TK7310
Temperature switch with intuitive switch point setting. TK-050CLFN14-QSPKG / US
Simple switch point setting by means of two setting rings allowing optimum reading. Setting of the switch points without system temperature being applied. Two switching outputs with fixed hysteresis. Particularly good response dynamics and very short power-on delay time. Mechanical locking prevents inadvertent switch point manipulation
Number of inputs and outputs: | Number of digital outputs: 2 |
Measuring range: | -25...140 °C -13...284 °F |
-25...140 °C: | -13...284 °F |
Process connection: | threaded connection 1/4" NPT |
Installation length EL [mm]: | 50 |
Special feature: | Gold-plated contacts |
Measuring element: | 1 x Pt 1000; (to DIN EN 60751, class A) |
Media: | liquids and gases |
Medium temperature [°C]: | -40...145 |
Pressure rating [bar]: | 400 |
Operating voltage [V]: | 9.6...32 DC; ("supply class 2" to cULus) |
Current consumption [mA]: | < 30 |
Protection class: | III |
Reverse polarity protection: | yes |
Power-on delay time [s]: | 0.5 |
Number of inputs and outputs: | Number of digital outputs: 2 |
Total number of outputs: | 2 |
Output signal: | switching signal |
Electrical design: | PNP |
Number of digital outputs: | 2 |
Output function: | normally open |
Max. voltage drop switching output DC [V]: | 2 |
Permanent current rating of switching output DC [mA]: | 500 |
Short-circuit protection: | yes |
Type of short-circuit protection: | pulsed |
Overload protection: | yes |
Measuring range: | -25...140 °C -13...284 °F |
-25...140 °C: | -13...284 °F |
Set point SP: | -20...140 °C -4...284 °F |
-20...140 °C: | -4...284 °F |
Temperature drift per 10 K [K]: | 0.1 **) |
Repeatability [K]: | ± 0,1 |
Setting accuracy [K]: | ± 3 |
Dynamic response T05 / T09 [s]: | 1 / 3; (to DIN EN 60751) |
Adjustment of the switch point: | setting rings |
Ambient temperature [°C]: | -40...80 |
Note on ambient temperature: | at medium temperature: < 80 °C -40...50 °C at medium temperature: < 145 °C |
Storage temperature [°C]: | -40...100 |
Protection: | IP 67 |
EMC: | DIN EN 61000-4-2 ESD 4 kV CD / 8 kV AD EN 61000-4-3 HF radiated 10 V/m DIN EN 61000-4-4 Burst 2 kV EN 61000-4-6 HF conducted 10 V |
DIN EN 61000-4-2 ESD: | 4 kV CD / 8 kV AD |
EN 61000-4-3 HF radiated: | 10 V/m |
DIN EN 61000-4-4 Burst: | 2 kV |
EN 61000-4-6 HF conducted: | 10 V |
Shock resistance: | DIN IEC 68-2-27 50 g (11 ms) |
DIN IEC 68-2-27: | 50 g (11 ms) |
Vibration resistance: | DIN EN 60068-2-6 20 g (10...2000 Hz) |
DIN EN 60068-2-6: | 20 g (10...2000 Hz) |
MTTF [years]: | 643 |
UL approval: | UL Approval no. K018 |
UL Approval no.: | K018 |
Weight [g]: | 101 |
Materials: | stainless steel (1.4404 / 316L); PC; PBT; FKM |
Materials (wetted parts): | stainless steel (1.4404 / 316L); FKM |
Process connection: | threaded connection 1/4" NPT |
Probe diameter [mm]: | 6 |
Installation length EL [mm]: | 50 |
Display: | switching status 2 x LED, yellow |
switching status: | 2 x LED, yellow |
Remarks: | **) in case of deviation from the reference condition 25 °C The values for accuracy apply to flowing water. |
Pack quantity: | 1 pcs. |
Connection: | Connector: 1 x M12; Contacts: gold-plated |
ECCN: | |
Kraj pochodzenia: | US |
EAN: | |
Waga: | 0,10 kg |
Długość: | 0,00 m |
Szerokość: | 0,00 m |
Wysokość: | 0,00 m |