attention! The rated voltage is lower.), RS 232
Certificate: BASEEFA 13 ATEX 0103 X
Interface: Marking: II 3G Ex nA II T4 Gc [device in zone 2]
Galvanic isolation: Input/Other circuits: safe electrical isolation acc. to IEC/EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EU: EN 60079-0:2012+A11:2013 , EN 60079-11:2012 , EN 60079-15:2010
UL approval: Control drawing: 116-0379 (cULus)
IECEx approval: IECEx BAS 13.0057X
UL approval: Approved for: [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I
Supplementary information: Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com.

Parametry logistyczne

ECCN:
Kraj pochodzenia: SG
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m