Pepperl+Fuchs 229232

VAA-2E-IER2-S-0,15M-V1

Lesekopf und Auswerteeinheit VAA-2E-IER2-S-0,15M-V1

Bajo pedido. Envíenos un correo electrónico para consultar el precio y la disponibilidad.
"ucnguBrctvdgcxgt0eqo"

Descripción

Parámetros técnicos

Detection type: magnetic
assured start-up distance: 7 mm
assured release distance: max. 40 mm
Center offset: ± 2.5 mm at distance s = 3 mm
Slave type: Safety-Slave
AS-Interface specification: V2.1
Required master specification: ≥ V2.0
Response delay: < 5 ms
UL File Number: E155795
Safety Integrity Level (SIL): SIL 3
Performance level (PL): PL e
Mission Time (TM): 20 a
PFHd: 4.29 E+8
Rated operating voltage: 26.5 ... 31.6 V from AS-Interface
Rated operating current: ≤ 30 mA
Power supply: via AS-Interface network
Electromagnetic compatibility: Directive 2014/30/EU: EN 62026-2:2013 IEC 60947-5-3:1999
Machinery Directive: Directive 2006/42/EC: EN ISO 12100-1, -2:2003 EN 1088:1995+A2:2008
Degree of protection: EN 60529:2000
AS-Interface: EN 62026-2:2013
Functional safety: ISO 13849-1:2008 (up to category 3/PL e) EN ISO 12100-1, -2:2003 EN 1088:1995+A2:2008
Profile: S-0.B
IO code: 0
ID code: B
ID1 code: F
ID2 code: E
Data bits (function via AS-Interface): Input
Machinery Directive: D0: dyn. safety code 1
Machinery Directive: D1: dyn. safety code 1
Machinery Directive: D2: dyn. safety code 2
Machinery Directive: D3: dyn. safety code 2
Parameter bits (programmable via AS-i): P0: IN1
Parameter bits (programmable via AS-i): P1: IN2
Parameter bits (programmable via AS-i): P2: IN3
Parameter bits (programmable via AS-i): P3: IN4
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
Shock and impact resistance: 30 g/11 ms
Degree of protection: IP67
Connection: with fixed cable and M12 connector, 4-pin
Material: Housing: PPS
Material: Cable: PUR
Installation: any position
Cable length: 15 cm
Life span: 100 x 106 switching cycles

Parámetros logísticos

ECCN:
País de origen: DE
EAN:
Peso: 0,00 kg
Longitud: 0,00 m
Anchura: 0,00 m
Altura: 0,00 m