103016752
AZM201Z-SK-T-1P2PW-A
Manual release. Intelligent diagnosis. Thermoplastic enclosure. 3 LEDs to show operating conditions. Max. length of the sensor chain 200 m. Suitable for hinged and sliding guards. Self-monitoring series-wiring of 31 sensors. RFID-technology for needs-based protection against, tampering. Sensor technology permits an offset between, actuator and interlock of ± 5 mm vertically and. 3 mm horizontally
| Product type description: | AZM201Z-SK-T-1P2PW-A |
| Article number (order number): | 103016752 |
| EAN (European Article Number): | 4030661509143 |
| eCl@ss number, Version 9.0: | 27-27-26-03 |
| Product name: | AZM 201 |
| Standards: | IEC 60947-5-1 ISO 13849-1 IEC 61508 IEC 60947-5-3 ISO 14119 IEC 62061 |
| general information: | Universal coding |
| Active principle: | RFID |
| Enclosure material: | Glass-fibre, reinforced thermoplastic |
| Weight: | 590 g |
| Time to readiness, maximum: | 4,000 ms |
| Duration of risk, maximum: | 200 ms |
| Power to lock: | Yes |
| Manual release: | Yes |
| Short circuit detection: | Yes |
| Short-circuit recognition: | Yes |
| Safety functions: | Yes |
| Integral System Diagnostics, status: | Yes |
| Number of safety contacts: | 2 |
| Standards: | ISO 13849-1 IEC 62061 IEC 61508 |
| Performance Level: | e |
| Control category: | 4 |
| PFH-value: | 1.90 x 10-9 /h |
| PFD value: | 1.60 x 10⁻⁴ |
| Safety Integrity Level (SIL): | 3 |
| Mission Time: | 20 Year(s) |
| Performance Level: | d |
| Control category: | 2 |
| PFH-value: | 1.00 x 10⁻⁸ /h |
| PFD value: | 8.90 x 10⁻⁴ |
| Safety Integrity Level (SIL): | 2 |
| Mission Time: | 20 Year(s) |
| Mechanical life, minimum: | 1,000,000 Operations |
| Clamping force in accordance with ISO14119 Fzh: | 2,000 N |
| Clamping force, maximum Fmax: | 2,600 N |
| Latching force: | 30 N |
| Actuating speed, maximum: | 0.2 m/s |
| Terminal Connector: | Screw connection |
| Cable section, minimum: | 0.25 mm² |
| Cable section, maximum: | 1.5 mm² |
| Diameter of the Cable, minimum: | 23 AWG |
| Diameter of the Cable, maximum: | 15 AWG |
| Height of sensor: | 220 mm |
| Length of sensor: | 50 mm |
| Width of sensor: | 40 mm |
| Protection class: | IP66 to IEC 60529 IP67 to IEC 60529 |
| Ambient temperature, minimum: | -25 °C |
| Ambient temperature, maximum: | +60 °C |
| Storage and transport temperature, minimum: | -25 °C |
| Storage and transport temperature, maximum: | +85 °C |
| Relative humidity, minimum: | 30 % |
| Relative humidity, maximum: | 95 % |
| Note (Relative humidity): | non-condensing |
| Resistance to vibrations to EN 60068-2-6: | 10 … 150 Hz, amplitude 0.35 mm |
| Restistance to shock: | 30 g / 11 ms |
| Rated impulse withstand voltage: | 0.8 kV |
| Degree of pollution to VDE 0100: | 3 |
| Operating voltage, minimum: | 20.4 VDC |
| Operating voltage, maximum: | 26.4 VDC |
| Current: | No-load current I0, typ.: 0.6 A |
| Operating current: | 1,200 mA |
| Reaction time of actuator, maximum: | 100 ms |
| Reaction time of input, maximum: | 0.5 ms |
| Switching frequency, approx.: | 1 Hz |
| Switching thresholds of magnet inputs: | -3 V … 5 V (Low) 15 V … 30 V (High) |
| Switching thresholds of fail-safe inputs: | −3 V … 5 V (Low) 15 V … 30 V (High) |
| Rated operating current (safety outputs): | 250 mA |
| Current leakage: | 0.5 mA |
| Operating current (diagnostic output): | 50 mA |
| Note (LED switching conditions display): | Operating condition: LED green Error / functional defect: LED red Supply voltage UB: LED green |
| Included in delivery: | Actuators must be ordered separately. Triangular key for AZM 201 |
| Recommendation (actuator): | AZ/AZM201-B1 AZ/AZM201-B30 |
| Note (General): | As long as the actuating unit remains inserted in the solenoid interlock, the unlocked safety guard can be relocked. In this case, the safety outputs are re-enabled, so that the safety guard must not be opened. |
| Bemessungsbetriebsstrom: | 250 mA |
| Spannungsfall Ud, maximum: | 4 V |
| Reststrom: | 0,5 mA |
| Spannung, Gebrauchskategorie DC13: | 24 VDC |
| Strom, Gebrauchskategorie DC13: | 0,25 A |
| Klassifizierung ZVEI CB24I, Quelle: | C2 |
| Klassifizierung ZVEI CB24I, Senke: | C1 C2 |
| Bemessungsbetriebsstrom (Diagnose-Ausgang): | 50 mA |
| Spannungsfall Ud, maximum: | 4 V |
| Spannung, Gebrauchskategorie DC13: | 24 VDC |
| Strom, Gebrauchskategorie DC13: | 0,05 A |
| Hinweis (LED-Zustandsanzeige): | Betriebszustand: gelbe LED Fehler Funktionsstörung: rote LED Versorgungsspannung UB: grüne LED |
| Lieferumfang: | Die Betätiger sind nicht im Lieferumfang enthalten. Dreikantschlüssel für AZM 201 |
| Empfehlung (Betätiger): | AZ/AZM201-B1 AZ/AZM201-B30 |
| Hinweis (Allgemein): | Die entsperrte Schutzeinrichtung kann, solange die Betätigereinheit in der Sicherheitszuhaltung eingeführt bleibt, wieder gesperrt werden. Die Sicherheitsausgänge werden erneut eingeschaltet, somit ist ein Öffnen der Schutzeinrichtung nicht erforderlich. |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 0,58 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |