Pepperl+Fuchs 184675

NCN30+U4+N0

Inductive sensor

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Series: VariKont ®, Housing material: PBT/metal, Output type: 2-wire, Installation: non-flush, Type of voltage: DC, Connection type: screw terminals, Degree of protection: IP68fa

Parametry techniczne

Switching function: Normally closed (NC)
Output type: NAMUR
Rated operating distance: 30 mm
Installation: non-flush
Assured operating distance: 0 ... 24.3 mm
Actual operating distance: 27 ... 33 mm typ.
Reduction factor rAl: 0.45
Reduction factor rCu: 0.42
Reduction factor r304: 0.79
Output type: 2-wire
Installation conditions: A: 10 mm
Nominal voltage: 8.2 V (Ri approx. 1 kΩ)
Switching frequency: 0 ... 150 Hz
Hysteresis: 1 ... 15 typ. 5 %
Reverse polarity protection: reverse polarity protected
Short-circuit protection: yes
Current consumption: Measuring plate not detected: min. 3 mA
Current consumption: Measuring plate detected: ≤ 1 mA
Switching state indicator: LED, yellow
Standard conformity: NAMUR: EN 60947-5-6:2000 IEC 60947-5-6:1999
Standard conformity: Electromagnetic compatibility: NE 21:2007
Standard conformity: Standards: EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012
FM approval: Control drawing: 116-0165
UL approval: Ordinary Location: E87056
UL approval: Hazardous Location: E501628
UL approval: Control drawing: 116-0451
CSA approval: cCSAus Listed, General Purpose
CCC approval: CCC approval / marking not required for products rated ≤36 V
Ambient temperature: -25 ... 100 °C (-13 ... 212 °F)
Storage temperature: -40 ... 100 °C (-40 ... 212 °F)
Connection type: screw terminals
Information for connection: A maximum of two conductors with the same core cross section may be mounted on one terminal connection! tightening torque 1.2 Nm + 10 %
Core cross-section: up to 2.5 mm2
UL approval: Minimum core cross-section: without wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2
UL approval: Maximum core cross-section: without wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2
Housing material: PBT/metal
Sensing face: PBT
Degree of protection: IP68
Note: Tightening torque: 1.8 Nm (housing)
Use in the hazardous area: see instruction manuals

Parametry logistyczne

ECCN:
Kraj pochodzenia: ID
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m