240736
NJ2-12GK-SN-0,3M 12xG1xxD
Inductive sensor
Series: Cylindrical type, Housing material: PP, Output type: 2-wire, Installation: flush, Type of voltage: DC, Connection type: cable silicone , 0.3 m, Degree of protection: IP68fa
| Switching function: | Normally closed (NC) |
| Output type: | NAMUR with safety function |
| Rated operating distance: | 2 mm |
| Installation: | flush |
| Assured operating distance: | 0 ... 1.62 mm |
| Reduction factor rAl: | 0.4 |
| Reduction factor rCu: | 0.3 |
| Reduction factor r304: | 0.85 |
| Safety Integrity Level (SIL): | up to SIL3 acc. to IEC 61508 Danger! In safety-related applications the sensor must be operated with a qualified fail safe interface from Pepperl+Fuchs, such as KFD2-SH-EX1. Consider the "exida Functional Safety Assessment" document which is available on www.pepperl-fuchs.com as an integral part of this product's documentation. |
| Output type: | 2-wire |
| Nominal voltage: | 8 V DC |
| Operating voltage: | 5 ... 25 V 1) |
| Switching frequency: | 0 ... 2000 Hz |
| Suitable for 2:1 technology: | yes , with reverse polarity protection diode |
| Current consumption: Measuring plate not detected: | ≥ 3 mA at nominal voltage |
| Current consumption: Measuring plate detected: | ≤ 1 mA at nominal voltage |
| Safety Integrity Level (SIL): | SIL 3 |
| MTTFd: | 7660 a |
| Mission Time (TM): | 20 a |
| Diagnostic Coverage (DC): | 0 % |
| Standard conformity: NAMUR: | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Standard conformity: Standards: | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
| FM approval: Control drawing: | 116-0165 |
| UL approval: | cULus Listed, General Purpose |
| FM approval: Ordinary Location: | E87056 |
| FM approval: Hazardous Location: | E501628 |
| FM approval: Control drawing: | 116-0454 |
| CSA approval: | cCSAus Listed, General Purpose |
| CCC approval: | CCC approval / marking not required for products rated ≤36 V |
| Ambient temperature: | -40 ... 100 °C (-40 ... 212 °F) |
| Connection type: | cable silicone , 0.3 m |
| Core cross-section: | 0.34 mm2 |
| Housing material: | PP |
| Sensing face: | PP |
| Degree of protection: | IP68 |
| Cable: Cable diameter: | 4.8 mm ± 0.2 mm |
| Cable: Bending radius: | > 10 x cable diameter |
| Use in the hazardous area: | see instruction manuals |
| ECCN: | |
| Kraj pochodzenia: | Indonesien |
| EAN: | 4050143037766 |
| Waga: | 0,02 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |