KA1270
KAS-40-26/113-N-G1-PEEK-HG-100C-Y5-1-1G
Capacitive Sensors ATEX. Series 40 – NAMUR EN 60947-5-6. Housing Ø 26 mm / 1” / 40 mm. For use in areas with the risk of gas explosion, zone 0. Housing material: PEEK. SIP / CIP 121 °C. Useable for an ambient temperature up to +100°C / 212°C. DMT 03 ATEX E 048 IECEx BVS 07.0031. II 1G Ex ia IIC T1-T6 Ga Ex ia IIC T1-T6 Ga
| Thread / Process connection: | G 1" |
| Housing material active surface: | PEEK (FDA 21 CFR 177.2415) |
| Housing material: | PEEK (FDA 21 CFR 177.2415) |
| Housing material lid: | PA |
| Electrical version: | 2-Polig DC |
| Permitted residual ripple max.: | 5% |
| Frequency of operating cycles max.: | 50 Hz |
| LEDdisplay: | Gelb |
| Protective circuit: | Eingebaut |
| Degree of protection IEC 60529: | IP 67 (mit versiegelter Potentiometerschraube) |
| Norm: | EN 60947-5-6 |
| Selfinductance (L): | 0,2 mH |
| Selfcapacitance (C): | 250 nF |
| Operating current active surface free: | < typ. 1,5 mA |
| Operating current active surface covered: | > typ. 3 mA |
| Sensing dinstance Sn: | produktberuehrend-mediumabhaengig-einstellbar |
| Operating distance min. / max. adjustable: | 0…15 mm |
| Operating voltage: | 5…15 V DC, Ui = 15 V DC |
| Permitted ambient temperature min.: | 0 °C |
| Permitted ambient temperature max.: | +70 °C |
| CIP / SIP: | CIP / SIP 121°C |
| Installation: | Nichtbündig |
| Output function: | NAMUR |
| Connection: | Steckerflansch M 12 x 1 |
| CE: | JA |
| RoHS: | JA |
| UL CSA certification: | JA |
| ATEX product marking gas: | Ex II 1G Ex ia Ex IIC T1 – T6 Ga |
| Certified Zones ATEX: | 1G |
| IECEX product marking gas: | Ex ia IIC T1 – T6 Ga |
| MTTF: | 1134,55 Jahre |
| WHG certification: | Auf Anfrage |
| ECCN: | |
| Kraj pochodzenia: | |
| EAN: | |
| Waga: | 0,00 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |