Ifm TT0291

Temperature probe sensor. TT-100KFED06- /US/

Na prośbę. Prześlij nam wiadomość e-mail z zapytaniem o cenę i dostępność.
"ucnguBrctvdgcxgt0eqo"

Opis

Precise temperature measurement in containers, tanks and pipes. For the connection to an evaluation unit. Very short response time for use in processes with fast temperature fluctuations. Hygienic design for the requirements of the food and beverage industry. Variable process connection using adapters

Parametry techniczne

Measuring range: -40...150 °C -40...302 °F
-40...150 °C: -40...302 °F
Process connection: diameter Ø 6 mm
Installation length EL [mm]: 100
Special feature: Gold-plated contacts
Measuring element: 1 x Pt 100; (to DIN EN 60751, class A)
Application: hygienic systems
Media: liquids and gases
Pressure rating [bar]: 160
Minimum installation depth [mm]: 15
Protection class: III
Probe length L [mm]: 100
Measuring range: -40...150 °C -40...302 °F
-40...150 °C: -40...302 °F
Accuracy [K]: ± (0,15 K + 0,002 x |t|)
Dynamic response T05 / T09 [s]: 1 / 3; (to DIN EN 60751)
Ambient temperature [°C]: -25...80
Storage temperature [°C]: -40...100
Protection: IP 68; IP 69K
Shock resistance: DIN EN 60068-2-27 50 g (11 ms)
DIN EN 60068-2-27: 50 g (11 ms)
Vibration resistance: DIN EN 60068-2-6 10 g (10...2000 Hz)
DIN EN 60068-2-6: 10 g (10...2000 Hz)
MTTF [years]: 22831
Weight [g]: 31.8
Dimensions [mm]: Ø 6
Materials: stainless steel (1.4404 / 316L)
Materials (wetted parts): stainless steel (1.4404 / 316L) electropolished
Process connection: diameter Ø 6 mm
Surface characteristics Ra/Rz of the wetted parts: Ra: < 0.8
Probe diameter [mm]: 6
Installation length EL [mm]: 100
Remarks: operating voltage "supply class 2" according to cULus The values for accuracy apply to flowing water.
Pack quantity: 1 pcs.
Connection: Connector: 1 x M12; Contacts: gold-plated

Parametry logistyczne

ECCN:
Kraj pochodzenia: US
EAN:
Waga: 0,03 kg
Długość: 0,00 m
Szerokość: 0,00 m
Wysokość: 0,00 m