2593380000
RCMA-B22-D125-1.5
| Type: | RCMA-B22-D125-1.5 |
| Order No.: | 2593380000 |
| Version: | Rogowski coil, Diameter: 125 mm, Cable length: 1.5 m |
| GTIN (EAN): | 4050118647808 |
| Qty.: | 1 pc(s). |
| Net weight: | 125 g |
| Diameter: | 125 mm |
| Humidity at operating temperature: | 5 - 90 %, no condensation |
| Operating temperature, max.: | 80 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...80 °C |
| Storage temperature: | -40 °C...80 °C |
| Installation location: | Indoor use |
| Type of conductor: | Insulated conductor only |
| Primary current: | 5,000 A |
| Tolerance class: | 0,5 |
| Cable diameter: | 6.1 mm |
| Cable length: | 1.5 m |
| Coil resistance: | 81 Ω |
| Protection degree: | IP57 |
| Linearity: | no linearity error |
| Standard: | IEC 61010-1: 2010, IEC 61869-1: 2007, IEC 61869-2: 2012, IEC 61869-6: 2016, IEC 61869-10: 2017, UL 61010-1 |
| Clearance & creepage distances: | >16 mm |
| Impulse withstand voltage: | 12.8 kV (1.2/50 ms) |
| Standard: | IEC 61010-1: 2010, IEC 61869-1: 2007, IEC 61869-2: 2012, IEC 61869-6: 2016, IEC 61869-10: 2017, UL 61010-1 |
| ETIM 6.0: | EC002475 |
| ETIM 7.0: | EC002475 |
| eClass 9.0: | 27-21-01-23 |
| eClass 9.1: | 27-21-01-23 |
| eClass 10.0: | 27-21-01-23 |
| ROHS: | Conform |
| Type: | RCMA-B22-D125-1.5 |
| Order No.: | 2593380000 |
| Version: | Rogowski coil, Diameter: 125 mm, Cable length: 1.5 m |
| GTIN (EAN): | 4050118647808 |
| Qty.: | 1 pc(s). |
| Net weight: | 125 g |
| Diameter: | 125 mm |
| Humidity at operating temperature: | 5 - 90 %, no condensation |
| Operating temperature, max.: | 80 °C |
| Operating temperature, min.: | -40 °C |
| Storage temperature, max.: | 80 °C |
| Storage temperature, min.: | -40 °C |
| Operating temperature: | -40 °C...80 °C |
| Storage temperature: | -40 °C...80 °C |
| Installation location: | Indoor use |
| Type of conductor: | Insulated conductor only |
| Primary current: | 5,000 A |
| Tolerance class: | 0,5 |
| Cable diameter: | 6.1 mm |
| Cable length: | 1.5 m |
| Coil resistance: | 81 Ω |
| Protection degree: | IP57 |
| Linearity: | no linearity error |
| Standard: | IEC 61010-1: 2010, IEC 61869-1: 2007, IEC 61869-2: 2012, IEC 61869-6: 2016, IEC 61869-10: 2017, UL 61010-1 |
| Clearance & creepage distances: | >16 mm |
| Impulse withstand voltage: | 12.8 kV (1.2/50 ms) |
| Standard: | IEC 61010-1: 2010, IEC 61869-1: 2007, IEC 61869-2: 2012, IEC 61869-6: 2016, IEC 61869-10: 2017, UL 61010-1 |
| ETIM 6.0: | EC002475 |
| ETIM 7.0: | EC002475 |
| eClass 9.0: | 27-21-01-23 |
| eClass 9.1: | 27-21-01-23 |
| eClass 10.0: | 27-21-01-23 |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,13 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |