106682
NJ20+U4+N 12xG1xxD
Inductive sensor
Series: VariKont ®, Housing material: PBT/metal, Output type: 2-wire, Installation: non-flush, Type of voltage: DC, Connection type: screw terminals, Degree of protection: IP68fa
| Switching function: | Normally closed (NC) |
| Output type: | NAMUR |
| Rated operating distance: | 20 mm |
| Installation: | non-flush |
| Assured operating distance: | 0 ... 16.2 mm |
| Reduction factor rAl: | 0.4 |
| Reduction factor rCu: | 0.3 |
| Reduction factor r304: | 0.85 |
| Output type: | 2-wire |
| Nominal voltage: | 8.2 V (Ri approx. 1 kΩ) |
| Switching frequency: | 0 ... 150 Hz |
| Current consumption: Measuring plate not detected: | ≥ 3 mA |
| Current consumption: Measuring plate detected: | ≤ 1 mA |
| Standard conformity: NAMUR: | EN 60947-5-6:2000 IEC 60947-5-6:1999 |
| Standard conformity: Standards: | EN 60947-5-2:2007 EN 60947-5-2/A1:2012 IEC 60947-5-2:2007 IEC 60947-5-2 AMD 1:2012 |
| FM approval: Control drawing: | 116-0165 |
| UL approval: Ordinary Location: | E87056 |
| UL approval: Hazardous Location: | E501628 |
| UL approval: Control drawing: | 116-0451 |
| CSA approval: | cCSAus Listed, General Purpose |
| CCC approval: | CCC approval / marking not required for products rated ≤36 V |
| Ambient temperature: | -25 ... 100 °C (-13 ... 212 °F) |
| Connection type: | screw terminals |
| Core cross-section: | ≤ 2.5 mm2 |
| Housing material: | PBT/metal |
| Sensing face: | PBT |
| Degree of protection: | IP68 |
| Use in the hazardous area: | see instruction manuals |
| ECCN: | |
| Kraj pochodzenia: | Indonesien |
| EAN: | 4050143009374 |
| Waga: | 0,29 kg |
| Długość: | 0,00 m |
| Szerokość: | 0,00 m |
| Wysokość: | 0,00 m |