264991
VAA-2E1A-G10-SAJ/EA2J-2M-V1-G
AS-Interface Sicherheitsmodul VAA-2E1A-G10-SAJ/EA2J-2M-V1-G
The VAA-2E1A-G10-SAJ-*M-V1-G is an AS-Interface safety module with 2 safety-related inputs and one conventional output. A two-channel mechanical switch or a single channel mechanical switch each can be connected to the two safety-related inputs. The output is a conventional electronic non-safety-related output, which can be loaded with 50 mA. The module is suitable for remote connection of switches in very limited space. The onepiece housing provides a degree of protection of IP67 . The connection to the AS-Interface cable is achieved by means of insulation piercing method of the inserted flat cables. The inputs and the output are connected via an 8-pin M12 socket. To display the current switching state, there is a LED for each channel mounted on top of the module. A LED indicating the AS-Interface communication and the adress 0 of the module is also available. If a communication error occurs, the outputs are switched off (only at P0 = 1). The module can be used up to Category 4/PL e according to ISO 13849-1, SIL 3 according to EN 62061. If two single-channel switches are connected, the module can be used up to Category 2/ PL c according to ISO 13849-1, SIL 1 according to EN 62061.
Slave type: | Safety-Slave |
AS-Interface specification: | V3.0 |
Required master specification: | ≥ V2.1 |
UL File Number: | E223772 "For use in NFPA 79 Applications only" |
LED FLT: | error display; LED red red: communication error or address is 0 |
LED AS-i: | AS-Interface voltage; green LED green: voltage OK flashing green: address 0 |
LED IN: | switching state (input); 2 LED yellow |
LED OUT: | Switching state (output); LED yellow |
Rated operating voltage: | 26.5 ... 31.6 V from AS-Interface (PELV) |
Rated operating current: | ≤ 90 mA |
Protection class: | III |
Surge protection: | overvoltage category III |
Rated insulation voltage: | 32 V |
Pulse withstand voltage: | 0.8 kV |
Number/Type: | 2 safety-related inputs for mechanical contacts, crossed-circuit monitored: 2 single-channel contacts: up to category 2/PL c to ISO 13849-1 or 1 2-channel contact: up to category 4/PL e to ISO 13849-1 |
Supply: | from AS-Interface |
Voltage: | 20 ... 30 V DC pulsed |
Current: | input current limited ≤ 15 mA, short-circuit protected |
Number/Type: | 1 conventional electronic output, PNP |
Supply: | from AS-Interface |
Voltage: | (UASI - 7.0 V) ≤ UOUT ≤ UASI |
Current: | 50 mA , short-circuit/overload protected |
Electromagnetic compatibility: Directive 2014/30/EU: | EN 62026-2:2013 EN 61000-6-2:2005 EN 61000-6-4:2007 |
Machinery Directive: Directive 2006/42/EC: | EN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 |
Degree of protection: | EN 60529:2000 |
Fieldbus standard: | EN 62026-2:2013 |
Electrical safety: | IEC 61140:2009 |
Emitted interference: | EN 61000-6-4:2007 |
AS-Interface: | EN 62026-2:2013 |
Noise immunity: | IEC 62026-2:2013 EN 62061:2005 EN 61000-6-2:2005 |
Functional safety: | EN ISO 13849-1:2015 EN ISO 13849-2:2012 EN 62061:2005 + AC:2010 + A1:2013 + A2:2015 |
Profile: | S-7.B |
IO code: | 7 |
ID code: | B |
ID1 code: | F |
ID2 code: | 0 |
Data bits (function via AS-Interface): | input output |
Machinery Directive: D0: | dyn. safety code 1 OUT 1 |
Machinery Directive: D1: | dyn. safety code 1 - |
Machinery Directive: D2: | dyn. safety code 2 - |
Machinery Directive: D3: | dyn. safety code 2 - |
Parameter bits (programmable via AS-i): | function |
Machinery Directive: P0: | communication monitoring P0 = 1 (default settings), monitoring = ON, i.e. if communication fails, the outputs are de-energised P0 = 0, monitoring = OFF, if communication fails, the outputs maintain their condition |
Machinery Directive: P1: | not used |
Machinery Directive: P2: | not used |
Machinery Directive: P3: | not used |
UL approval: | cULus Listed, Type 1 enclosure |
Ambient temperature: | -20 ... 60 °C (-4 ... 140 °F) |
Storage temperature: | -25 ... 80 °C (-13 ... 176 °F) |
Relative humidity: | < 95 % |
Altitude: | ≤ 2000 m above MSL |
Shock and impact resistance: | 30 g, 11 ms in 6 spatial directions 3 shocks 10 g, 16 ms in 6 spatial directions 1000 shocks |
Vibration resistance: | 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles |
Pollution degree: | 3 |
Contact elements: | spring-loaded contact socket |
Degree of protection: | IP67 This protection class is achieved by using the AS-Interface flat cable VAZ-FK-S-YE |
Connection: | AS-Interface: AS-Interface flat cable Inputs/outputs: M12 x 1 socket, 8-pin |
Material: Contacts: | CuSn / Au |
Material: Contact surface: | Au |
Material: Housing: | PBT |
Material: Body: | TPU, black |
Material: Cable: | PUR |
Material: Slotted nut: | Diecast zinc |
Material: Mounting screw: | Stainless steel 1.4305 / AISI 303 |
Cable: Sheath diameter: | ∅4.8 mm |
Cable: Bending radius: | > 8 x cable diameter, fixed > 10 x cable diameter, moving not appropriate for conveyor chains |
Cable: Color: | black |
Cable: Cores: | 6 x 0.25 mm2 |
Cable: Length: | 2 m |
Mass: | 200 g |
Tightening torque, fastening screws: | 1.65 Nm |
Tightening torque, cable gland: | 0.4 Nm |
ECCN: | |
Kraj pochodzenia: | SG |
EAN: | |
Waga: | 0,00 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |