2906367
TRIO-UPS-2G/3AC/24DC/20
| Width: | 88 mm |
| Height: | 130 mm |
| Depth: | 160 mm |
| Width with alternative assembly: | 160 mm |
| Height with alternative assembly: | 130 mm |
| Depth with alternative assembly: | 88 mm |
| Installation distance right/left: | 0 mm / 0 mm |
| Installation distance top/bottom: | 50 mm / 50 mm |
| Degree of protection: | IP20 |
| Inflammability class in acc. with UL 94 (housing / terminal blocks): | V0 |
| Ambient temperature (operation): | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
| Ambient temperature (start-up type tested): | -40 °C |
| Ambient temperature (storage/transport): | -40 °C ... 85 °C |
| Max. permissible relative humidity (operation): | ≤ 95 % (At +25°C, non-condensing) |
| Climatic class: | 3K3 (in acc. with EN 60721) |
| Degree of pollution: | 2 |
| Installation height: | ≤ 4000 m (> 2000 m, observe derating) |
| Inrush current limiting/I²t: | < 0.76 A2s |
| Mains buffering time: | ≥ 25 ms (400 V AC) |
| Typical response time: | 200 ms |
| Input fuse, integrated: | 6.3 A (slow-blow, internal) |
| Nominal output voltage: | 24 V DC |
| Setting range of the output voltage (USet): | 24 V DC ... 28 V DC (> 24 V constant capacity) |
| Nominal output current (IN): | 20 A |
| Dynamic Boost (IDyn.Boost): | 30 A |
| Derating: | > 60 °C (2.5%/K of POut nom.) |
| Control deviation: | < 0.3 % (Static load change 10 % ... 90 %) |
| Maximum power dissipation in no-load condition: | < 3.6 W (400 V AC) |
| Efficiency: | typ. 93 % (400 V AC) |
| Residual ripple: | < 20 mV |
| Connection in parallel: | yes, with diode module uncoupled |
| Surge protection against internal surge voltages: | < 30 V DC |
| Feedback voltage resistance: | ≤ 35 V DC |
| Net weight: | 1.71 kg |
| Insulation voltage input/output: | 4 kV AC (type test) |
| Protection class: | I |
| MTBF (IEC 61709, SN 29500): | > 1108720 h (400 V AC, at 25°C) |
| Mounting position: | horizontal DIN rail NS 35, EN 60715 |
| Assembly instructions: | alignable: horizontally 0 mm, vertically 50 mm |
| Connection method: | Push-in connection |
| Conductor cross section solid min.: | 0.2 mm² |
| Conductor cross section solid max.: | 4 mm² |
| Conductor cross section flexible min.: | 0.2 mm² |
| Conductor cross section flexible max.: | 2.5 mm² |
| Conductor cross section AWG min.: | 24 |
| Conductor cross section AWG max.: | 12 |
| Stripping length: | 10 mm |
| Connection method: | Push-in connection |
| Conductor cross section solid min.: | 0.2 mm² |
| Conductor cross section solid max.: | 10 mm² |
| Conductor cross section flexible min.: | 0.2 mm² |
| Conductor cross section flexible max.: | 6 mm² |
| Conductor cross section AWG min.: | 24 |
| Conductor cross section AWG max.: | 8 |
| Stripping length: | 15 mm |
| Connection method: | Push-in connection |
| Conductor cross section solid min.: | 0.2 mm² |
| Conductor cross section solid max.: | 1.5 mm² |
| Conductor cross section flexible min.: | 0.2 mm² |
| Conductor cross section flexible max.: | 1.5 mm² |
| Conductor cross section AWG min.: | 24 |
| Conductor cross section AWG max.: | 16 |
| Stripping length: | 8 mm |
| Charge characteristic curve: | IU0U |
| Charge current: | 0.5 A ... 3 A (-25 °C ... 60 °C) |
| EMC requirements for noise immunity: | EN 61000-6-1 |
| EMC requirements for noise emission: | EN 61000-6-3 |
| Standard - safety for equipment for measurement, control, and laboratory use: | IEC 61010-1 |
| Standard – Safety extra-low voltage: | IEC 61010 (SELV) / (PELV) |
| Standard - Safe isolation: | DIN VDE 0100-410 |
| Standard - power supply devices for low voltage with DC output: | EN 61204-3 |
| UL approvals: | UL Listed UL 61010 |
| Electromagnetic compatibility: | Conformance with EMC Directive 2014/30/EU |
| Low Voltage Directive: | Conformance with Low Voltage Directive 2014/35/EC |
| Conducted noise emission: | EN 61000-6-3 (Class B) |
| Noise emission: | EN 61000-6-3 (Class B) |
| DNV GL conducted interference: | Class B |
| Additional text: | Area power distribution |
| DNV GL noise radiation: | Class B |
| Additional text: | Bridge and deck area |
| Electrostatic discharge: | EN 61000-4-2 |
| Contact discharge: | 6 kV (Test Level 4) |
| Discharge in air: | 8 kV (Test Level 4) |
| Electromagnetic HF field: | EN 61000-4-3 |
| Frequency range: | 80 MHz ... 6 GHz |
| Test field strength: | 10 V/m (Test Level 3) |
| Comments: | Criterion A |
| Fast transients (burst): | EN 61000-4-4 |
| Input: | 4 kV (Test Level 4 - asymmetrical) |
| Output: | 2 kV (Test Level 3 - asymmetrical) |
| Signal: | 2 kV (Test Level 4 - asymmetrical) |
| Comments: | Criterion A |
| Input: | 2 kV (Test Level 3 - symmetrical) |
| Output: | 1 kV (Test Level 1 - symmetrical) |
| Signal: | 1 kV (Test Level 2 - asymmetrical) |
| Comments: | Criterion A |
| Conducted interference: | EN 61000-4-6 |
| I/O/S: | asymmetrical |
| Frequency range: | 0.15 MHz ... 80 MHz |
| Voltage: | 10 V (Test Level 3) |
| Comments: | Criterion A |
| Attenuated sinusoidal oscillations (ring wave): | EN 61000-4-12 |
| Input: | 2 kV (symmetrical) |
| Comments: | Criterion A |
| Criterion A: | Normal operating behavior within the specified limits. |
| Criterion B: | Temporary impairment to operational behavior that is corrected by the device itself. |
| REACh SVHC: | Lead 7439-92-1 |
| eCl@ss 10.0.1: | 27040705 |
| eCl@ss 9.0: | 27040705 |
| ETIM 6.0: | EC000382 |
| ETIM 7.0: | EC000382 |
| ECCN: | |
| Kraj pochodzenia: | CN |
| EAN: | |
| Waga: | 2,007 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |