122887
VBG-CCL-G4F ASI-Ga
AS-Interface gateway
CC Link Gateway IP65fa. The VBG-CCL-G4F is a complete CC-Link master for use in the field (IP65). The gateway's G4 field housing has the same advantages as the serial master in this design. Two buttons are used for address assignment of the AS-Interface slaves and acceptance of the desired configuration. In configuration mode, all detected AS-Interface slaves are displayed on the 2-digit LCD. In normal operation, the LCD is blank unless the master detects a faulty AS-Interface slave. The LEDs, located on the front panel, show the current status of the AS-i line. PLC Functionality. The VBG-CCL-G4F provides 16 kBytes of program memory, 8 kBytes of main memory, 1024 counters and 1024 timers for PLC functionality. These capacities suffice to process the data on the AS-Interface. Thus the master can also be operated in "stand-alone" mode. The program processing time is 2 ms per 1000 word commands. The programming language is based on the STEP5 programming language. The AS-Interface CTRL functions (upload, download, start, stop, read or write internal memory) are available in expanded mode.
| AS-Interface specification: | V2.11 |
| PLC-Functionality: | integrated |
| Diagnostics function: | integrated |
| Display: | LED display, 2 digits, for addressing and error messages |
| LED SD: | CC Link send data; LED green |
| LED RD: | CC Link receive data; LED green |
| LED AS-i ACTIVE: | AS-Interface operation normal; LED green |
| LED CONFIG ERR: | configuration error; LED red |
| LED PWR: | voltage ON; LED green |
| LED L RUN: | CC link in operation; LED green |
| LED L ERR: | CC Link error; LED red |
| LED PRG ENABLE: | autom. programming; LED green |
| LED PRG MODE: | projecting mode active; LED yellow |
| LED U AS-i: | AS-Interface voltage; LED green |
| Switch SET: | Selection and setting of a slave address |
| Button MODE: | Mode selection/save configuration |
| Insulation voltage: | ≥ 500 V |
| Rated operating voltage: | from AS-Interface |
| Rated operating current: | ≤ 200 mA from AS-Interface |
| Interface type: | remote device, 3 occupied stations |
| Protocol: | according to CC-Link specification |
| Transfer rate: | 156 kBit/s up to 10 MBit/s |
| AS-Interface: | cable piercing technology |
| CC Link: | Cable gland M16 x 1.5 and cage spring terminals |
| Electromagnetic compatibility: Directive 2014/30/EU: | EN 62026-2:2013 |
| Degree of protection: | EN 60529:2000 |
| AS-Interface: | EN 62026-2:2013 |
| Ambient temperature: | 0 ... 55 °C (32 ... 131 °F) |
| Storage temperature: | -25 ... 85 °C (-13 ... 185 °F) |
| Degree of protection: | IP65 |
| Material: Housing: | PA 6 GF30 |
| Mass: | 355 g |
| Construction type: | Plastic housing with cable gland |
| ECCN: | |
| Kraj pochodzenia: | Deutschland |
| EAN: | 4050143012237 |
| Waga: | 0,39 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |