IA0344
IAS-30-6.5-N-D6.5-PEEK-Z02-0-1G-1D
Inductive Sensors with ATEX Certificate. Inductive Sensors according to NAMUR EN 60947-5-6 for use in areas with risk of explosion. ATEX Zone 20 (Dust) and 0 (Gas). Both variants are available for flush and non-flush mounting in metal. Different body sizes available from 6.5 mm in diameter up to M32 x 1,5. ATEX Zone 20 Zone 0. Namur
| Thread / Process connection: | Ø 6,5 mm |
| Housing material active surface: | PEEK (FDA 21 CFR 177.2415) |
| Housing material: | PEEK (FDA 21 CFR 177.2415) |
| Housing material lid: | PA / PPO |
| Electrical version: | 2-Leiter DC |
| Permitted residual ripple max.: | 5% |
| Frequency of operating cycles max.: | 500 Hz |
| Protective circuit: | Eingebaut |
| Degree of protection IEC 60529: | IP 67 |
| Norm: | EN 60947-5-6 |
| Selfinductance (L): | 2 mH |
| Selfcapacitance (C): | 250 nF |
| Operating current active surface free: | > typ. 2 mA |
| Operating current active surface covered: | < typ. 1,5 mA |
| Sensing dinstance Sn: | 1,5 mm |
| Operating voltage: | 5…15 V DC, Ui = 15 V DC |
| Permitted ambient temperature min.: | -20 °C |
| Permitted ambient temperature max.: | +70 °C |
| Installation: | Bündig |
| Output function: | NAMUR |
| Cable length: | 2 m |
| Connection: | PVC-Kabel, 2 x 0,14 mm² |
| CE: | JA |
| RoHS: | JA |
| ATEX product marking dust: | Ex II 1D Ex ia Ex IIIC T 101°C Da |
| ATEX product marking gas: | Ex II 1G Ex ia Ex IIC T1 – T6 Ga |
| Certified Zones ATEX: | 1G1D |
| IECEX product marking dust: | Ex ia IIIC T101° Da |
| IECEX product marking gas: | Ex ia IIC T1 – T6 Ga |
| MTTF: | 3664,46 Jahre |
| WHG certification: | Auf Anfrage |
| ECCN: | |
| Ursprungsland: | |
| EAN: | |
| Gewicht: | 0,00 kg |
| Länge: | 0,00 m |
| Breite: | 0,00 m |
| Höhe: | 0,00 m |