Pepperl+Fuchs 254808

LB5102A

Thermocouple Converter

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

1-channel, Input Ex ia, Mounting in Zone 2, Class I/Div.2 or in the safe area, Converter for thermocouples and mV-signalspa. The mV input accepts thermocouple or mV signals from the hazardous area. Open circuit line fault alarms are detected. The input is galvanically isolated from the bus and the power supply (EN 60079-11).

Parametry techniczne

Occupied slots: 1
Connection: backplane bus
Rated voltage: 12 V DC , only in connection with the power supplies LB9***
Power dissipation: 0.45 W
Power consumption: 0.45 W
Connection: backplane bus
Interface: manufacturer-specific bus to standard com unit
Compensation (reference junction CJC): internal cold junction compensation or external cold junction
Number of channels: 1
Suitable field devices: Field device [2]: Thermocouple
Suitable field devices: Field device [4]: mV source
Suitable sensors: Sensor: thermocouples U, B, E, T, K, S, R, L, J, N, Pallaplat and mV sources
Connection: cold junction: 1, 2 thermocouple: 5+, 6-
Measurement range: -75 ... mV ... 75 mV
Smallest span: 5 mV for 0.1 % accuracy
Linearity error: 0.1 %
Conversion time: internal cold junction: max. 120 ms without LFD max. 240 ms with LFD external cold junction: max. 20 ms without LFD max. 80 ms with LFD
Compensation (reference junction CJC): internal cold junction compensation or external cold junction
Line fault detection: can be switched on/off for each channel via configuration tool ,
Suitable sensors: Open-circuit: > 1 kΩ
Deviation: Influence of ambient temperature: max. 0,1 %/10 K
LED indication: Power LED (P) green: supply Status LED (1) red: line fault
Coding: optional mechanical coding via front socket
Electromagnetic compatibility: Directive 2014/30/EU: EN 61326-1
Electromagnetic compatibility: NE 21
Degree of protection: IEC 60529
Environmental test: EN 60068-2-14
Shock resistance: EN 60068-2-27
Vibration resistance: EN 60068-2-6
Damaging gas: EN 60068-2-42
Relative humidity: EN 60068-2-56
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
Storage temperature: -25 ... 85 °C (-13 ... 185 °F)
Relative humidity: 95 % non-condensing
Shock resistance: shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18
Vibration resistance: frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance
Damaging gas: designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3
Degree of protection: IP20 when mounted on backplane
Connection: removable front connector with screw flange (accessory) wiring connection via spring terminals (0.14 ... 1.5 mm2) or screw terminals (0.08 ... 1.5 mm2)
Mass: approx. 90 g
Dimensions: 16 x 100 x 102 mm (0.63 x 3.9 x 4 inch)
EU-type examination certificate: PTB 03 ATEX 2042 X
Electromagnetic compatibility: Marking: II (1) G [Ex ia] IIC II (1) D [Ex ia] IIIC
Input: Voltage: 1.8 V
Input: Current: 43 mA
Input: Power: 67 mW (trapezoid characteristic curve)
Certificate: PF 08 CERT 1234 X
Input: Marking: II 3 G Ex nA IIC T4 Gc
Galvanic isolation: Input/power supply, internal bus: safe electrical isolation acc. to EN 60079-11, voltage peak value 375 V
Directive conformity: Directive 2014/34/EU: EN 60079-0:2009 EN 60079-11:2007 EN 60079-15:2010 EN 61241-11:2006
ATEX approval: PTB 03 ATEX 2042 X
UL approval: E106378
Directive conformity: Control drawing: 116-0322
IECEx approval: BVS 09.0037X
Directive conformity: Approved for: Ex nA [ia Ga] IIC T4 Gc [Ex ia Da] IIIC
Marine approval: Lloyd Register: 15/20021
Marine approval: DNV GL Marine: TAA0000034
Marine approval: Bureau Veritas Marine: 22449/B0 BV
System information: The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure.
Supplementary information: EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com.

Parametry logistyczne

ECCN:
Kraj pochodzenia: Deutschland
EAN: 4050143074730
Waga: 0,11 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m