101172062
TK 236-02ZH-M20
Slim design. Double-insulated. Thermoplastic enclosure. 30 mm x 58,5 mm x 30 mm. 1 Cable entry M 20 x 1.5. Mounting details to EN 50047. Wide range of alternative actuators. Good resistance to oil and petroleum spirit. Actuator heads can be repositioned by 4 x 90°
| Product type description: | TK 236-02ZH |
| Article number (order number): | 101172062 |
| EAN (European Article Number): | 4030661299860 |
| eCl@ss number, Version 9.0: | 27-27-26-01 |
| Certificates: | cCSAus CCC EAC |
| Product name: | T 236 offset roller lever K |
| Standards: | IEC 60947-5-1 ISO 13849-1 BG-GS-ET-15 |
| Housing construction form: | Norm construction design |
| Actuator type to DIN EN 50047: | E |
| Enclosure material: | Plastic, glass-fibre reinforced thermoplastic, self-extinguishing |
| Material of the contacts, electrical: | Silver |
| Weight: | 60 g |
| Safety functions: | Yes |
| Number of safety contacts: | 2 |
| Standards: | ISO 13849-1 |
| Mission Time: | 20 Year(s) |
| B10d Normally-closed contact (NC): | 20,000,000 Operations |
| Actuating element: | Offset roller lever |
| Mechanical life, minimum: | 20,000,000 Operations |
| Actuating force, minimum: | 9 N |
| Positive break force, minimum: | 19 N |
| Actuating speed, minimum: | 240 mm/min |
| Actuating speed, maximum: | 1 m/s |
| Note (Actuating speed): | Actuating speed with actuating angle 30° to switch axis |
| Note Bounce duration: | Bounce duration in accordance with actuating speed |
| Note (Switchover time): | Switchover time in accordance with actuating speed |
| Terminal Connector: | Screw connection |
| Cable section, minimum: | 0.75 mm² |
| Cable section, maximum: | 2.5 mm² |
| Note (Cable section): | All indications about the cable section are including the conductor ferrules. |
| Height of sensor: | 93.1 mm |
| Length of sensor: | 30 mm |
| Width of sensor: | 30 mm |
| Protection class: | IP67 |
| Ambient temperature, minimum: | -30 °C |
| Ambient temperature, maximum: | +80 °C |
| Rated impulse withstand voltage: | 6 kV |
| Thermal test current: | 10 A |
| Required rated short-circuit current to EN 60947-5-1: | 1,000 A |
| Utilisation category AC-15: | 230 VAC |
| Utilisation category AC-15: | 4 A |
| Utilisation category DC-13: | 24 VDC |
| Utilisation category DC-13: | 1 A |
| Switching element: | Opener (NC) |
| Switching principle: | Slow action with staggered contacts |
| Switching frequency: | 5,000 /h |
| ECCN: | |
| Kraj pochodzenia: | DE |
| EAN: | |
| Waga: | 0,06 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |