Pepperl+Fuchs 199785

GA18-S/GK18-S/59/115/161

Thru-beam sensor

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Thru-beam sensor, M18 threaded housing design, plastic housing, side optical face, 12 m detection range, red light, dark on, AC/DC version, NPN-FET output, fixed cable, Efficient Line in a short M18 plastic housing for standard applications, Very high detection range, 4 LEDs indicator for 360° visibility, Sidelookerversion, Universal usage at different power suppliesfa. The GLV/GLK18 series sensors help improve the efficiency of machines and systems. The design of the M18 plastic housing, the connection technology, and sensor properties are highly standardized. Concentrating on the key sensor requirements has produced a robust and reliable product series for DC and AC/DC voltage systems without any over-engineering. The mounting set included in the scope of delivery and the optimized potentiometer design ensure fast assembly and easy configuration.

Parametry techniczne

Emitter: GA18-S/115
Receiver: GK18-S/59/115/161
Effective detection range: 0 ... 12 m
Threshold detection range: 17.5 m
Light source: LED
Light type: modulated visible red light , 640 nm
Diameter of the light spot: approx. 650 mm at 17.5 m
Angle of divergence: approx. 2 °
Optical face: lateral
Ambient light limit: 30000 Lux
Accessories provided: Mounting aids
Operation indicator: LED green, statically lit Power on
Function indicator: Receiver: LED yellow, lights up when light beam is free, flashes when falling short of the stability control ; OFF when light beam is interrupted
Operating voltage: 20 ... 250 V AC/DC
No-load supply current: < 2.5 mA per device
Switching type: dark on
Signal output: N-channel MOSFET, short circuit protected
Switching voltage: max. 250 V AC/DC
Switching current: max. 200 mA
Voltage drop: ≤ 3.5 V AC/DC
Switching frequency: 50 Hz
Response time: ≤ 10 ms
Product standard: EN 60947-5-2
Standard conformity: Standards: UL 508
EAC conformity: TR CU 020/2011 TR CU 004/2011
Protection class: II, rated insulation voltage ≤ 250 V AC with pollution degree 1-2 according to IEC 60664-1
UL approval: cULus Listed, Type 1 enclosure For overcurrent protection, install a fuse with a rated current of max. 3 A 250 V AC/DC
CCC approval: Certified by China Compulsory Certification (CCC)
Ambient temperature: -20 ... 60 °C (-4 ... 140 °F)
Storage temperature: -40 ... 70 °C (-40 ... 158 °F)
Degree of protection: IP67
Connection: 2 m fixed cable
Material: Housing: ABS / PBT
Material: Optical face: PMMA
Mass: approx. 80 g per device

Parametry logistyczne

ECCN:
Kraj pochodzenia: VN
EAN:
Waga: 0,00 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m