2456150000
ACT20X-2HAI-2SAO-P
| Type: | ACT20X-2HAI-2SAO-P |
| Order No.: | 2456150000 |
| Version: | EX signal isolating converter, Ex-input: 4 - 20 mA, Safe-output: 4-20mA, 2-channel |
| GTIN (EAN): | 4050118471281 |
| Qty.: | 1 pc(s). |
| Width: | 22.5 mm |
| Width (inches): | 0.886 inch |
| Height: | 127.3 mm |
| Height (inches): | 5.012 inch |
| Depth: | 114.6 mm |
| Depth (inches): | 4.512 inch |
| Net weight: | 212 g |
| Humidity: | 0...95 % (no condensation) |
| Operating temperature, max.: | 60 °C |
| Operating temperature, min.: | -20 °C |
| Storage temperature, max.: | 85 °C |
| Storage temperature, min.: | -20 °C |
| Operating temperature: | -20 °C...60 °C |
| Storage temperature: | -20 °C...85 °C |
| MTBF: | 315 Years |
| REACH SVHC: | Lead 7439-92-1 |
| Input current: | 4…20mA |
| Output signal in case of wire break: | < 1 mA |
| Sensor supply: | 3.8…26 V DC |
| Type: | intrinsically safe circuit, active (as current source) or passive (as current sink) |
| Voltage drop not powered: | < 6 V |
| Voltage drop powered: | < 4.5 V |
| Load stability: | ≤ 0.01 % of end value / 100 Ω |
| Type: | active (as current source) or passive (as current sink) |
| Influence of load resistance: | ≤ 0.01% of span / 100 Ω |
| 2-wire supply: | ≤ 26 V DC |
| Output signal limit: | < 28 mA |
| Output current: | 4...20 mA |
| Load impedance current: | ≤ 600 Ω |
| Alarm function: | Signal limit exceeded, Line interruption at the input, No supply voltage, Device error |
| Type: | Relay, 1 NC (voltage-free) |
| Continuous current: | ≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2) |
| Configuration: | With FDT/DTM software |
| Voltage supply: | 19.2…31.2 V DC |
| Type of connection: | PUSH IN |
| Power consumption: | ≤ 1.9 W |
| Accuracy: | < 0.1% span |
| Temperature coefficient: | < 0.01% of span/°C (TU) |
| Step response time: | ≤ 5 ms |
| Protection degree: | IP20 |
| Humidity: | 0...95 % (no condensation) |
| EMC standards: | DIN EN 61326, NE 21 |
| Insulation voltage: | 2.6 kV (input / output) |
| Rated voltage: | 300 V |
| Voltage U0: | Current loop 28 V / externally 10 V |
| Current I0: | Current loop 93 mA / externally 10 mA |
| Power P0: | Current loop 0.65 W / externally 0.1 W |
| Marking: | II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I |
| Installation location: | Device installed in safe area, zone 2 |
| Demand mode: | High |
| Description of the "safe state": | analogue Output ≤ 3.6 mA or output ≥ 21 mA |
| Device type: | A |
| Hardware fault tolerance (HFT): | 0 |
| Mean Time To Repair (MTTR): | 24 h |
| Safe Failure Fraction (SFF): | 85 % |
| Tproof: | 5 Years |
| Total failure rate for dangerous detected failures (λDD): | 127 FIT |
| Total failure rate for dangerous undetected failures (λDU): | 48 FIT |
| Total failure rate for safe detected failures (λSD): | 0 FIT |
| Total failure rate for safe undetected failures (λSU): | 164 FIT |
| Safety category: | SIL 2 |
| Type of connection: | PUSH IN |
| Wire connection cross section AWG, min.: | AWG 26 |
| Wire connection cross section AWG, max.: | AWG 14 |
| Wire cross-section, solid, min.: | 0.2 mm² |
| Wire cross-section, solid, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded, min.: | 0.2 mm² |
| Wire connection cross section, finely stranded, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: | 0.2 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: | 2.5 mm² |
| ETIM 6.0: | EC002653 |
| ETIM 7.0: | EC002653 |
| eClass 9.0: | 27-21-01-20 |
| eClass 9.1: | 27-21-01-90 |
| eClass 10.0: | 27-21-01-20 |
| ROHS: | Conform |
| Type: | ACT20X-2HAI-2SAO-P |
| Order No.: | 2456150000 |
| Version: | EX signal isolating converter, Ex-input: 4 - 20 mA, Safe-output: 4-20mA, 2-channel |
| GTIN (EAN): | 4050118471281 |
| Qty.: | 1 pc(s). |
| Width: | 22.5 mm |
| Width (inches): | 0.886 inch |
| Height: | 127.3 mm |
| Height (inches): | 5.012 inch |
| Depth: | 114.6 mm |
| Depth (inches): | 4.512 inch |
| Net weight: | 212 g |
| Humidity: | 0...95 % (no condensation) |
| Operating temperature, max.: | 60 °C |
| Operating temperature, min.: | -20 °C |
| Storage temperature, max.: | 85 °C |
| Storage temperature, min.: | -20 °C |
| Operating temperature: | -20 °C...60 °C |
| Storage temperature: | -20 °C...85 °C |
| MTBF: | 315 Years |
| REACH SVHC: | Lead 7439-92-1 |
| Input current: | 4…20mA |
| Output signal in case of wire break: | < 1 mA |
| Sensor supply: | 3.8…26 V DC |
| Type: | intrinsically safe circuit, active (as current source) or passive (as current sink) |
| Voltage drop not powered: | < 6 V |
| Voltage drop powered: | < 4.5 V |
| Load stability: | ≤ 0.01 % of end value / 100 Ω |
| Type: | active (as current source) or passive (as current sink) |
| Influence of load resistance: | ≤ 0.01% of span / 100 Ω |
| 2-wire supply: | ≤ 26 V DC |
| Output signal limit: | < 28 mA |
| Output current: | 4...20 mA |
| Load impedance current: | ≤ 600 Ω |
| Alarm function: | Signal limit exceeded, Line interruption at the input, No supply voltage, Device error |
| Type: | Relay, 1 NC (voltage-free) |
| Continuous current: | ≤ 0.5 A AC / 0.3 A DC (safe zone), ≤ 0,5 A AC / 1 A DC (zone 2) |
| Configuration: | With FDT/DTM software |
| Voltage supply: | 19.2…31.2 V DC |
| Type of connection: | PUSH IN |
| Power consumption: | ≤ 1.9 W |
| Accuracy: | < 0.1% span |
| Temperature coefficient: | < 0.01% of span/°C (TU) |
| Step response time: | ≤ 5 ms |
| Protection degree: | IP20 |
| Humidity: | 0...95 % (no condensation) |
| EMC standards: | DIN EN 61326, NE 21 |
| Insulation voltage: | 2.6 kV (input / output) |
| Rated voltage: | 300 V |
| Voltage U0: | Current loop 28 V / externally 10 V |
| Current I0: | Current loop 93 mA / externally 10 mA |
| Power P0: | Current loop 0.65 W / externally 0.1 W |
| Marking: | II (1) G [Ex ia Ga] IIC/IIB/IIA, II (1) D [Ex ia Da] IIIC, I (M1) [Ex ia Ma] I |
| Installation location: | Device installed in safe area, zone 2 |
| Demand mode: | High |
| Description of the "safe state": | analogue Output ≤ 3.6 mA or output ≥ 21 mA |
| Device type: | A |
| Hardware fault tolerance (HFT): | 0 |
| Mean Time To Repair (MTTR): | 24 h |
| Safe Failure Fraction (SFF): | 85 % |
| Tproof: | 5 Years |
| Total failure rate for dangerous detected failures (λDD): | 127 FIT |
| Total failure rate for dangerous undetected failures (λDU): | 48 FIT |
| Total failure rate for safe detected failures (λSD): | 0 FIT |
| Total failure rate for safe undetected failures (λSU): | 164 FIT |
| Safety category: | SIL 2 |
| Type of connection: | PUSH IN |
| Wire connection cross section AWG, min.: | AWG 26 |
| Wire connection cross section AWG, max.: | AWG 14 |
| Wire cross-section, solid, min.: | 0.2 mm² |
| Wire cross-section, solid, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded, min.: | 0.2 mm² |
| Wire connection cross section, finely stranded, max.: | 2.5 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, min.: | 0.2 mm² |
| Wire connection cross-section, finely stranded with wire-end ferrules DIN 46228/4, max.: | 2.5 mm² |
| ETIM 6.0: | EC002653 |
| ETIM 7.0: | EC002653 |
| eClass 9.0: | 27-21-01-20 |
| eClass 9.1: | 27-21-01-90 |
| eClass 10.0: | 27-21-01-20 |
| ROHS: | Conform |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,218 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |