103005422
SLC445-ER-1690-30-01
Multifunktional. Multifunctional. Einrichthilfe integriert. Integrated set-up tool. Sicherheitstyp 4 gemäß IEC 61496-1. Process safety with highest availability. Safety type 4 in accordance with IEC 61496-1. Prozesssicherheit bei höchster Verfügbarkeit. User-friendly parameter setting, no tools required. Anwenderfreundliche Parametrierung ohne Hilfsmittel
| EAN (European Article Number): | 4030661436364 |
| Artikelnummer (Bestellnummer): | 103005422 |
| Product name: | SLC445 Safety light curtain |
| Enclosure material: | Aluminium |
| Zertifikate: | cULus EAC |
| Produktname: | SLC445 Sicherheits-Lichtvorhang |
| Muting function: | Yes |
| Override: | Yes |
| Clock control possible: | Yes |
| Reaktionszeit, maximum: | 20 ms |
| Muting-Funktion: | Ja |
| Beam coding available: | Yes |
| Hide function: | Yes |
| Wiederanlaufsperre: | Ja |
| Integral System Diagnostics, status: | Yes |
| Integral System Diagnostics: | Yes |
| Ausblendfunktion: | Ja |
| 7-Segment Anzeige: | Ja |
| Integrierte Anzeige, Status: | Ja |
| Performance Level: | e |
| Control category to EN13849: | 4 |
| PFH-value: | 5.14 x 10-9 /h |
| Safety Integrity Level (SIL): | 3 |
| Normen, Vorschriften: | ISO 13849-1 EN 62061 |
| Safety type in accordance with IEC 61496-1: | 4 |
| Kategorie gemäß EN 13849: | 4 |
| PFH-Wert: | 5,14 x 10-9 /h |
| Range, protection field, maximum: | 10,000 mm |
| Height of the protection field: | 1,690 mm |
| Sicherheitstyp gemäß IEC 61496-1: | 4 |
| Detektionsvermögen für Probekörper: | 30 mm |
| Reichweite, Schutzfeld, minimum: | 300 mm |
| Terminal, Connector, Transmitter: | Connector plug M12, 4-pole |
| Höhe des Schutzfeldes: | 1.690 mm |
| Height of the Sensor (Receiver): | 1,781 mm |
| Anschluss, Stecker: | Steckverbinder |
| Length of sensor: | 33 mm |
| Width of sensor: | 27.8 mm |
| Länge der anschließbaren Leitung, maximum: | 100 m |
| Höhe des Sensors (Empfänger): | 1.781 mm |
| Ambient temperature, maximum: | +50 °C |
| Storage and transport temperature, minimum: | -25 °C |
| Storage and transport temperature, maximum: | +70 °C |
| Voltage type: | DC (direct current) |
| Umgebungstemperatur, minimum: | -25 °C |
| Electrical power consumption of the receiver, maximum: | 10 W |
| Electrical power consumption of the transmitter, maximum: | 5 W |
| Lager- und Transporttemperatur, maximum: | +70 °C |
| Schutzklasse: | III |
| Note (General): | Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA. |
| Schaltspannung OSSD, HIGH-Signal: | 24 V |
| Elektrische Leistungsaufnahme vom Empfänger, maximum: | 10 W |
| Elektrische Leistungsaufnahme des Senders, maximum: | 5 W |
| Ausgangsstrom, maximum: | 0,25 A |
| Ausführung: | p-schaltend |
| Lieferumfang: | Sender + Empfänger, Befestigungsset |
| Empfehlung Sicherheitsschaltgerät: | SRB-E 301 |
| Hinweis (Allgemein): | Im Fehlerfall (Unterbrechung der 0 V Leitung) fließt ein max. Leckstrom von 1 mA. |
| ECCN: | |
| Ursprungsland: | DE |
| EAN: | |
| Gewicht: | 2,88 kg |
| Länge: | 0,00 m |
| Breite: | 0,00 m |
| Höhe: | 0,00 m |