223349
IC-KP2-2HB18-2V1
Control interface unit
The RFID identification system IDENTControl Compact from Pepperl+Fuchs offers a vast number of benefits compared to other systems, thanks to its innovative design. The control interfaces IDENTControl and IDENTControl Compact make up the core of the system. IDENTControl Compact control interface with CC-Link V2 interfacefa. With its integrated interfaces to all commercially available fieldbus systems such as PROFIBUS, PROFINET, Ethernet, EtherCAT, CC-Link, serial connections (RS 232 or RS 485) and numerous connection options for read/write heads available for frequency ranges LF, HF and UHF, the IDENTControl Compact control interface can be easily and flexibly adapted to your requirements. LEDs on the front of the housing indicate bus communication, connected read/write heads and active read/write commands. Reliability of the application is further increased by using trigger sensors. The system is equally suited for use in control cabinets and field use in IP67. The interface to the higher-level fieldbus is integrated in the housing, and all connections are designed such that they are pluggable. This enables simple installation and quick, problem-free replacement in case of device failure. The consistent EMC design, with metal housing, grounding and shielded wires, offers a high degree of reliability.
| Number of read/write heads: | max. 2 alternatively 1 read/write head and 1 trigger sensor |
| UL File Number: | E87056 |
| MTTFd: | 170 a |
| Mission Time (TM): | 10 a |
| Diagnostic Coverage (DC): | 0 % |
| LEDs 1, 2: | Status indicator for read/write heads green: command at read/write head active yellow: approx. 1 second long, if command was successfully executed |
| LEDs CH1, CH2: | green: read head detected red: Configuration error |
| LED PWR/ERR: | green: power on red: Hardware fault |
| LED L RUN: | green: on, data communication active |
| LED L ERR: | red: on, invalid rotary switch setting or data transfer failure red: flashing, rotary switch setting changed since last switched on |
| Rotary switch: | Address setting 01 ... 64 (decimal) Station no.: 0 ... 6 (x10) Station no.: 0 ... 9 (x1) Baud rate setting: 0 ... 4 Extended cyclic setting: 0, 1, 2, 4, 8 |
| Rated operating voltage: | 20 ... 30 V DC , PELV |
| Ripple: | ≤ 10 % at 30 V DC |
| Current consumption: | ≤ 4 A incl. read/write heads |
| Power consumption: | 3.5 W Without read/write heads |
| Galvanic isolation: | basic insulation acc. to DIN EN 50178, rated insulation voltage of 50 Veff |
| Interface type: | CC-Link |
| Physical: | RS-485 |
| Protocol: | CC-Link |
| Transfer rate: | 156; 625 kBit/s 2,5;5;10 Mbit/s |
| Interface type: | Diagnostic Interface |
| Physical: | RS 232 |
| Protocol: | ASCII |
| Transfer rate: | 38.4 kBit/s |
| Electromagnetic compatibility: Directive 2014/30/EU: | EN 61000-6-2 EN 61000-6-4 |
| RoHS: Directive 2011/65/EU (RoHS): | EN 50581 |
| Degree of protection: | IEC 60529 |
| Ambient temperature: | -25 ... 70 °C (-13 ... 158 °F) |
| Storage temperature: | -40 ... 85 °C (-40 ... 185 °F) |
| Climatic conditions: | air humidity max. 96 % Salt spray resistant to EN 60068-2-52 |
| Shock and impact resistance: | Oscillation (Sine): 5 g, 10 - 1000 Hz to EN 60068-2-6 Shock (Half-sine): 30 g, 11 ms in accordance with EN 60068-2-27 |
| Degree of protection: | IP67 |
| Connection: | Read/write heads: shielded, 4-pin, M12 connector Power supply: M12 connector Protective earth: M4 earthing screw Diagnostic RS 232: M8 connector CC-Link: M12 connector, A-coded |
| Material: Housing: | powder coated aluminum |
| Installation: | screw fixing |
| Mass: | approx. 300 g |
| ECCN: | |
| Kraj pochodzenia: | Singapur |
| EAN: | 4050143030828 |
| Waga: | 0,45 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |