Pepperl+Fuchs 216181

VBG-PN-K20-D

AS-Interface gateway

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

PROFINET Gateway with integrated switchfa. The VBG-PN-K20-D is a PROFINET Gateway in accordance with AS-Interface Specification 3.0, to IP20, and is used for the connection of AS-Interface systems to the higher level PROFINET controller. Its construction is particularly suitable for use in the control cabinet. The master is supplied from the AS-Interface cable. On the AS-Interface gateway with graphics display, the commissioning of the AS-Interface circuit and also the test of the connected peripherals can be completely separated from the commissioning of the PROFINET and the programming. All the options available on the AS-Interface can be addressed via Ethernet. Local operation using the graphics displays and the 4 buttons enable all the functions to be represented on the display, which are covered by the other AS-Interface masters via the AS-i Control Tools software. An additional RS 232 socket provides the option of reading out data via gateway, network and function, direct from the gateway in the context of an extended local diagnosis. 7 LEDs, which are mounted on the front, indicate the current status of the AS-Interface network. Every PROFINET gateway is supplied with a unique MAC-ID and supports the assignment of an IP address statically (via keypad) and dynamically (DHCP, Dynamic Host Configuration Protocol).

Parametry techniczne

AS-Interface specification: V3.0
Duplicate address detection: from AS-Interface slaves
Earth fault detection: integrated
EMC monitoring: integrated
Diagnostics function: Extended function via display
UL File Number: E223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source
MTTFd: 105 a at 30 °C
Display: Illuminated graphical LC display for addressing and error messages
LED ETHERNET: ethernet active; LED green
LED AS-i ACTIVE: AS-Interface operation normal; LED green
LED CONFIG ERR: configuration error; LED red
LED PRG ENABLE: autom. programming; LED green
LED POWER: voltage ON; LED green
LED PRJ MODE: projecting mode active; LED yellow
LED U AS-i: AS-Interface voltage; LED green
Switch SET: Selection and setting of a slave address
OK button: Mode selection traditional-graphical/confirmation
Button MODE: Mode selection PRJ-operation/save configuration/cursor
ESC button: Mode selection traditional-graphical/cancel
Insulation voltage: ≥ 500 V
Rated operating voltage: from AS-Interface
Rated operating current: ≤ 300 mA from AS-Interface
Interface type: PROFINET I / O device (IRT)
Physical: 2 x RJ-45
Protocol: Media Redundancy Protocol (MRP)
Transfer rate: 10 MBit/s / 100 MBit/s , Automatic baud rate detection
Interface type: RS 232, serial Diagnostic Interface
Transfer rate: 19,2 kBit/s
Interface type: Chip card slot
PROFINET: RJ-45
AS-Interface: removable spring clamp terminals
Electromagnetic compatibility: Directive 2014/30/EU: EN 62026-2:2013 EN 61000-6-2:2005, EN 61000-6-4:2007
Electromagnetic compatibility: EN 61000-6-2:2005, EN 61000-6-4:2007
Degree of protection: EN 60529:2000
AS-Interface: EN 62026-2:2013
Standards: EN 61000-6-2:2005, EN 61000-6-4:2007
EAC conformity: TR CU 020/2011
UL approval: An isolated source with a secondary open circuit voltage of ≤ 30 VDC with a 3 A maximum over current protection. Over current protection is not required when a Class 2 source is employed. UL mark does not provide UL certification for any functional safety rating or aspects of the device.
Ambient temperature: 0 ... 55 °C (32 ... 131 °F)
Storage temperature: -25 ... 85 °C (-13 ... 185 °F)
Degree of protection: IP20
Mass: 500 g
Construction type: Low profile housing , Stainless steel

Parametry logistyczne

ECCN:
Kraj pochodzenia: DE
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m