301160
NBB3-V3-Z4-2M
Inductive sensor
Series: Rectangular type, Housing material: PBT, Output type: 2-wire, Installation: flush, Type of voltage: DC, Connection type: cable PVC , 2 m, Degree of protection: IP67fa
Switching function: | Normally open (NO) |
Output type: | Two-wire |
Rated operating distance: | 3 mm |
Installation: | flush |
Output polarity: | DC |
Assured operating distance: | 0 ... 2.4 mm |
Actual operating distance: | 2.7 ... 3.3 mm typ. |
Reduction factor rAl: | 0.45 |
Reduction factor rCu: | 0.35 |
Reduction factor r304: | 0.8 |
Reduction factor rBrass: | 0.5 |
Output type: | 2-wire |
Operating voltage: | 5 ... 60 V DC |
Switching frequency: | 0 ... 2000 Hz |
Hysteresis: | typ. 0.2 mm |
Reverse polarity protection: | reverse polarity protected |
Short-circuit protection: | no |
Inductive overvoltage protection: | yes |
Voltage drop: | ≤ 4 V |
Voltage drop at IL: Voltage drop IL = 10 mA, switching element on: | 3.4 ... 3.9 V typ. 3.6 V |
Operating current: | 4 ... 100 mA |
Lowest operating current: | 4 mA |
Off-state current: | 0.4 ... 0.55 mA typ. 0.46 mA |
Time delay before availability: | ≤ 1 ms |
Switching state indicator: | LED, yellow |
Tightening torque, fastening screws: | 0.4 Nm |
MTTFd: | 1552 a |
Mission Time (TM): | 20 a |
Diagnostic Coverage (DC): | 0 % |
Standard conformity: Standards: | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
UL approval: | cULus Listed, General Purpose |
CSA approval: | cCSAus Listed, General Purpose |
CCC approval: | Certified by China Compulsory Certification (CCC) |
Ambient temperature: | -25 ... 85 °C (-13 ... 185 °F) |
Connection type: | cable PVC , 2 m |
Core cross-section: | 0.14 mm2 |
Housing material: | PBT |
Sensing face: | PBT |
Degree of protection: | IP67 |
Cable: Cable diameter: | 3 mm ± 0.2 mm |
Cable: Bending radius: | > 10 x cable diameter |
ECCN: | |
Kraj pochodzenia: | ID |
EAN: | |
Waga: | 0,00 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |