101213956
RSS 36-D-R-ST
Actuation from side. Thermoplastic enclosure. 27 mm x 108.2 mm x 35 mm. Misaligned actuation possible. 1 x connector socket M12, 8-pole. Universal coding with RFID technology. Max. 31 sensors can be wired in series. 2 short-circuit proof PNP safety outputs. High repeat accuracy of the switching points. RFID-technology for needs-based protection against, tampering. Integral cross-short, wire-breakage and external, voltage monitoring of the safety cables up to the, control cabinet
| Product type description: | RSS 36-D-R-ST |
| Article number (order number): | 101213956 |
| EAN (European Article Number): | 4030661405308 |
| eCl@ss number, Version 9.0: | 27-27-24-03 |
| Certificates: | TÜV cULus ECOLAB EAC FCC IC |
| Product name: | RSS 36 |
| Standards: | IEC 60947-5-3 |
| general information: | Universal coding |
| Active principle: | RFID |
| Housing construction form: | Block |
| Installation conditions (mechanical): | not flush |
| Sensor topology: | Sensor for series wiring |
| Enclosure material: | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| Active area: | Glass-fibre, reinforced thermoplastic |
| Time to readiness, maximum: | 2,000 ms |
| Reaction time, maximum: | 100 ms |
| Duration of risk, maximum: | 200 ms |
| Latching: | Yes |
| Diagnostic output: | Yes |
| Short circuit detection: | Yes |
| Short-circuit recognition: | Yes |
| Safety functions: | Yes |
| Cascadable: | Yes |
| Integral System Diagnostics, status: | Yes |
| Number of LEDs: | 3 |
| Number of semi-conductor outputs with signaling function: | 1 |
| Number of fail-safe digital outputs: | 2 |
| Standards: | ISO 13849-1 IEC 60947-5-3 EN 62061 IEC 61508 |
| Performance Level: | e |
| Control category to EN13849: | 4 |
| PFH-value: | 2.70 x 10⁻¹⁰ /h |
| Safety Integrity Level (SIL): | 3 |
| Mission Time: | 20 Year(s) |
| Actuating panels: | lateral |
| Active area: | lateral |
| Mounting: | A screw length of 25 mm is sufficient for sensor mounting and for side mounting of the actuators. 30 mm long screws are recommended when the actuator is mounted upright and/or when the sealing discs are used. |
| Switch distance: | 12 mm |
| Ensured switch distance "ON" Sao: | 10 mm |
| Ensured switch distance "OFF" Sar: | 20 mm |
| Hysteresis (Switch distance), maximum: | 2 mm |
| Repeat accuracy R R: | 0.5 mm |
| Note (Repeat accuracy R): | Axial offset: The long side allows for a maximum height misalignment (x) of sensor and actuator of 8 mm (e.g. mounting tolerance or due to guard door sagging). The axial misalignment (y) is max. ± 18 mm (see figure: Operating principle). Minimum 100 mm clearance in case of approach from side. |
| Latching force: | 18 N |
| Terminal Connector: | Connector M12, 8-pole |
| Note: | The cable section of the interconnecting cable must be observed! Cable length and cable section alter the voltage drop depending on the output current |
| Height of sensor: | 25 mm |
| Length of sensor: | 22 mm |
| Width of sensor: | 106.3 mm |
| Protection class: | IP 65 to IEC/EN 60529 IP 67 to IEC/EN 60529 IP 69 to IEC/EN 60529 |
| Ambient temperature, minimum: | -25 °C |
| Ambient temperature, maximum: | +70 °C |
| Storage and transport temperature, minimum: | -25 °C |
| Storage and transport temperature, maximum: | +85 °C |
| Material temperature resistance of the cable (in motion), minimum: | -10 °C |
| Material temperature resistance of the cable (at rest), minimum: | -30 °C |
| Material temperature resistance (long-term), maximum: | +105 °C |
| Resistance to vibrations to EN 60068-2-6: | 10 … 55 Hz, amplitude 1 mm |
| Restistance to shock: | 30 g / 11 ms |
| Rated impulse withstand voltage: | 0.8 kV |
| Degree of pollution to VDE 0100: | 3 |
| Voltage type: | DC (direct current) |
| No-load current: | 100 mA |
| Rated operating voltage: | 24 VDC −15 % / +10 % |
| Rated operating voltage, minimum: | 20.4 VDC |
| Rated operating voltage, maximum: | 26.4 VDC |
| Operating current: | 600 mA |
| Required rated short-circuit current to EN 60947-5-1: | 100 A |
| Switching frequency, approx.: | 1 Hz |
| Rated operating current (safety outputs): | 250 mA |
| Output current, (fail-safe output), maximum: | 0.25 A |
| Current leakage: | 0.5 mA |
| Note (LED switching conditions display): | LED yellow: Operating condition LED green: Supply voltage LED red: Fault |
| PIN 1: | A1 Ue Brown |
| PIN 2: | X1 Safety input 1 White |
| PIN 3: | A2 GND Blue |
| PIN 4: | Y1 Safety output 1 Black |
| PIN 5: | OUT Diagnostic output OUT Grey |
| PIN 6: | X2 Safety input 2 violet |
| PIN 7: | Y2 Safety output 2 red |
| PIN 8: | IN without function Pink |
| Included in delivery: | Actuators must be ordered separately. |
| Recommendation (actuator): | RST 36-1 RST 36-1-R |
| Note (General): | Evaluation requirements: dual-channel safety input, suitable for p-type sensors with NO function. The safety-monitoring module must tolerate internal functional tests of the sensors with cyclic switch-off of the sensor outputs for max. 2 ms. Short-circuit recognition by the evaluation is not necessary. |
| Strom, Gebrauchskategorie DC12: | 0,05 A |
| Spannung, Gebrauchskategorie DC13: | 24 VDC |
| Strom, Gebrauchskategorie DC13: | 0,05 A |
| Störaussendung: | IEC 61000-6-4 |
| Störfestigkeit: | IEC 60947-3 |
| Hinweis (LED-Zustandsanzeige): | gelbe LED: Betriebszustand grüne LED: Versorgungsspannung rote LED: Fehler |
| PIN 1: | A1 Ue: braun |
| PIN 2: | X1 Sicherheitseingang 1: weiß |
| PIN 3: | A2 GND: blau |
| PIN 4: | Y1 Sicherheitsausgang 1: schwarz |
| PIN 5: | OUT Diagnoseausgang OUT: grau |
| PIN 6: | X2 Sicherheitseingang 2: violett |
| PIN 7: | Y2 Sicherheitsausgang 2: rot |
| PIN 8: | IN ohne Funktion: rosa |
| Lieferumfang: | Die Betätiger sind nicht im Lieferumfang enthalten. |
| Empfehlung (Betätiger): | RST 36-1 RST 36-1-R |
| Empfehlung Sicherheitsschaltgerät: | PROTECT PSC1 SRB-E-301ST SRB-E-201LC |
| Hinweis (Allgemein): | Anforderungen an die Auswertung: Zweikanaliger Sicherheitseingang, geeignet für p-schaltende Sensoren mit Schließerfunktion. Die Funktionstests der Sensoren mit zyklischem Abschalten der Sensorausgänge für max. 2 ms müssen von der Auswertung toleriert werden. Eine Querschlusserkennung in der Auswertung ist nicht notwendig. |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 0,10 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |