101184478
TQ 900-11
Metallgehäuse. Stellungsanzeige, robuste Ausführung, großer Anschlussraum, außenliegende Dichtmanschette. 3 Leitungseinführungen M 20 x 1.5, kein Verdrehen der Zugöse möglich. Einseitige Wirkweise / Seillänge bis 50 m
Product type description: | TQ 900-11 |
Article number (order number): | 101184478 |
EAN (European Article Number): | 4030661332826 |
eCl@ss number, Version 9.0: | 27-27-06-07 |
Certificates: | TÜV EAC |
Product name: | TQ 900 |
Standards: | IEC/EN 60947-5-1 |
Enclosure material: | Zinc die-cast |
Enclosure coating material: | painted |
Material of the contacts, electrical: | Silver |
Material of the cover: | Glass-fibre, thermoplastic |
Length of the wire, minimum: | 5 m |
Length of the wire, maximum: | 50 m |
Weight: | 1,255 g |
Indicator lamp: | Yes |
Number of openers: | 1 |
Number of shutters: | 1 |
Standards: | ISO 13849-1 |
Mission Time: | 20 Year(s) |
B10d Normally-closed contact (NC): | 100,000 Operations |
B10d Normally open contact (NO): | 100,000 Operations |
Mechanical life, minimum: | 1,000,000 Operations |
Actuating force, maximum: | 200 N |
Actuating travel: | 400 mm |
Terminal Connector: | Screw connection |
Cable section, minimum: | 0.75 mm² |
Cable section, maximum: | 1 x 2.5 mm² |
Note (Cable section): | All indications about the cable section are including the conductor ferrules. |
Height of the Sensor, minimum: | 220.3 mm |
Height of the Sensor, maximum: | 236.3 mm |
Length of sensor: | 69.7 mm |
Width of sensor: | 71.5 mm |
Protection class: | IP 67 to IEC/EN 60529 |
Ambient temperature, minimum: | -25 °C |
Ambient temperature, maximum: | +70 °C |
Rated impulse withstand voltage: | 6 kV |
Thermal test current: | 6 A |
Utilisation category AC-15: | 230 VAC |
Utilisation category AC-15: | 4 A |
Utilisation category DC-13: | 24 VDC |
Utilisation category DC-13: | 1 A |
Switching element: | NO contact, NC contact |
Switching principle: | Creep circuit element |
Note (General): | For lengths of over 10 m, intermediate wire supports must be installed every 3 to 5 m. Recommended cable lengths for pull-wire Emergency-Stop switches in relation to the range of ambient temperature. As the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. After that, the wire must be re-tensioned using the eyebolt or the tensioner. The screwed G24-M20 indicator lamp must be ordered separately, see accessories. |