315197
PMI120-F90-IU2EP-IO-V15-3G-3D
Inductive positioning system
Parameterization and diagnosis via IO-Link, Measuring range 0 .. 120 mm, Parameterisable measuring range, Analog current or voltage output, programmable, 2 Push-pull outputs, Housing: PBT, stainless steel 1.4571 , brass, nickel-plated, Connection type: 5-pin, M12 x 1 connector, Type of voltage: DC, Degree of protection: IP67 / IP69Kfa
Switching element function: | Analog current or voltage output, programmable 2 switch outputs, programmable |
Object distance: | 0.5 ... 3 mm , recommended: 1.5 mm |
Measurement range: | 0 ... 120 mm |
Linearity range: | 1 ... 119 mm |
Operating voltage: | 12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized) |
Reverse polarity protection: | reverse polarity protected |
Linearity error: | within measuring range: ± 0.8 mm within linearity range: ± 0.4 mm |
Repeat accuracy: | ± 0.1 mm |
Resolution: | 50 µm |
Temperature drift: | ± 0.5 mm (-25 °C ... 70 °C) |
No-load supply current: | ≤ 40 mA |
Operating voltage indicator: | LED green |
MTTFd: | 278 a |
Mission Time (TM): | 20 a |
Diagnostic Coverage (DC): | 0 % |
LED S1: | switching state Switching output 1 |
LED S2: | switching state Switching output 2 |
LED S3: | Damping element in the configured analog measuring range |
LED STATUS: | Status display LED, green/red (Power on, communication/error, missing damping element) |
Interface type: | IO-Link (via C/Q = Pin 4) |
IO-Link Revision: | 1.1 |
Device profile: | Smart Sensor |
Device ID: | 0x200404 (2098180) |
Transfer rate: | COM 2 (38.4 kBaud) |
Value range: | 0000h ... 9600h |
Min. cycle time: | 2.3 ms |
Process data width: | Process data input: 16 Bit Process data output: none |
SIO mode support: | yes |
Compatible master port type: | A |
Output type: | 2 push-pull outputs (can be parameterized), short-circuit-proof, reverse polarity protection, surge-proof |
Operating current: | ≤ 100 mA / output |
Switching window: | ± 1 mm |
Switching hysteresis: | 0.2 mm |
Voltage drop: | ≤ 3 V |
Short-circuit protection: | pulsing |
Output type: | 1 current output: 4 ... 20 mA or 1 voltage output: 0 ... 10 V , programmable |
Load resistor: | current output: ≤ 400 Ω voltage output: ≥ 1000 Ω |
Short-circuit protection: | voltage output: current limit |
Standard conformity: Standards: | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 EN 60947-5-7:2003 EN61131-9:2013 IEC 60947-5-7:2003 IEC 61131-9:2013 |
UL approval: | cULus Listed, Class 2 Power Source, Type 1 enclosure |
Ambient temperature: | -25 ... 85 °C (-13 ... 185 °F) |
Connection type: | 5-pin, M12 x 1 connector |
Degree of protection: | IP67 / IP69K |
Material: Housing: | PBT, stainless steel 1.4571 , brass, nickel-plated |
Material: Target: | mild steel, e. g. 1.0037, SR235JR (formerly St37-2) |
Mass: | 113 g |
Equipment protection level: | Gc (nA) , Dc |
Type of protection: | "n" |
CE marking: | [*PD-Z02586A*] |
Certificates: ATEX certificate: | PF 15 CERT 3754 X |
Certificates: ATEX marking: | II 3G Ex nA IIC T6 Gc |
Certificates: Standards: | EN 60079-0:2012+A11:2013 , EN 60079-15:2010 |
Possible characteristics: | maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax |
Maximum permissible ambient temperature: | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. mode of operation 1 at UBmax = 30 V and maximum 2 switching outputs with each ILmax =100 mA and 1 analog output with IAmax = 20mA or UAmax = 10 V : 35 °C (95 °F) mode of operation 2 at UBmax = 30 V and maximum 1 switching output with ILmax =100 mA : 50 °C (122 °F) |
Type of protection: | Protection by enclosure "tc" |
CE marking: | [*PD-Z02586A*] |
Certificates: ATEX certificate: | PF 15 CERT 3774 X |
Certificates: ATEX marking: | II 3D Ex tc IIIC T80°C Dc |
Certificates: Standards: | EN 60079-0:2012/A11+2013 , EN 60079-31:2014 |
Possible characteristics: | maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax |
Maximum permissible ambient temperature: | Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. mode of operation 1 at UBmax = 30 V and maximum 2 switching outputs with each ILmax =100 mA and 1 analog output with IAmax = 20mA or UAmax = 10 V : 35 °C (95 °F) mode of operation 2 at UBmax = 30 V and maximum 1 switching output with ILmax =100 mA : 50 °C (122 °F) |
Use in the hazardous area: | see instruction manuals |
ECCN: | |
Kraj pochodzenia: | SG |
EAN: | |
Waga: | 0,00 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |