Parameterization and diagnosis via IO-Link, Measuring range 0 .. 40 mm, Parameterisable measuring range, Analog current or voltage output, programmable, 2 Push-pull outputs, Housing: PBT, stainless steel 1.4571 , brass, nickel-plated, Connection type: 5-pin, M12 x 1 connector, Type of voltage: DC, Degree of protection: IP67 / IP69Kfa

Parametry techniczne

Switching element function: Analog current or voltage output, programmable 2 switch outputs, programmable
Object distance: 0.5 ... 3 mm , recommended: 1.5 mm
Measurement range: 0 ... 40 mm
Linearity range: 1 ... 39 mm
Operating voltage: 12 ... 30 V DC (13 ... 30 V when analog voltage output is parameterized)
Reverse polarity protection: reverse polarity protected
Linearity error: within measuring range: ± 0.8 mm within linearity range: ± 0.4 mm
Repeat accuracy: ± 0.1 mm
Resolution: 50 µm
Temperature drift: ± 0.5 mm (-25 °C ... 70 °C)
No-load supply current: ≤ 40 mA
Operating voltage indicator: LED green
MTTFd: 382 a
Mission Time (TM): 20 a
Diagnostic Coverage (DC): 0 %
LED S1: switching state Switching output 1
LED S2: switching state Switching output 2
LED S3: Damping element in the configured analog measuring range
LED STATUS: Status display LED, green/red (Power on, communication/error, missing damping element)
Interface type: IO-Link (via C/Q = Pin 4)
IO-Link Revision: 1.1
Device profile: Smart Sensor
Device ID: 0x200204 (2097668)
Transfer rate: COM 2 (38.4 kBaud)
Value range: 0000h ... 3200h
Min. cycle time: 2.3 ms
Process data width: Process data input: 16 Bit Process data output: none
SIO mode support: yes
Compatible master port type: A
Output type: 2 push-pull outputs (can be parameterized), short-circuit-proof, reverse polarity protection, surge-proof
Operating current: ≤ 100 mA / output
Switching window: ± 1 mm
Switching hysteresis: 0.2 mm
Voltage drop: ≤ 3 V
Short-circuit protection: pulsing
Output type: 1 current output: 4 ... 20 mA or 1 voltage output: 0 ... 10 V , programmable
Load resistor: current output: ≤ 400 Ω voltage output: ≥ 1000 Ω
Short-circuit protection: voltage output: current limit
Standard conformity: Standards: EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 EN 60947-5-7:2003 EN61131-9:2013 IEC 60947-5-7:2003 IEC 61131-9:2013
UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure
Ambient temperature: -25 ... 85 °C (-13 ... 185 °F)
Connection type: 5-pin, M12 x 1 connector
Degree of protection: IP67 / IP69K
Material: Housing: PBT, stainless steel 1.4571 , brass, nickel-plated
Material: Target: mild steel, e. g. 1.0037, SR235JR (formerly St37-2)
Mass: 56 g
Equipment protection level: Gc (nA) , Dc
Type of protection: "n"
CE marking: [*PD-Z02586A*]
Certificates: ATEX certificate: PF 15 CERT 3754 X
Certificates: ATEX marking: II 3G Ex nA IIC T6 Gc
Certificates: Standards: EN 60079-0:2012+A11:2013 , EN 60079-15:2010
Possible characteristics: maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax
Maximum permissible ambient temperature: Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. mode of operation 1 at UBmax = 30 V and maximum 2 switching outputs with each ILmax =100 mA and 1 analog output with IAmax = 20mA or UAmax = 10 V : 30 °C (86 °F) mode of operation 2 at UBmax = 30 V and maximum 1 switching output with ILmax =100 mA : 50 °C (122 °F)
Type of protection: Protection by enclosure "tc"
CE marking: [*PD-Z02586A*]
Certificates: ATEX certificate: PF 15 CERT 3774 X
Certificates: ATEX marking: II 3D Ex tc IIIC T80°C Dc
Certificates: Standards: EN 60079-0:2012/A11+2013 , EN 60079-31:2014
Possible characteristics: maximum operating voltage UBmax , maximum load current ILmax , minimum series resistance RV , maximum analog output voltage UAmax , maximum analog output current IAmax
Maximum permissible ambient temperature: Also observe the maximum permissible ambient temperature stated in the general technical data. Keep to the lower of the two values. mode of operation 1 at UBmax = 30 V and maximum 2 switching outputs with each ILmax =100 mA and 1 analog output with IAmax = 20mA or UAmax = 10 V : 30 °C (86 °F) mode of operation 2 at UBmax = 30 V and maximum 1 switching output with ILmax =100 mA : 50 °C (122 °F)
Use in the hazardous area: see instruction manuals

Parametry logistyczne

ECCN:
Kraj pochodzenia: Singapur
EAN: 4050143052738
Waga: 0,08 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m