Article image 101184481

Schmersal 101184481

TQ 900-13

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Robust design. Metal enclosure. Position indicator. Large wiring compartment. External watertight collar. 3 cable entries M 20 x 1.5. Twisting of towing eye not possible, one-side operation / wire up to 50 m long

Parametry techniczne

Product type description: TQ 900-13
Article number (order number): 101184481
EAN (European Article Number): 4030661333700
eCl@ss number, Version 9.0: 27-27-06-07
Certificates: TÜV EAC
Product name: TQ 900
Standards: IEC/EN 60947-5-1
Enclosure material: Zinc die-cast
Enclosure coating material: painted
Material of the contacts, electrical: Silver
Material of the cover: Glass-fibre, thermoplastic
Length of the wire, minimum: 5 m
Length of the wire, maximum: 50 m
Weight: 1,220 g
Indicator lamp: Yes
Number of openers: 3
Number of shutters: 1
Standards: ISO 13849-1
Mission Time: 20 Year(s)
B10d Normally-closed contact (NC): 100,000 Operations
B10d Normally open contact (NO): 100,000 Operations
Mechanical life, minimum: 1,000,000 Operations
Actuating force, maximum: 200 N
Actuating travel: 400 mm
Terminal Connector: Screw connection
Cable section, minimum: 0.75 mm²
Cable section, maximum: 1 x 2.5 mm²
Note (Cable section): All indications about the cable section are including the conductor ferrules.
Height of the Sensor, minimum: 220.3 mm
Height of the Sensor, maximum: 236.3 mm
Length of sensor: 69.7 mm
Width of sensor: 71.5 mm
Protection class: IP 67 to IEC/EN 60529
Ambient temperature, minimum: -25 °C
Ambient temperature, maximum: +70 °C
Rated impulse withstand voltage: 6 kV
Thermal test current: 6 A
Utilisation category AC-15: 230 VAC
Utilisation category AC-15: 4 A
Utilisation category DC-13: 24 VDC
Utilisation category DC-13: 1 A
Switching element: NO contact, NC contact
Switching principle: Creep circuit element
Note (General): For lengths of over 10 m, intermediate wire supports must be installed every 3 to 5 m. Recommended cable lengths for pull-wire Emergency-Stop switches in relation to the range of ambient temperature. As the thimbles are subject to deformation in case of wire pull, the wire should be pulled several times after fitting. After that, the wire must be re-tensioned using the eyebolt or the tensioner. The screwed G24-M20 indicator lamp must be ordered separately, see accessories.

Parametry logistyczne

ECCN:
Kraj pochodzenia: BR
EAN:
Waga: 1,22 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m