101207211
SLC 420-E/R0330-30-RFBH
Protection class IP67. Resolution 14, 30 and 50 mm. Safety type 4 in accordance with IEC 61496-1. Protection field height from 170 mm … 1770 mm
| Product type description: | SLC 420-E/R0330-30-RFBH |
| Article number (order number): | 101207211 |
| eCl@ss number, Version 9.0: | 27-27-27-04 |
| Certificates: | TÜV cULus EAC |
| Product name: | SLC 420 Safety light curtain |
| Standards: | IEC/EN 61496-1/-2 |
| Enclosure material: | Aluminium |
| Reaction time, maximum: | 10 ms |
| Restart interlock (manual reset): | Yes |
| Beam coding available: | Yes |
| Hide function: | Yes |
| Integral System Diagnostics, status: | Yes |
| Integral System Diagnostics: | Yes |
| Number of beams: | 16 |
| Number of fail-safe digital outputs: | 2 |
| Standards: | ISO 13849-1 IEC 61508 |
| Performance Level: | e |
| Control category to EN13849: | 4 |
| PFH-value: | 6.19 x 10-9 /h |
| Safety Integrity Level (SIL): | 3 |
| Mission Time: | 20 Year(s) |
| Safety type in accordance with IEC 61496-1: | 4 |
| Detection ability for test bodies at v = 1.6 m/s: | 30 mm |
| Range, protection field, minimum: | 300 mm |
| Range, protection field, maximum: | 18,000 mm |
| Height of the protection field: | 330 mm |
| Wave length of the sensor: | 880 nm |
| Terminal Connector: | Connector |
| Terminal connector, Recipient: | Connector plug M12, 8-pole |
| Terminal, Connector, Transmitter: | Connector plug M12, 4-pole |
| Length of the connectable cable, maximum: | 100 m |
| Diameter of sensor: | 49 mm |
| Height of sensor: | 415 mm |
| Protection class: | IP 67 to IEC/EN 60529 |
| Ambient temperature, minimum: | -10 °C |
| Ambient temperature, maximum: | +50 °C |
| Storage and transport temperature, minimum: | -25 °C |
| Storage and transport temperature, maximum: | +70 °C |
| Voltage type: | DC (direct current) |
| Switching voltage OSSD, HIGH signal: | 24 V |
| Electrical power consumption of the receiver: | 8 W |
| Electrical power consumption of the transmitter: | 4 W |
| Output current, (fail-safe output), maximum: | 0.5 A |
| Included in delivery: | Kit with 2 mounting angles |
| Note (General): | Im In case of failure (interruption of the 0 V supply) the maximum leakage current is 1 mA. |
| Lieferumfang: | Sender + Empfänger, Befestigungsset |
| Empfehlung Sicherheitsschaltgerät: | SRB-E 301 |
| Hinweis (Allgemein): | Im Fehlerfall (Unterbrechung der 0 V Leitung) fließt ein max. Leckstrom von 1 mA. |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 2,07 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |