101165883
SE-304 C AUSWERTEGERAET
1 Signalling output. 1 Meldeausgang. 1 Sicherheitskontakt, STOP 0. 1 safety contact, STOP 0. Zur Überwachung von 1 .. 4 Sicherheits-Schaltleiste(n). To monitor 1 .. 4 safety edge(s)
EAN (European Article Number): | 4030661293622 |
Artikelnummer (Bestellnummer): | 101165883 |
Enclosure material: | Glass-fibre, thermoplastic |
eCl@ss Nummer, Version 9.0: | 27-37-18-19 |
Reaction time, maximum: | 17 ms |
Produktname: | SE-304C |
Electronic Fuse: | Yes |
Klimabeanspruchung: | EN ISO 13856-2 |
Werkstoff des Gehäuses: | Kunststoff, Thermoplast |
Gewicht: | 175 g |
Feedback circuit: | Yes |
Automatic reset function: | Yes |
Reset edge detection: | Yes |
Drahtbrucherkennung: | Ja |
Querschlusserkennung: | Ja |
Integral System Diagnostics, status: | Yes |
Number of LEDs: | 5 |
Number of undelayed semi-conductor outputs with signaling function: | 1 |
Reset Flankendetektion: | Ja |
Rücksetzung nach Unterbrechung der Versorgungsspannung: | Ja |
Performance Level: | d |
Integrierte Anzeige, Status: | Ja |
Control category to EN954: | 3 |
PFH-value: | 1.01 x 10⁻⁷ /h |
Note (PFH-value): | up to max. 5,000 switching cycles/year |
Anzahl der Meldeausgänge: | 1 |
Mounting: | Snaps onto standard DIN rail to EN 60715 |
Kategorie gemäß EN 13849: | 3 |
Kategorie gemäß EN 954: | 3 |
Length of cable: | 200 m |
Hinweis (PFH-Wert): | bis max. 5.000 Schaltzyklen/Jahr |
Gebrauchsdauer: | 20 Jahre |
Befestigung: | Schnellbefestigung für Normschiene nach DIN EN 60715 |
Depth: | 121 mm |
Anschluss, Stecker: | Schraubanschluss |
Länge der Leitung: | 200 m |
Resistance to vibrations to EN 60068-2-6: | 10 … 55 Hz, amplitude 0.15 mm |
Rated impulse withstand voltage: | 4 kV |
Breite: | 22,5 mm |
Höhe: | 100 mm |
Tiefe: | 121 mm |
Rated control voltage at AC 50 Hz, maximum: | 28.8 VAC |
Rated AC voltage for controls at DC minimum: | 21.6 VDC |
Rated control voltage at DC, maximum: | 28.8 VDC |
Umgebungstemperatur, minimum: | +5 °C |
Umgebungstemperatur, maximum: | +55 °C |
Schwingungsfestigkeit nach EN 60068-2-6: | 10 … 55 Hz, Amplitude 0,15 mm |
Bemessungsstoßspannungsfestigkeit: | 4 kV |
Electrical power consumption, maximum: | 4 W |
Pull-in delay at RESET: | 100 ms ... 2000 ms |
Indicated operating states: | Authorised operation fault indication |
Bemessungsbetriebsspannung: | 24 VDC +20% / -10% 24 VAC +10% / -10% |
Note (General): | The overall machine safety depends on the professional mounting and installation of the safety monitoring module and the signal transmitter, as well as on the correct and professional electrical connection of the components. If there it any risk whatsoever, the machine may not be restarted. |
Note (Wiring diagram): | Both re-initialisation and auto-reset must comply with the requirements of EN 1760-2 (diagram A2, A3). The wiring diagram is shown for the de-energised condition. Monitoring the safety edges SE 40 / SE 70 with a safety monitoring unit SE-304C up to PL d and Category 3. Manual reset function or auto-reset: the manual reset function is triggered by an edge-sensitive signal (edge switching "0-1-0" within 100 ms up to 2 s) (X2/X3). Alternatively, the auto-reset function can be activated by a connection (A3/X2). If less than 4 safety edges are connected, the following diagram must be observed. |
Bemessungssteuerspeisespannung bei AC 50 Hz, maximum: | 28,8 VAC |
Bemessungssteuerspeisespannung bei DC, minimum: | 21,6 VDC |
Bemessungssteuerspeisespannung bei DC, maximum: | 28,8 VDC |
Spannung, Gebrauchskategorie AC-15: | 230 VAC |
Strom, Gebrauchskategorie AC-15: | 2 A |
Spannung, Gebrauchskategorie DC-13: | 24 VDC |
Strom, Gebrauchskategorie DC-13: | 2 A |
Elektrische Leistungsaufnahme, maximum: | 4 W |
Auszugsverzögerung bei RESET: | 100 ms ... 2000 ms |
Störfestigkeit: | EMV-Richtlinie |
Angezeigte Funktionszustände: | Freigabe Störungsanzeige |
Hinweis (Applikationsanwendungen): | Sicherheits-Schaltleisten |
Hinweis (Allgemein): | Die Gesamtsicherheit der Maschine ist von der fachgerechten Montage und Installation von Sicherheitsbaustein und Signalgeber, sowie von der fachgerechten elektrischen Verbindung der Baugruppen abhängig. Bei bestehender Gefahr darf die Maschine nicht erneut gestartet werden. |
Hinweis (Schaltungsbeispiel): | Manueller Reset und Autoreset muss den Anforderungen der EN 1760-2 (Zustandsdiagramm A2, A3) entsprechen. Das Schaltungsbeispiel ist im spannungslosen Zustand dargestellt. Überwachung der Sicherheits-Schaltleisten SE 40 / SE 70 mit einem Sicherheitsbaustein SE-304C bis zu PL d und Kategorie 3. Wahlweise Rückstellfunktion oder Autoreset: Die Rückstellfunktion wird durch ein flankensensitives Signal (Flankenwechsel "0-1-0" innerhalb von 100 ms bis 2 s) ausgelöst (X2/X3). Alternativ kann die Autoresetfunktion durch durch eine Verbindung (A3/X2) aktiviert werden. Werden weniger als 4 Schaltleisten angeschlossen, ist nach dem folgenden Schema anzuschließen. |
ECCN: | |
Ursprungsland: | CZ |
EAN: | |
Gewicht: | 0,18 kg |
Länge: | 0,00 m |
Breite: | 0,00 m |
Höhe: | 0,00 m |