Pepperl+Fuchs 209264

NBN40-U1K-E2-3G-3D

Inductive sensor

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Series: VariKont ®, Housing material: PA, Output type: 3-wire, Installation: non-flush, Type of voltage: DC, Connection type: screw terminals, Degree of protection: IP68 / IP69Kfa

Parametry techniczne

Switching function: Normally open (NO)
Output type: PNP
Rated operating distance: 40 mm
Installation: non-flush
Output polarity: DC
Assured operating distance: 0 ... 32.4 mm
Actual operating distance: 36 ... 44 mm typ. 40 mm
Reduction factor rAl: 0.31
Reduction factor rCu: 0.3
Reduction factor r304: 0.74
Reduction factor rBrass: 0.39
Output type: 3-wire
Operating voltage: 10 ... 30 V DC
Switching frequency: 0 ... 150 Hz
Hysteresis: typ. 5 %
Reverse polarity protection: reverse polarity protected
Short-circuit protection: pulsing
Voltage drop: ≤ 2 V
Voltage drop at IL: Voltage drop IL = 1 mA, switching element on: 0.5 ... 2.3 V typ. 0.9 V
Voltage drop at IL: Voltage drop IL = 10 mA, switching element on: 0.8 ... 2.2 V typ. 1.4 V
Voltage drop at IL: Voltage drop IL = 20 mA, switching element on: 0.9 ... 2.3 V typ. 1.5 V
Voltage drop at IL: Voltage drop IL = 50 mA, switching element on: 0.9 ... 2.5 V typ. 1.6 V
Voltage drop at IL: Voltage drop IL = 100 mA, switching element on: 1 ... 2.6 V typ. 1.8 V
Voltage drop at IL: Voltage drop IL = 200 mA, switching element on: 1.2 ... 2.8 V typ. 2 V
Operating current: 0 ... 200 mA
Off-state current: 0 ... 0.5 mA typ. 0.01 mA
Voltage drop at IL: Off-state current TU =40 °C, switching element off: ≤ 100 µA
No-load supply current: ≤ 20 mA
Time delay before availability: 80 ms
Operating voltage indicator: LED, green
Switching state indicator: LED, yellow
MTTFd: 1358 a
Mission Time (TM): 20 a
Diagnostic Coverage (DC): 0 %
Standard conformity: Standards: EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
FM approval: hazardous (classified) location Non-incendive
UL approval: cULus Listed, General Purpose
CCC approval: CCC approval / marking not required for products rated ≤36 V
Ambient temperature: -25 ... 85 °C (-13 ... 185 °F)
Connection type: screw terminals
Information for connection: A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %
Core cross-section: up to 2.5 mm2 , stripped insulation length: 7 mm
Standard conformity: Minimum core cross-section: min. 0.5 mm2 (incl. wire-end ferrules when using flexible conductors)
Standard conformity: Maximum core cross-section: max. 2.5 mm2 (incl. wire-end ferrules when using flexible conductors)
Connection (system side): screw terminals , M20 x 1.5 cable gland , usable thread length 9.1 mm , screw-in depth max. 9.1 mm
Housing material: PA
Sensing face: PA
Degree of protection: IP68 / IP69K
Mass: 225 g
Note: Tightening torque: 1.8 Nm (housing)
Use in the hazardous area: see instruction manuals

Parametry logistyczne

ECCN:
Kraj pochodzenia: ID
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m