Pepperl+Fuchs 254910

LB8109H0906

Unicom Com Unit for PROFIBUS DP/DP-V1

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Interface between the I/O modules and the PCS/PLC, Com unit for 80 analog or 184 digital channels, Communication via PROFIBUS DP, Mounting in Zone 2, Class I/Div.2 or in the safe areapa. The PROFIBUS com unit forms the interface between the I/O modules on the backplane and the process control system. It supports all single width and dual width I/O modules. Thereby signals from NAMUR sensors, mechanical contacts, high-power solenoid drivers, power relays, sounders, and alarm LEDs are transported to the higher-level bus system. The com unit can be easily configured via DTM and supports redundancy as well as HART. Configuration in Run (CiR) enables configuration of a running system without a PROFIBUS restart, even in non-redundant systems.

Parametry techniczne

Connection: backplane bus
Rated voltage: 5 V DC , only in connection with the power supplies LB9***
Power dissipation: 1.8 W
Power consumption: 1.8 W
Fieldbus type: PROFIBUS DP/DP-V1
PROFIBUS DP: Connection: 9-pin Sub-D socket via backplane
PROFIBUS DP: Baud rate: up to 1.5 MBit/s
PROFIBUS DP: Protocol: PROFIBUS DP/DP V1 read/write services
Number of stations per bus line: max. 125 (PROFIBUS), max. 119 (service bus)
Cyclic process data: 240 bytes input and (simultaneously) 240 bytes output
Number of stations per bus segment: max. 31 (RS-485 standard)
Number of repeaters between Master and Slave: max. 3
Supported I/O modules: all LB remote I/O modules
Configuration (240 bytes I/O): Standard: 80 analog, 184 digital Universal 2I2O: 48 analog, 184 digital Universal 4I4O: 60 analog, 120 digital
Bus length: max. 1000 m (FOL, 1.5 MBaud), max. 1000 m (copper cable, 187.5 kBd), max. 200 m (copper cable, 1.5 MBd)
Addressing: via configuration software
PROFIBUS address: 0 ... 126 (factory standard setting: 126)
GSE file: CGV61710.gsd/gse
HART communication: via PROFIBUS or service bus
Connection: backplane bus
Redundancy: via backplane
LED indication: LED P: (power supply): On = operating, fast flash = cold start, slow flash = HCIR loading active LED 1: (collective alarm): On = internal fault, flashing = no PROFIBUS connection LED 2: (status fieldbus): flashing = PROFIBUS receive channel active LED 3: (status service bus): flashing = service bus receive channel active LED 4: (operating mode): flashing 1 (1:1 ratio) = active, normal operation; flashing 2 (7:1 ratio) = active, simulation LED 5: (status fieldbus): flashing = PROFIBUS response channel active LED 6: (status service bus): flashing = service bus response channel active
Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1
Electromagnetic compatibility: NE 21
Degree of protection: IEC 60529
Fieldbus standard: IEC 61158-2
Environmental test: EN 60068-2-14
Shock resistance: EN 60068-2-27
Vibration resistance: EN 60068-2-6
Damaging gas: EN 60068-2-42
Relative humidity: EN 60068-2-56
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
Storage temperature: -25 ... 85 °C (-13 ... 185 °F)
Relative humidity: 95 % non-condensing
Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Degree of protection: IP20 (module) , mounted on backplane
Connection: via backplane
Mass: approx. 120 g
Dimensions: 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch)
Certificate: PF 08 CERT 1234 X
Electromagnetic compatibility: Marking: II 3 G Ex nA IIC T4 Gc
Directive conformity: Directive 2014/34/EU: EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010
ATEX approval: PF 08 CERT 1234 X
UL approval: E106378
Directive conformity: Control drawing: 116-0321
Directive conformity: Approved for: cUL (Canada): CL I Zn. 2 IIC; IS circuits for CL I Zn. 0 IIC ULus (USA): CL I Div. 2 Grp. A, B, C, D; IS circuits for CL I, II, III Div. 1 Grp. A, B, C, D, E, F, G
IECEx approval: BVS 09.0037X
Directive conformity: Approved for: Ex nA IIC T4 Gc
EAC approval: Russia: RU C-IT.MIII06.B.00129
Marine approval: Lloyd Register: 15/20021
Marine approval: DNV GL Marine: TAA0000034
Marine approval: American Bureau of Shipping: T1450280/UN
Marine approval: Bureau Veritas Marine: 22449/B0 BV
System information: The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Parametry logistyczne

ECCN:
Kraj pochodzenia: Deutschland
EAN: 4050143064212
Waga: 0,15 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m