2456200000
ACT20X-HUI-SAO-P
| Type: | ACT20X-HUI-SAO-P |
| Order No.: | 2456200000 |
| Version: | EX signal isolating converter, Ex-output: U, I, R,ϑ, Safe-output: 4-20mA/ relay, 1-channel |
| GTIN (EAN): | 4050118471601 |
| Qty.: | 1 pc(s). |
| Width: | 22.5 mm |
| Width (inches): | 0.886 inch |
| Height: | 127.3 mm |
| Height (inches): | 5.012 inch |
| Depth: | 114.6 mm |
| Depth (inches): | 4.512 inch |
| Net weight: | 202 g |
| Humidity: | 0...95 % (no condensation) |
| Operating temperature, max.: | 60 °C |
| Operating temperature, min.: | -20 °C |
| Storage temperature, max.: | 85 °C |
| Storage temperature, min.: | -20 °C |
| Operating temperature: | -20 °C...60 °C |
| Storage temperature: | -20 °C...85 °C |
| REACH SVHC: | Lead 7439-92-1 |
| Input current: | 0...20 mA, 4...20 mA |
| Input resistance: | configurable, 0…10 kΩ |
| Input resistance, current: | 20 Ω + PTC 50 Ω |
| Input resistance, voltage: | > 10 MΩ @ 600 mV, 2 MΩ @ 28 V |
| Input voltage: | configurable, 0…1 V DC, 0,2…1 V DC, 1…5 V DC, 0...(5)10 V, 2…10 V DC |
| Line resistance in measuring circuit: | ≤ 50 Ω |
| Potentiometer: | 10 Ω…10 kΩ |
| Sensor: | 2-/3-/4-wire, RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Thermocouples: B, E, J, K, N, R, S, T ; in compliance with IEC 60584-1 and L, U in compliance with DIN43710, Potentiometer, Resistance: 0 - 12 kΩ |
| Temperature input range: | Adjustable from -200...+800°C |
| Type: | intrinsically safe circuit, active (as current source) or passive (as current sink) |
| Type: | active (as current source) or passive (as current sink) |
| Influence of load resistance: | ≤ 0.01% of span / 100 Ω |
| Output signal limit: | 3.8…20.5 mA / 0…20.5 mA (dependent on range) |
| Output current: | 0…23 mA, configurable: 0…20 / 4…20 / 20…0 / 20…4 mA, configurable downscale (3.5 mA) ⁄ upscale (23 mA) @ error |
| Load impedance current: | ≤ 600 Ω |
| Alarm function: | No supply voltage, Device error |
| Type: | Relay, 1 NC (voltage-free) |
| Continuous current: | ≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2) |
| Voltage supply: | 19.2…31.2 V DC |
| Type of connection: | PUSH IN |
| Power consumption: | ≤ 2.1 W |
| Protection degree: | IP20 |
| Humidity: | 0...95 % (no condensation) |
| EMC standards: | DIN EN 61326, NE 21 |
| Insulation voltage: | 2.6 kV (input / output) |
| Rated voltage: | 300 V |
| Type: | Relay, 1 NO / NC contact |
| Continuous current: | ≤ 2 A AC/DC (safe area, Zone 2 area) |
| Function: | Configurable switching thresholds, Sensor error, Window function |
| Voltage U0: | 8.7 V DC |
| Current I0: | 18.4 mA |
| Power P0: | 40 mW |
| Marking: | II (1) G [Ex ia Ga] IIC/IIB/IIA, I (M1) [Ex ia Ma] I, II (1) G [Ex ia Ga] IIC, II (1) D [Ex ia Da] IIIC |
| Installation location: | Device installed in safe area, zone 2 |
| Demand mode: | High |
| Demand rate: | 3,000 s |
| Demand response time: | Signal input: < 0.5 s (opto output), Temperature input: < 1.1 s (opto output) |
| Description of the "safe state": | analogue Output ≤ 3.6 mA or output ≥ 21 mA, de-energized (relay output) |
| Device type: | B |
| Diagnostic test interval: | 30 s |
| Hardware fault tolerance (HFT): | 0 |
| Mean Time To Repair (MTTR): | 24 h |
| Relay lifetime: | 100000 times |
| Safe Failure Fraction (SFF): | 93 % |
| Tproof: | 4 Years |
| Total failure rate for dangerous detected failures (λDD): | 352 FIT |
| Total failure rate for dangerous undetected failures (λDU): | 43 FIT |
| Total failure rate for safe detected failures (λSD): | 0 FIT |
| Total failure rate for safe undetected failures (λSU): | 278 FIT |
| Safety category: | SIL 2 |
| Type of connection: | PUSH IN |
| Wire connection cross section AWG, min.: | AWG 26 |
| Wire connection cross section AWG, max.: | AWG 14 |
| Wire cross-section, solid, min.: | 0.2 mm² |
| Wire cross-section, solid, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded, min.: | 0.2 mm² |
| Wire connection cross section, finely stranded, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: | 0.2 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: | 2.5 mm² |
| ETIM 6.0: | EC002653 |
| ETIM 7.0: | EC002653 |
| eClass 9.0: | 27-21-01-20 |
| eClass 9.1: | 27-21-01-90 |
| eClass 10.0: | 27-21-01-20 |
| ROHS: | Conform |
| Type: | ACT20X-HUI-SAO-P |
| Order No.: | 2456200000 |
| Version: | EX signal isolating converter, Ex-output: U, I, R,ϑ, Safe-output: 4-20mA/ relay, 1-channel |
| GTIN (EAN): | 4050118471601 |
| Qty.: | 1 pc(s). |
| Width: | 22.5 mm |
| Width (inches): | 0.886 inch |
| Height: | 127.3 mm |
| Height (inches): | 5.012 inch |
| Depth: | 114.6 mm |
| Depth (inches): | 4.512 inch |
| Net weight: | 202 g |
| Humidity: | 0...95 % (no condensation) |
| Operating temperature, max.: | 60 °C |
| Operating temperature, min.: | -20 °C |
| Storage temperature, max.: | 85 °C |
| Storage temperature, min.: | -20 °C |
| Operating temperature: | -20 °C...60 °C |
| Storage temperature: | -20 °C...85 °C |
| REACH SVHC: | Lead 7439-92-1 |
| Input current: | 0...20 mA, 4...20 mA |
| Input resistance: | configurable, 0…10 kΩ |
| Input resistance, current: | 20 Ω + PTC 50 Ω |
| Input resistance, voltage: | > 10 MΩ @ 600 mV, 2 MΩ @ 28 V |
| Input voltage: | configurable, 0…1 V DC, 0,2…1 V DC, 1…5 V DC, 0...(5)10 V, 2…10 V DC |
| Line resistance in measuring circuit: | ≤ 50 Ω |
| Potentiometer: | 10 Ω…10 kΩ |
| Sensor: | 2-/3-/4-wire, RTD: PT10, PT20, PT50, PT100, PT250, PT300, PT400, PT500, PT1000, Ni50, Ni100, Ni120, Ni1000, Thermocouples: B, E, J, K, N, R, S, T ; in compliance with IEC 60584-1 and L, U in compliance with DIN43710, Potentiometer, Resistance: 0 - 12 kΩ |
| Temperature input range: | Adjustable from -200...+800°C |
| Type: | intrinsically safe circuit, active (as current source) or passive (as current sink) |
| Type: | active (as current source) or passive (as current sink) |
| Influence of load resistance: | ≤ 0.01% of span / 100 Ω |
| Output signal limit: | 3.8…20.5 mA / 0…20.5 mA (dependent on range) |
| Output current: | 0…23 mA, configurable: 0…20 / 4…20 / 20…0 / 20…4 mA, configurable downscale (3.5 mA) ⁄ upscale (23 mA) @ error |
| Load impedance current: | ≤ 600 Ω |
| Alarm function: | No supply voltage, Device error |
| Type: | Relay, 1 NC (voltage-free) |
| Continuous current: | ≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2) |
| Voltage supply: | 19.2…31.2 V DC |
| Type of connection: | PUSH IN |
| Power consumption: | ≤ 2.1 W |
| Protection degree: | IP20 |
| Humidity: | 0...95 % (no condensation) |
| EMC standards: | DIN EN 61326, NE 21 |
| Insulation voltage: | 2.6 kV (input / output) |
| Rated voltage: | 300 V |
| Type: | Relay, 1 NO / NC contact |
| Continuous current: | ≤ 2 A AC/DC (safe area, Zone 2 area) |
| Function: | Configurable switching thresholds, Sensor error, Window function |
| Voltage U0: | 8.7 V DC |
| Current I0: | 18.4 mA |
| Power P0: | 40 mW |
| Marking: | II (1) G [Ex ia Ga] IIC/IIB/IIA, I (M1) [Ex ia Ma] I, II (1) G [Ex ia Ga] IIC, II (1) D [Ex ia Da] IIIC |
| Installation location: | Device installed in safe area, zone 2 |
| Demand mode: | High |
| Demand rate: | 3,000 s |
| Demand response time: | Signal input: < 0.5 s (opto output), Temperature input: < 1.1 s (opto output) |
| Description of the "safe state": | analogue Output ≤ 3.6 mA or output ≥ 21 mA, de-energized (relay output) |
| Device type: | B |
| Diagnostic test interval: | 30 s |
| Hardware fault tolerance (HFT): | 0 |
| Mean Time To Repair (MTTR): | 24 h |
| Relay lifetime: | 100000 times |
| Safe Failure Fraction (SFF): | 93 % |
| Tproof: | 4 Years |
| Total failure rate for dangerous detected failures (λDD): | 352 FIT |
| Total failure rate for dangerous undetected failures (λDU): | 43 FIT |
| Total failure rate for safe detected failures (λSD): | 0 FIT |
| Total failure rate for safe undetected failures (λSU): | 278 FIT |
| Safety category: | SIL 2 |
| Type of connection: | PUSH IN |
| Wire connection cross section AWG, min.: | AWG 26 |
| Wire connection cross section AWG, max.: | AWG 14 |
| Wire cross-section, solid, min.: | 0.2 mm² |
| Wire cross-section, solid, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded, min.: | 0.2 mm² |
| Wire connection cross section, finely stranded, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: | 0.2 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: | 2.5 mm² |
| ETIM 6.0: | EC002653 |
| ETIM 7.0: | EC002653 |
| eClass 9.0: | 27-21-01-20 |
| eClass 9.1: | 27-21-01-90 |
| eClass 10.0: | 27-21-01-20 |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,21 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |